header advert
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 6 - 6
1 Feb 2021
Madurawe C Vigdorchik J Lee G Jones T Dennis D Austin M Pierrepont J Huddleston J
Full Access

Introduction

Excessive standing posterior pelvic tilt (PT), lumbar spine stiffness, low pelvic Incidence (PI), and severe sagittal spinal deformity (SSD) have been linked to increased dislocation rates. We aimed to compare the prevalence of these 4 parameters in unstable and stable primary Total Hip Arthroplasty (THA) patients.

Methods

In this retrospective cohort study, 40 patients with instability following primary THA for osteoarthritis were referred for functional analysis. All patients received lateral X-rays in standing and flexed seated positions to assess functional pelvic tilt and lumbar lordosis (LL). Computed tomography scans were used to measure pelvic incidence and acetabular cup orientation. Literature thresholds for “at risk” spinopelvic parameters were standing pelvic tilt ≤ −10°, lumbar flexion (LLstand – LLseated) ≤ 20°, PI ≤ 41°, and sagittal spinal deformity (PI – LLstand mismatch) ≥ 10°. The prevalence of each risk factor in the dislocation cohort was calculated and compared to a previously published cohort of 4042 stable THA patients.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 65 - 65
1 Apr 2019
Mooney J Huddleston J Amanatullah D
Full Access

Computer-assisted orthopaedic surgery (CAOS) improves mechanical alignment and the accuracy of surgical cuts in the context of total knee arthroplasty. A simplified, CAOS enhanced instrumentation system was assessed to determine if the same effects could be achieved through the use of a less intrusive system. Two cohorts of surgeons (experienced and trainees) performed a series of total knee arthroplasty resections in knee models with and without navigation-enhanced instrumentation. The percentage of resections that deviated from the planned cut by more than 2°or 2mm (outliers) was determined by post-resection advanced imaging for six unique outcome metrics. Within each experience level, the use of the CAOS enhanced system significantly reduced the total percentage of outliers as compared to conventional instrumentation (Figure 1). The experienced users improved from 35% to 4% outliers overall (p < .001) and the trainees from 34% to 10% outliers (p < .001). Comparing across experience levels, the experienced surgeons performed significantly better in only a single resection metric with conventional instrumentation (Figure 2A), varus/valgus tibial alignment, with 8.3% outliers compared to the trainee's 63% outliers (p = .004). The use of CAOS enhanced instrumentation eliminated any differences between the two user groups for all measured resections (Figure 2B). Comparing CAOS enhanced to conventional instrumentation specifically between anatomical deformity types revealed that there is significant improvement (p < .05) with the use of enhanced instrumentation for all three deformity types (Figure 3). These results suggest that non-intrusive CAOS enhanced instrumentation is a viable alternative to conventional instrumentation with possible benefits. This trial also demonstrates that additional experience may not correlate to improved surgical accuracy, and outliers may be less a result of individual surgeon ability or specific anatomic deformities, and more so related to limitations of the instrumentation used or other yet unidentified factors.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 20 - 20
1 Mar 2017
Dai Y Bertrand F Angibaud L Hamad C Jung A Liu D Huddleston J Stulberg B
Full Access

INTRODUCTION

Despite that computer-assisted orthopaedic surgery (CAOS) has been shown to offer increased accuracy to the bony resections compared to the conventional techniques [1], previous studies of CAOS have mostly focused on alignment outcomes based on a small number of patients [1]. Although several recent meta-analyses on the CAOS outcomes have been reported [2], these analyses did not differentiate between systems, while system-dependency has been reported to influence alignment parameters [3]. To date, no study has benchmarked a specific CAOS system based on a large number of clinical cases. The purpose of this study is to assess the accuracy and precision of bony resection in more than 4000 cases using a specific contemporary CAOS system.

Materials and Methods

Technical logs of 4292 TKAs performed between October 2012 and January 2016 using a contemporary CAOS system (ExactechGPS, Blue-Ortho, Grenoble, FR) were analyzed. The analyses were performed on: 1) planned resection, defined by the surgeon prior to the bone cuts. These parameters serve as inputs for the CAOS guidance; and 2) Checked resection, defined as digitalization of the actual resection surfaces by manually pressing an instrumented checker onto the bony cuts. Deviations in alignment and resection depths (on the referenced side) between planned and checked resections were calculated in coronal and sagittal planes for both tibia and femur (planned vs checked).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 19 - 19
1 Mar 2017
Dai Y Angibaud L Jung A Hamad C Bertrand F Huddleston J Stulberg B
Full Access

INTRODUCTION

Although several meta-analyses have been performed on total knee arthroplasty (TKA) using computer-assisted orthopaedic surgery (CAOS) [1], understanding the inter-site variations of the surgical profiles may improve the interpretation of the results. Moreover, information on the global variations of how TKA is performed may benefit the development of CAOS systems that can better address geographic-specific operative needs. With increased application of CAOS [2], surgeon preferences collected globally offers unprecedented opportunity to advance geographic-specific knowledge in TKA. The purpose of this study was to investigate geographic variations in the application of a contemporary CAOS system in TKA.

Materials and Methods

Technical records on more than 4000 CAOS TKAs (ExactechGPS, Blue-Ortho, Grenoble, FR) between October 2012 and January 2016 were retrospectively reviewed. A total of 682 personalized surgical profiles, set up based on surgeon's preferences, were reviewed. These profiles encompass an extensive set of surgical parameters including the number of steps to be navigated, the sequence of the surgical steps, the definition of the anatomical references, and the parameters associated with the targeted cuts. The profiles were compared between four geographic regions: United States (US), Europe (EU), Asia (AS), and Australia (AU) for cruciate-retaining (CR) and posterior-stabilized (PS) designs. Clinically relevant statistical differences (CRSD, defined as significant differences in means ≥1°/mm) were identified (significance defined as p<0.05).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 82 - 82
1 Feb 2017
Courtney P Huddleston J Iorio R Markel D
Full Access

Introduction

Alternative payment models, such as bundled payments, aim to control rising costs for total knee (TKA) and total hip arthroplasty (THA). Without risk adjustment for patients who may utilize more resources, concerns exist about patient selection and access to care. The purpose of this study was to determine whether lower socioeconomic status (SES) was associated with increased resource utilization following TKA and THA.

Methods

Using the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) database, we reviewed a consecutive series of 4,168 primary TKA and THA patients over a 3-year period. We defined lowest SES based upon the median household income of the patient's ZIP code. An a prioripower analysis was performed to determine the appropriate sample size. Demographics, medical comorbidities, length of stay, discharge destination, and readmission rates were compared between patients of lowest SES and higher SES.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 90 - 90
1 Feb 2017
Dai Y Angibaud L Jung A Hamad C Bertrand F Stulberg B Huddleston J
Full Access

INTRODUCTION

Studies have reported that only 70–80% of the total knee arthroplasty (TKA) cases using conventional instruments can achieve satisfactory alignment (within ±3° of the mechanical axis). Computer-assisted orthopaedic surgery (CAOS) has been shown to offer increased accuracy and precision to the bony resections compared to conventional techniques [1]. As the early adopters champion the technology, reservation may exist among new CAOS users regarding the ability of achieving the same results. The purpose of this study was to investigate if there are immediate benefits in the accuracy and precision of achieving surgical goals for the novice surgeons, as compared to the experienced surgeons, by using a contemporary CAOS system.

Materials and Methods

Two groups of surgeons were randomly selected from TKAs between October 2012 and January 2016 using a CAOS system (ExactechGPS, Blue-Ortho, Grenoble, FR), including:

Novice group (7 surgeons): no navigation experience prior to the adoption of the system and have performed ≤20 CAOS TKAs. To investigate the intra-group variation, this group was further divided into surgeons with extensive experience in conventional TKA (novice-senior), and surgeons who were less experienced (novice-junior).

Experiences group (6 surgeons): used the CAOS system for more than 150 TKAs.

All the surgeries from the novice group (86 cases) and the most recent 20 cases from each surgeon in the experienced group (120 cases) were studied. Deviations in the resection parameters between the following were investigated for both tibia and femur: 1) planned resection, resection goals defined prior to the bone cuts; 2) checked resection, digitization of the realized bone cuts. The deviations were compared within the novice group (novice-senior vs novice-junior), as well as between the novice and experience groups. Knees with optimal resection (deviation<2°/mm, without clinically alter the joint mechanics [2]) and acceptable resection (deviation<3°/mm, as commonly adopted) were identified. Significance was defined as p<0.05.