Vol. 105-B, Issue SUPP_2 | Pages 96 - 96
10 Feb 2023
Blundell J Hope M
Full Access

Patients awaiting resolution of swelling and oedema prior to ankle surgery can represent a significant burden on hospital beds. Our study assessed whether external pneumatic intermittent compression (EPIC) can reduce delays to surgery.

Our prospective randomised controlled trial (n= 20) compared outcomes of patients treated with EPIC vs control group managed with ice and elevation. Included were patients aged <18 years with isolated closed ankle fractures admitted for management of swelling prior to surgery. Excluded were open fractures, injuries to contralateral leg, diabetes, absent pulses, peripheral vascular disease, inability to consent, no requirement for admission. Eligible patients were randomised to active or control arms. All patients were managed initially with reduction and back slab application. Patients in active arm fitted with EPIC (Hydroven 3000) device over the back slab. Assessment by treating team determined the time at which patient is assessed ready for surgery.

Patients in the treatment arm were assessed as ready for surgery sooner, (123 hrs vs 168hrs, T score = 1.925, P 0.035) and had a shorter time to surgery (167 hrs vs 216 hrs, T score = 1.748, P 0.047) Length of stay was reduced bud did not reach statistical significance. (259 hrs vs 269 hrs, T score 0.229, P 0.41)

Our results showed a statistically and clinically significant reduction in time that patients were assessed ready for surgery and time to surgery in the treatment cohort. We conclude that although further data is needed to achieve an adequately powered study and assess the safety profile of the EPIC, incorporation of EPIC into routine clinical practice has the potential for significant cost savings.