header advert
Results 1 - 4 of 4
Results per page:
Applied filters
Research

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 62 - 62
17 Nov 2023
Lan T Wright K Makwana N Bing A McCarthy H Hulme C
Full Access

Abstract

Objectives

Bone marrow aspirate concentrate (BMAC), together with fibrin glue (Tisseel, Baxter, UK) and Hyaluronic acid (HA) were used as a one-step cell therapy treating patients with ankle cartilage defects in our hospital. This therapy was proven to be safe, with patients demonstrating a significant improvement 12 months post-treatment. Enriched mesenchymal stem cells (MSCs) in BMAC are suggested inducers of cartilage regeneration, however, currently there is no point-of-care assessment for BMAC quality; especially regarding the proportion of MSCs within. This study aims to characterise the cellular component of CCR-generated BMAC using a point-of-care device, and to investigate if the total nucleated cell (TNC) count and patient age are predictive of MSC concentration.

Methods

During surgery, 35ml of bone marrow aspirate (BMA) was collected from each patients’ iliac crest under anaesthesia, and BMAC was obtained via a commercial kit (Cartilage Regeneration kit, CCR, Innotec®, UK). BMAC was then mixed with thrombin (B+T) for injection with HA and fibrinogen. In our study, donor-matched BMA, BMAC and B+T were obtained from consented patients (n=12, age 41 ± 16years) undergoing surgery with BMAC therapy. TNC, red blood cell (RBC) and platelet (PLT) counts were measured via a haematology analyser (ABX Micros ES 60, Horiba, UK), and the proportion of MSCs in BMA, BMAC and B+T were assessed via colony forming unit-fibroblast (CFU-F) assays. Significant differences data in matched donors were tested using Friedman test. All data were shown as mean ± SD.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 53 - 53
17 Nov 2023
Wright K McDonald J Mennan C Perry J Peffers M Hulme C
Full Access

Abstract

Objectives

A promising therapy for early osteoarthritis (OA) is the transplantation of human umbilical cord-derived mesenchymal stromal cells (hUC-MSCs). The synovial fluid (SF) from a pre-clinical ovine model treated with hUC-MSCs has been profiled using proteomics and bioinformatics to elucidate potential mechanisms of therapeutic effect.

Methods

Four weeks after a medial meniscus transection surgery, sheep were injected with 107 hUC-MSCs in Phosphate Buffered Saline (PBS) or PBS only (n=7) and sacrificed at 12 weeks. SF was normalised for protein abundance (ProteoMinerTM) and analysed using label-free quantitation proteomics. Bioinformatics analyses (Ingenuity Pathway Analysis (IPA) and STRING) were used to assess differentially regulated functions from the proteomic data. Human orthologues were identified for the ovine proteins using UniProt and DAVID resources and proteins that were ≥±1.3 fold differentially abundant between treatment groups, were included in the bioinformatics analyses.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 76 - 76
17 Apr 2023
Hulme C Roberts S Gallagher P Jermin P Wright K
Full Access

Stratification is required to ensure that only those patients likely to benefit, receive Autologous Chondrocyte Implantation (ACI); ideally by assessing a biomarker in the blood. This study aimed to assess differences in the plasma proteome of individuals who respond well or poorly to ACI.

Isobaric tag for relative and absolute quantitation (ITRAQ) mass spectrometry and label-free proteomics analyses were performed in tandem as described previously by our group (Hulme et al., 2017; 2018; 2021) using plasma collected from ACI responders (n=10) compared with non-responders (n=10) at each stage of surgery (Stage I, cartilage harvest and Stage II, cell implantation).

iTRAQ using pooled plasma detected 16 proteins that were differentially abundant at baseline in ACI responders compared with non-responders (n=10) (≥±2.0 fold; p<0.05). Responders demonstrated a mean Lysholm (patient reported functional score from 0–100) improvement of 33±13 and non-responders a mean worsening of −13±13 points. The most pronounced plasma proteome shift was seen in response to Stage I surgery in ACI non-responders, with 48 proteins being differentially abundant between the two surgical procedures. We have previously noted this marked shift in response to initial surgery in the SF of ACI non-responders, several of these proteins were associated with the Acute Phase Response. One of these proteins, clusterin, could be confirmed in patients’ plasma using an independent immunoassay using individual samples. Label-free proteomic data from individual samples identified only cartilage acidic protein-1 (known to associate with osteoarthritis progression) to be significantly more abundant at Stage I in the plasma of non-responders.

This study indicates that proteins can be identified within the plasma that have potential use in ACI patient stratification. Further work is required to validate the findings of this discovery-phase work in larger ACI cohorts.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 11 - 11
1 Dec 2021
Hulme C Gallacher P Jermin P Roberts S Wright K
Full Access

Abstract

Purpose

Stratification is required to ensure that only patients likely to benefit, receive Autologous Chondrocyte Implantation (ACI). At Stage I (SI), healthy cartilage is harvested from the joint and chondrocytes culture expanded before being implanted into a chondral/osteochondral defect at Stage II (SII). In ACI non-responders, there is a marked shift in the profile and abundance of proteins detectable in the synovial fluid (SF) at SII, many being associated with an acute phase response (APR). However, clinical biomarkers are easier to measure in blood than SF, so we have now performed this investigation in plasma.

Methods

Isobaric tag for relative and absolute quantitation mass-spectrometry was used to assess the proteome in plasma pooled from ACI responders (mean Lysholm improvement of 33, n=10) or non-responders (mean: −13 points, n=10), collected at SI or SII surgeries. Interactome networks were generated using STRING. Plasma proteome data were compared to matched SF data, previously analysed, to identify any proteins that changed across the fluids. Clusterin concentration was quantitated (ELISA; Biotechne).