Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 37 - 37
1 Jan 2013
Bayley E Brown S Howard P
Full Access

Aim

To assess the incidence of fatal pulmonary embolism (PE) following elective total knee replacement (TKR) with a standardised multi-modal prophylaxis regime in a large teaching DGH over a 10 year period.

Material and methods

Information was gathered from a prospective audit database, utilising clinical coding for TKR and those that had died within 42 and 90 days. The 10 years from April 2000 were analysed to establish both 42 and 90 day mortality rates.

A multi-modal prophylaxis regime for all patients included regional anaesthesia (when possible), mechanical prophylaxis (Flo-tron calf garment per-operatively, AV impulse boots until mobile and anti-embolism stockings for 6 weeks), mobilisation within 24 hours and 75mg aspirin for 4 weeks.

A case note review was performed to ascertain the causes of death. Where a patient had been referred to the coroner, the coroner's office was contacted for PM results.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 12 - 12
1 Mar 2012
Wraighte P Howard P
Full Access

Femoral impaction grafting with cancellous bone and cement is an important technique in reconstituting deficient bone stock in revision hip arthroplasty. We report the medium to long term results of 75 consecutive patients using a collarless, polished, tapered femoral stem with an average age of 68 (±11.4) years and a mean follow up of 10.5 (±2.4) years (range 6.3 to 14.1 years).

The median Endoklinik pre-operative bone defect score was 3 (IQR: 2–3) with a median subsidence at 1 year of 2mm (IQR: 1–3mm). At the most recent follow-up (mean 10.5±2.4 years), the median Harris Hip Score (HHS) was 80.6 (IQR: 67.6–88.9) and median subsidence 2mm (IQR: 1–4mm). Ten-year survivorship with any further femoral operation as an endpoint was 92%. Four prostheses required further revision.

Subsidence of the Exeter stem continued, albeit at a slower rate after the first year and was related to the Endoklinik pre-operative bone loss (p=0.037). The degree of subsidence at 1 year was a strong predictor of long term subsidence (p<0.001). Neither subsidence nor bone stock were related to long term outcome (HHS). There was a correlation between previous revision surgery and a poor Harris Hip Score (p=0.028) and those who had undergone previous revision surgery for infection had a higher risk of complications (p=0.048).

The good long term results of this technique commend its use in revision hip arthroplasty for patients with poor femoral bone stock.