Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 25 - 25
1 Jan 2019
Jones P Woodgate S Williams D Biggs P Nicholas K Button K Corcoran P Holt C
Full Access

Whilst home-based exercise rehabilitation plays a key role in determining patient outcomes following orthopaedic intervention (e.g. total knee replacement), it is very challenging for clinicians to objectively monitor patient progress, attribute functional improvement (or lack of) to adherence/non-adherence and ultimately prescribe personalised interventions. This research aimed to identify whether 4 knee rehabilitation exercises could be objectively distinguished from each other using lower body inertial measurement units (IMUs) and principle components analysis (PCA) in the hope to facilitate objective home monitoring of exercise rehabilitation.

5 healthy participants performed 4 repetitions of 4 exercises (knee flexion in sitting, knee extension, single leg step down and sit to stand) whilst wearing lower body IMU sensors (Xsens, Holland; sampling at 60 Hz). Anthropometric measurements and a static calibration were combined to create the biomechanical model, with 3D hip, knee and ankle angles computed using the Euler sequence ZXY. PCA was performed on time normalised (101 points) 3D joint angle data which reduced all joint angle waveforms into new uncorrelated PCs via an orthogonal transformation. Scatterplots of PC1 versus PC2 were used to visually inspect for clustering between the PC values for the 4 exercises. A one-way ANOVA was performed on the first 3 PC values for the 9 variables under analysis. Games-Howell post hoc tests identified variables that were significantly different between exercises.

All exercises were clearly distinguishable using the PC scatterplot representing hip flexion-extension waveforms. ANOVA results revealed that PC1 for the knee flexion angle waveform was the only PC value statistically different across all exercises.

Findings demonstrate clear potential to objectively distinguish between different knee rehabilitation exercises using IMU sensors and PCA. Flexion-extension angles at the hip and knee appear most suited for accurate separation, which will be further investigated on patient data and additional exercises.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_11 | Pages 32 - 32
1 Oct 2015
Chauhan A Morrissey D Jones P Angioi M Kumar B Langberg H Maffulli N Malliaras P
Full Access

Introduction

Achilles tendinopathy (AT) is a highly prevalent injury in athletes and non-athletes with an unknown aetiology. Genetic risk factors have been a recent focus of investigation. The aim of this systematic review was to determine which loci have been linked with mid-portion AT and could potentially be used as biomarkers in tendinopathy risk models or as preventative or therapeutic targets.

Materials and Methods

Eight electronic bibliographic databases were searched from inception to April 2015 for cross-sectional, prospective cohort and case-control studies that included empirical research investigating genes associated with mid-portion AT. Potential publications were assessed by two independent reviewers (AAC and PRJ) for inclusion and quality. Quality was evaluated using a validated scale.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_17 | Pages 27 - 27
1 Apr 2013
Owen SJ Roberts S Eisenstein S Jones P Sharp CA
Full Access

Background

Intervertebral disc cells exist in a challenging physiological environment. Disc degeneration occurs early in life implying that disc cells may no longer be able to maintain a functional tissue. We hypothesise that disc cells have a stress response different from most other cells because of the disc environment. We have compared the stress response of freshly isolated and cultured bovine nucleus pulposus (NP) cells with bovine dermal fibroblasts, representative of cells from a vascularised tissue.

Methods

Freshly isolated and passaged bovine NP cells and dermal fibroblasts were cultured for 3 days then subjected to either thermal stress at 45°C for 1h followed by recovery times of 6, 24 and 48h or nutrient stress involving culture without serum for 6, 24 and 48 h. At each time point, cell number and viability were assessed and heat shock protein 70 (Hsp70) measured in cell lysates by an enzyme-linked immunosorbent assay.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 69 - 69
1 Aug 2012
Picardo N Nawaz Z Gallagher K Whittingham-Jones P Parratt T Briggs T Carrington R Skinner J Bentley G
Full Access

The aim of this study was to determine whether the clinical outcome of autologous chondrocyte transplantation was dependent on the timing of a high tibial osteotomy in tibio-femoral mal-aligned knees. Between 2000 and 2005, forty-eight patients underwent autologous chondrocyte implantation with HTO performed at varying times relative to the second stage autologous chondrocyte implantation procedure. 24 patients had HTO performed simultaneously with their second stage cartilage transplantation, (the HTO Simultaneous Group). 5 patients had HTO prior to their cartilage procedure, (the HTO pre-ACI Group) and 19 had HTO performed between 1 to 4 years after their second stage cartilage implantation, (the HTO post-ACI Group). There were 29 men and 19 women with a mean age of 37 years (Range 28 to 50) at the time of their second stage procedure.

With average follow-up of 72 months we have demonstrated a significant functional benefit in performing the HTO either prior to or simultaneously with the ACI procedure in the mal-aligned knee. The failure rate in the Post-ACI group was 45% compared to the Pre-ACI and Simultaneous group, with failure rates of 20% and 25%, respectively.

An HTO performed prior to or simultaneously with an autologous chondrocyte implantation procedure in the mal-aligned knee, provides a significant protective effect by reducing the failure rate by approximately 50%.