Revision surgeries for orthopaedic infections are done in two stages – one surgery to implant an antibiotic spacer to clear the infection and another to install a permanent implant. A permanent porous implant, that can be loaded with antibiotics and allow for single-stage revision surgery, will benefit patients and save healthcare resources. Gyroid structures can be constructed with high porosity, without stress concentrations that can develop in other period porous structures [1] [2]. The purpose of this research is to compare the resulting bone and prosthesis stress distributions when porous versus solid stems are implanted into three proximal humeri with varying bone densities, using finite element models (FEM). Porous humeral stems were constructed in a gyroid structure at porosities of 60%, 70%, and 80% using computer-aided design (CAD) software. These CAD models were analyzed using FEM (Abaqus) to look at the stress distributions within the proximal humerus and the stem components with loads and boundary conditions representing the arm actively maintained at 120˚ of flexion. The stem was assumed to be made of titanium (Ti6Al4V). Three different bone densities were investigated, representing a healthy, an osteopenic, and an osteoporotic humerus, with an average bone shape created using a statistical shape and density model (SSDM) based on 75 cadaveric shoulders (57 males and 18 females, 73 12 years) [3]. The Young's moduli (E) of the cortical and trabecular bones were defined on an element-by-element basis, with a minimum allowable E of 15 MPa. The Von Mises stress distributions in the bone and the stems were compared between different stem scenarios for each bone density model. A preliminary analysis shows an increase in stress values at the proximal-lateral region of the humerus when using the porous stems compared to the solid stem, which becomes more prominent as bone density decreases. With the exception of a few mesh dependent singularities, all three porous stems show stress distributions below the fatigue strength of Ti-6Al-4V (410 MPa) for this loading scenario when employed in the osteopenic and osteoporotic humeri [4]. The 80% porosity stem had a single strut exceeding the fatigue strength when employed in the healthy bone. The results of this study indicate that the more compliant nature of the porous stem geometries may allow for better load transmission through the proximal humeral bone, better matching the stress distributions of the intact bone and possibly mitigating stress-shielding effects. Importantly, this study also indicates that these porous stems have adequate strength for long-term use, as none were predicted to have catastrophic failure under the physiologically-relevant loads. Although these results are limited to a single boney geometry, it is based on the average shape of 75 shoulders and different bone densities are considered. Future work could leverage the shape model for probabilistic models that could explore the effect of stem porosity across a broader population. The development of these models are instrumental in determining if these structures are a viable solution to combatting orthopaedic implant infections.
Equilibrative nucleoside transporter 1 (ENT1) transfers nucleosides, such as adenosine, across plasma membranes. We reported previously that mice lacking ENT1 (ENT1-KO) exhibit progressive ectopic calcification of spinal tissues, including the annulus fibrosus (AF) of intervertebral discs (J Bone Miner Res 28:1135–49, 2013, Bone 90:37–49, 2016). Our purpose was twofold: (1) to compare ectopic calcifications in ENT1-KO mice with those in human DISH, and (2) to investigate the molecular pathways underlying pathological calcification in ENT1-KO mice. Studies were performed with age-matched wild-type (WT) and ENT1-KO mice, as well as human cadaveric vertebral columns meeting radiographic criteria for DISH. Mouse and human specimens were scanned using high-resolution, micro-computed tomography (micro-CT). As well, some samples were decalcified and processed for histological assessment. Calcified lesions in selected specimens were examined using energy dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD). To investigate molecular changes associated with ectopic calcification, we isolated AF tissue from thoracic intervertebral discs of WT and ENT1-KO mice. Tissues were then subjected to transcriptomic and proteomic analyses. Micro-CT of ENT1-KO mice revealed ectopic calcification of spinal tissues, first appearing in the cervical-thoracic region and extending caudally with advancing age. Histological examination of calcified lesions in mice revealed accumulations of amorphous, eosinophilic, acellular material in paraspinal ligaments and entheses, intervertebral discs, mandibular symphysis, and sternocostal articulations. There was no evidence of inflammation associated with these lesions. EDX of calcified lesions revealed a high content of calcium and phosphorus in a molar ratio of ∼1.6, with hydroxyapatite detected by micro-XRD. Ten human cadaveric spines (three females and seven males, mean age 81 years) that met radiographic criteria for DISH were analysed in detail by micro-CT. Remarkable heterogeneity in the density and morphology of ectopic calcifications was observed. Analyses of calcifications by EDX and XRD again yielded a calcium/phosphorus ratio of ∼1.6 and a crystalline diffraction pattern matching hydroxyapatite. Histological examination of human lesions revealed regions of mature ossification and other areas of irregular amorphous calcification that resembled lesions in ENT1-KO mice. Microarray analysis of AF tissue from WT and ENT1-KO mice showed extensive dysregulation of transcription in affected tissues. Cell cycle-associated transcripts were the most affected, including the E2f family of transcription factors and proliferating cell nuclear antigen. In addition, expression of genes involved in the regulation of mineralization and bone development were dysregulated. Proteomic analyses confirmed transcriptomic changes and revealed alterations in known modulators of biomineralization such as matrix Gla-protein. Many of the characteristics of ectopic calcification in ENT1-KO mice resemble those of DISH in humans. Human lesions were found to be heterogeneous with regions of pathological ossification and amorphous calcification, the latter resembling lesions in the mouse model. Our studies of the molecular events associated with ectopic calcification in ENT1-KO mice may provide insights into the pathogenesis of DISH in humans. ENT1-KO mice may also be useful for evaluating therapeutics for the prevention of ectopic calcification in DISH and related disorders.
Infections affect 1–3% of Total Knee Arthroplasty (TKA) patients with severe ramifications to mobility. Unfortunately, reinfection rates are high (∼15%) suggesting improved diagnostics are required. A common strategy to treat TKA infection in North America is the two-stage revision procedure involving the installation of a temporary spacer in the joint while the infection is treated for 6–12 weeks before permanent revision. Subdermal temperature increases during infection by 1–4°C providing a potential indicator for when the infection has been cleared. We propose an implantable temperature sensor integrated into a tibial spacer for telemetric use. We hypothesized that suitable sensing performance for infection monitoring regarding precision and relative accuracy can be attained using a low power, compact, analog sensor with <0.1ºC resolution. An experimental sensor was selected for our implanted application due to its extremely low (9 μA) current draw and compact chip package. Based upon dynamic range it was determined that the analog/digital converter must be a minimum of 11 bits to deliver suitable (<0.1ºC) resolution. A 12-bit ADC equipped microcontroller was selected. The MCP9808 (Microchip Technology, Chandler, AZ, USA) delivers manufacturer characterized thermal data in decimal strings through serial communication to the same microcontroller. The rated accuracy of the MCP9808 sensors in the required temperature range is max/typ +/− 0.5/0.25ºC with a precision of +/− 0.05ºC delivered at a resolution of 0.0625ºC. Within a thermally insulated chamber with a resistive heating element, the following experiment was conducted: Using empirical plant modelling tools, simulation and implementation an effective PI control scheme was implemented to create a highly precise temperature chamber. With MCP9808 as reference, the temperature in the thermal chamber was driven to 20 different temperatures between 35 and 40ºC for 10 minutes each and sampled at 5 Hz. This trial was repeated three times over three days. Transient data was discarded so as only to evaluate the steady state characteristics, wavelet denoising was applied, and a regression between the reference MCP9808 temperature response vs the experimental sensor intended for implantation was tabulated in Matlab.Introduction
Materials & Methods