header advert
Results 1 - 1 of 1
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 2 - 2
1 Jun 2012
Ellapparadja P Husami Y McLeod I
Full Access

The posterolateral approach to ankle joint is well suited for ORIF of posterior malleolar fractures. There are no major neurovascular structures endangering this approach other than the sural nerve. The sural nerve is often used as an autologous peripheral nerve graft and provides sensation to the lateral aspect of the foot. Hence every attempt must be made to protect the sural nerve. The aim of this paper is to measure the precise distance of the sural nerve from surrounding soft tissue structures.

This is a retrospective image review study including patients with MRI of their ankle from January 09 - Nov 2010. We indentified 78 MRI scans out of which 64 were deemed eligible for assessment. All measurements were made from Axial T1 slices. Measurements were made from the lateral aspect of the TA to the central of the sural nerve, central of sural nerve to the posterior aspect of the peronei muscles and central of the sural nerve to the posterior aspect of fibula. Data were collected on a Microsoft Excel spreadsheet and the descriptive statistics calculated.

The key findings of the paper is the safety window for the sural nerve from the lateral border of TA is 7mm, 1.3cm and 2cm at 3 cm above ankle joint, at the ankle joint and at the distal tip of fibula respectively. Similarly the safety window for the nerve from the posterior aspect of fibula is 2cm, 1.6cm, 1.6cm at 3cm above ankle, at the ankle joint and the distal tip of fibula respectively.

Our study demonstrates the close relationship of the nerve in relation to tendoachilles, peronei and fibula in terms of exact measurements. The safety margins established in this study should enable the surgeon in preventing endangerment of the sural nerve encountered in this approach.