Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 74 - 74
1 Dec 2018
Meda M Penfold G Felstead AJ Sturridge S Hill P
Full Access

Aim

We report on the performance of a simple algorithm using a combination of synovial fluid White blood cell count(WBC), C-reactive protein(CRP) and α-Defensin(AD) tests to aid in the diagnosis of prosthetic joint infections.

Methods

Sixty-six synovial fluid samples were collected prospectively in patients with suspected PJI (hip and knee). All samples were tested by: WBC counts (read manually) and CRP test (Alere-Afinion™ validated in-house); and on 37 of these with AD test.

Synovial fluid samples were collected in 5 ml ethylenediaminetetraacetic acid (EDTA) tubes. Samples that were very viscous were pre-processed by the addition of 100µl of hyaluronidase solution. Grossly blood stained and clotted samples were excluded.

A clinical diagnosis of infection was based IDSA definitions1. Cut offs of >3000 × 106 cells/L for total synovial WBC count and >12mg/L for CRP were used to define infection2,3.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 75 - 75
1 Sep 2012
Khakha R Gibbs J Hull J Perry A Chissell H Hill P
Full Access

Introduction

It is now widely accepted that acute knee dislocations should be managed operatively. Most published studies are from outside the UK and from major trauma or specialist centres. The aim of the study is to report the functional outcomes of all patients presenting with an acute knee dislocation at our institution all of whom were surgically managed. The results were then compared to other published series. The hypothesis being that there would be no significant difference in the functional outcome scores between the groups.

Methods

All patients presenting with an acute knee dislocation over the last 15 years were included in the study. The patients were followed up using functional assessment scores: Knee outcome score (ADL), Knee outcome score (sports), Tegner Lysholm Scores and overall Patient Satisfaction. The patients were classified according to the Schecnk classification of knee dislocations.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 153 - 153
1 Jun 2012
Parikh A Hill P Pawar V Morrison M
Full Access

Introduction

Large diameter femoral heads offer increased range of motion and reduced risk of dislocation. However, their use in total hip arthroplasty has historically been limited by their correlation with increased polyethylene wear. The improved wear resistance of highly crosslinked UHWMPE has led a number of clinicians to transition from implanting traditionally popular sizes (28mm and 32 mm) to implanting 36 mm heads. Desire to further increase stability and range of motion has spurred interest in even larger sizes (> 36 mm). While the long-term clinical ramifications are unknown, in-vivo measurements of highly crosslinked UHMWPE liners indicate increases in head diameter are associated with increased volumetric wear [1]. The goal of this study was to determine if this increase in wear could be negated by using femoral heads with a ceramic surface, such as oxidized Zr-2.5Nb (OxZr), rather than CoCrMo (CoCr). Specifically, wear of 10 Mrad crosslinked UHMWPE (XLPE) against 36 mm CoCr and 44 mm OxZr heads was compared.

Materials and Methods

Ram-extruded GUR 1050 UHMWPE was crosslinked by gamma irradiation to 10 Mrad, remelted, and machined into acetabular liners. Liners were sterilized using vaporized hydrogen peroxide and tested against either 36 mm CoCr or 44 mm OxZr (OXINIUM(tm)) heads (n=3). All implants were manufactured by Smith & Nephew (Memphis, TN).

Testing was conducted on a hip simulator (AMTI, Watertown, MA) as previously described [2]. The 4000N peak load (4 time body weight for a 102 kg/225 lb patient) and 1.15 Hz frequency used are based upon data obtained from an instrumented implant during fast walking/jogging and have previously been shown to generate measurable XLPE wear [2,3]. Lubricant was a serum (Alpha Calf Fraction, HyClone Laboratories, Logan, UT) solution that was replaced once per week [2]. Liners were weighed at least once every million cycles (Mcycle) over the duration of testing (∼ 5 Mcycle). Loaded soak controls were used to correct for fluid absorption. Single factor ANOVA was used to compare groups (a = 0.05).