Hanberg P Bue M Kabel J Jrgensen AR Jessen C S⊘balle K Stilling M
Full Access

Tourniquet is widely used in orthopedic surgery to reduce intraoperative bleeding and improve visualization. We evaluated the effect of tourniquet application on both peri- and postoperative cefuroxime concentrations in subcutaneous tissue, skeletal muscle, calcaneal cancellous bone, and plasma. The primary endpoint was the time for which the free drug concentration of cefuroxime was maintained above the clinical breakpoint minimal inhibitory concentration (T>MIC) forStaphylococcus aureus (4 µg/mL).

Ten patients scheduled for hallux valgus or hallux rigidus surgery were included. Microdialysis catheters were placed for sampling of cefuroxime concentrations bilaterally in subcutaneous tissue, skeletal muscle, and calcaneal cancellous bone. A tourniquet was applied on the thigh of the leg scheduled for surgery. Cefuroxime (1.5 g) was administered intravenously as a bolus 15 minutes prior to tourniquet inflation, followed by a second dose 6 hours later. The mean tourniquet duration (range) was 65 (58; 77) minutes. Dialysates and venous blood samples were collected for 12 hours.

For cefuroxime the T>MIC (4 μg/mL) ranged between 4.8–5.4 hours across compartments, with similar results for the tourniquet and non-tourniquet leg. Comparable T>MIC and penetration ratios were found for the first and second dosing intervals.

We concluded that administration of cefuroxime (1.5 g) 15 minutes prior to tourniquet inflation is safe in order to achieve tissue concentrations above 4 µg/mL throughout surgery. A tourniquet application time of approximately 1 hour did not affect the cefuroxime tissue penetration in the following dosing interval.