The average age at operation of the survivors was 57.6 years. No significant radiological subsidence between the cement and bone was found. Mean subsidence between the stem and the cement was 2.15mm, most occurring in the first five years and in all but one being less than four. The maximum was 18mm (grade D cementing). Cementing grades were B in 65%, C in 27%, D in 8%. Resorption of the neck (13%) was associated with excessive socket wear or cement left over the cut surface of the neck (the ‘pseudocollar’). Visible cement fractures were found in 14%, none associated with focal lysis, which was seen in 11%.
Two hundred and seventeen consecutive patients (238 hips) underwent total hip arthroplasty using the St Michael’s stem and a non-porous screw ring cup. Patients were followed prospectively clinically using the St Michael’s hip score and radiographically. At an average of 11.9 years (10-13.5 years), 55 patients (59 hips) had died, 23 patients (23 hips) were lost to follow-up. The St Michael’s hip score improved from 13.4 pre-operatively to 21.7 (out of a possible 25) at the latest follow-up. Thirty-seven (24%) of the acetabular components have been revised for aseptic loosening and an additional seven components are radiographically loose. No femoral components have been revised. Using Engh’s criteria one femoral component is definitely loose and two femoral components have stable fibrous ingrowth. Significant stress shielding was noticed in 23 hips (17%) without clinical consequences. Minor osteolysis was seen in 13 hips most commonly around the proximal femur and has not caused symptoms. The St Michael’s stem with its large pore size madreporic surface has comparable results to other porous coated stems with smaller pore size. The St Michael’s stem provided reliable ingrowth and fixation with an acceptable degree of stress shielding. The non-porous screw ring cup had a high failure rate.