Unicompartmental knee arthroplasty (UKA) currently experiences increased popularity. It is usually assumed that UKA shows kinematic features closer to the natural knee than total knee arthroplasty (TKA). Especially in younger patients more natural knee function and faster recovery have helped to increase the popularity of UKA. Another leading reason for the popularity of UKA is the ability to preserve the remaining healthy tissues in the knee, which is not always possible in TKA. Many biomechanical questions remain, however, with respect to this type of replacement. 25% of knees with medial compartment osteoarthritis also have a deficient anterior cruciate ligament [1]. In current clinical practice, medial UKA would be contraindicated in these patients. Our hypothesis is that kinematics after UKA in combination with ACL reconstruction should allow to restore joint function close to the native knee joint. This is clinically relevant, because functional benefits for medial UKA should especially be attractive to the young and active patient. Six fresh frozen full leg cadaver specimens were prepared to be mounted in a kinematic rig (Figure 1) with six degrees of freedom for the knee joint. Three motion patterns were applied: passive flexion-extension, open chain extension, and squatting. These motion patterns were performed in four situations for each specimen: with the native knee; after implantation of a medial UKA (Figure 2); next after cutting the ACL and finally after reconstruction of the ACL. During the loaded motions, quadriceps and hamstrings muscle forces were applied. Infrared cameras continuously recorded the trajectories of marker frames rigidly attached to femur, tibia and patella. Prior computer tomography allowed identification of coordinate frames of the bones and calculations of anatomical rotations and translations. Strains in the collateral ligaments were calculated from insertion site distances.Introduction
Materials and Methods
Despite high success rates following total knee arthroplasty (TKA), knee kinematics are altered following TKA. Additionally, many patients report that their reconstructed knee does not feel ‘normal’ [1], potentially due to the absence of the anterior cruciate ligament (ACL), an important knee stabilizer and proprioceptive mechanism. ACL-retaining implants have been introduced with the aim of replicating native knee kinematics, however, there has yet to be a detailed comparison between knee kinematics in the native knee and one reconstructed with an ACL-retaining implant. Six fresh-frozen right legs (77±10 yr, 5 male) were mounted in a kinematic rig and subjected to squatting (40°-105°) motions. The vertical positon of the hip was manipulated with a linear actuator to induce knee flexion while the quadriceps were loaded with an actuator to maintain a vertical load of 90 N at the ankle [2]. Medial/lateral hamstring forces were applied with 50 N load springs. During testing, an infrared camera system recorded the trajectories of spherical markers rigidly attached to the femur and tibia. Two trials were performed per specimen. Following testing on the native knee, specimens were implanted with an ACL-retaining TKA (Vanguard XP, Zimmer Biomet) and all trials were repeated. Three inlay thicknesses were tested to simulate optimal balancing as well as over- (1 mm thicker) and understuffing (1 mm thinner) relative to the optimal thickness. Pre-operative computed tomography scans allowed identification of bony landmarks and marker orientation, which were used define anatomically relevant coordinate systems. The recorded marker trajectories were transformed to anatomical translations/rotations and resampled at increments of 1° of knee flexion. Translations of the medial and lateral femoral condyle centers were scaled to maximum anterior-posterior (AP) width of the medial and lateral tibial plateau, respectively. For all kinematics, statistical analysis between knee conditions was conducted using repeated measures ANOVA in increments of 10° knee flexion. Internal rotation of the tibia was significantly lower (p<0.05) for the three reconstructed conditions relative to the native knee at flexion angles of 60° and below. No significant differences in tibial rotation were observed between the balanced, overstuffed, or understuffed conditions. The varus orientation was not significantly influenced by implantation, regardless of inlay thickness, for all flexion angles. At 40° flexion, the AP position of the femoral medial condyle was significantly more anterior for the native knee relative to the balanced and understuffed conditions. This finding was not significant for the other flexion angles. No significant differences were found for the lateral condyle center AP position at any flexion angle. Preservation of the cruciate ligaments during total knee arthroplasty may allow better physiologic representation of knee kinematics. The implants tested in this study were able to replicate kinematics of the native knee, except for tibial rotation and AP position of the medial femoral condyle in early knee flexion. Interestingly, the impact of inlay thickness was generally small, suggesting some tolerance in the choice of inlay thickness.
Oxidized zirconium (OxZr) is used as a ceramic surface for femoral components in total knee arthroplasty (TKA). The aim of this study was to investigate its performance by examining retrieved femoral components and their corresponding PE inserts in matched comparison with conventional chrome/cobalt/molybdenum alloy (CrCoMo). 11 retrieved posterior stabilized (PS) TKA with an OxZr femoral component were included. From a cohort of 56 retrieved TKA with CrCoMo femoral components, pairs were matched according to duration of implantation, patient age, reason for revision, and BMI. The retrieved tibial polyethylene (PE) inserts were analyzed for wear using the Hood classification. Femoral components were optically viewed at 8–32x magnification and screened for scratching, pitting, delamination, and striation. Profilometry was performed to measure surface roughness of the OxZr components using a non-contact white light profiler.Introduction
Methods
After resection of the PCL differences in contact pressures and contact area between DD and PS failed to reach statistical significance although there was an obvious tendency towards lower pressures with the PS-design.
There is a high risk of venous thromboembolism when patients are immobilised following trauma. The combination of low-molecular-weight heparin (LMWH) with graduated compression stockings is frequently used in orthopaedic surgery to try and prevent this, but a relatively high incidence of thromboembolic events remains. Mechanical devices which perform continuous passive motion imitate contractions and increase the volume and velocity of venous flow. In this study 227 trauma patients were randomised to receive either treatment with the Arthroflow device and LMWH or only with the latter. The Arthroflow device passively extends and plantarflexes the feet. Patients were assessed initially by venous-occlusion plethysmography, compression ultrasonography and continuous wave Doppler, which were repeated weekly without knowledge of the category of randomisation. Those who showed evidence of deep-vein thrombosis underwent venography for confirmation. The incidence of deep-vein thrombosis was 25% in the LMWH group compared with 3.6% in those who had additional treatment with the Arthroflow device (p <
0.001). There were no substantial complications or problems of non-compliance with the Arthroflow device. Logistic regression analysis of the risk factors of deep-vein thrombosis showed high odds ratios for operation (4.1), immobilisation (4.3), older than 40 years of age (2.8) and obesity (2.2).