Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 47 - 47
19 Aug 2024
Dimitriou D Almazrua I Alhasson M Staunton P Zukor D Huk O Antoniou J
Full Access

Short stems have been developed to conserve bone stock, especially in younger populations undergoing a total hip arthroplasty (THA), and showed similar functional outcomes compared to conventional stems. Recent literature suggested that stem length might be an independent risk factor for acute periprosthetic femoral fracture in direct anterior THA (1) or with different short stem designs (2). The purpose of the present study was to compare the incidence of acute periprosthetic femoral fractures, between stems of the same manufacture (Taperloc microplasty vs Taperloc complete), which have the same stem characteristics, except for the stem length which is 35 mm shorter in Taperloc microplasty during posterior and lateral THA.

Our institution's arthroplasty database was searched for all primary total hip arthroplasties utilizing short femoral stems performed between August 2016 and August 2023. Pre-operative X-rays for each case were analysed to characterize the proximal femoral geometry, specifically the canal bone ratio (CBR) and canal flare index (CFI). Data analysis was performed to identify risk factors for periprosthetic fractures.

For the time period assessed, 2107 femoral stems (Taperloc Microplasty:1727, Taperloc complete: 380) were implanted. Females constituted 53% of the cohort. The average patient age was 70±11 years. The periprosthetic fracture rate was 0.94%, with 20 periprosthetic fractures (Taperloc Microplasty:17, Taperloc complete: 3) excluding 2 greater trochanteric fractures (1 at each group), identified at follow-up of three months. There was no significant difference between the periprosthetic fracture rates between the two stems (0.98% vs 0.79%, p>0.72) The multivariate regression analysis demonstrated that the stem length, CBR, CFI, age, and gender were not risk factors for periprosthetic fracture.

The present study demonstrated that both Taperloc Microplasty and Taperloc complete stems had similar rates of periprosthetic fractures, and the stem length was not a risk factor for a periprosthetic fracture during uncemented THA.

1. Tamaki T, Cementless Tapered-Wedge Stem Length Affects the Risk of Periprosthetic Femoral Fractures in Direct Anterior Total Hip Arthroplasty. J Arthroplasty. 2018 Mar;33(3):805-809. 2. Staunton P. Acute Periprosthetic Hip Fracture with Short Uncemented Femoral Stems. J Arthroplasty 2024 accepted.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 30 - 30
1 Oct 2019
Antoniou J Gomes SK Zukor D Huk O Bergeron S Robbins SM
Full Access

Introduction

Gluteus medius is disrupted during lateral approach total hip arthroplasty (THA) which may impact its function and ability to control the pelvis. The objective was to compare gluteus medius activation and joint mechanics associated with a Trendelenburg sign (pelvic drop, trunk lean) during gait and hip abductor strength between patients that underwent lateral or posterior THA approaches one year post-surgery and healthy adults.

Methods

Participants that underwent primary THA for hip osteoarthritis using lateral (n=21) or posterior (n=21) approaches, and healthy adults (n=21) were recruited for this cross-sectional study. Participants completed five walking trials. Surface electromyography captured gluteus medius activation. A 3-dimensional optical motion capture system measured frontal plane pelvic obliquity and lateral trunk lean angles. Participants performed maximum voluntary isometric contractions (MVIC) on a dynamometer to measure hip abductor torque. Characteristics from gait waveforms were identified using principal component analysis, and participant waveforms were scored against these characteristics to produce principal component scores. One-way analysis of variance and effect sizes (d) compared gait principal component scores and isometric hip abductor torque between groups.