header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 12 - 12
17 Jun 2024
Shah K Battle J Hepple S Harries B Winson I Robinson P
Full Access

Background

Open subtalar arthrodesis has been associated with a moderate rate of non-union, as high 16.3%, and high rates of infection and nerve injury. Performing this operation arthroscopically serves to limit the disruption to the soft tissue envelope, improve union rates and reduce infection. Our study describes our outcomes and experience of this operation.

Method

Retrospective review of all patients who underwent an arthroscopic subtalar arthrodesis between 2023 and 2008. We excluded patients undergoing concurrent adjacent joint arthrodesis. The primary aim was to report on rates of union. Secondary outcomes included reporting on conversion to open procedure, duration of surgery, infection, and iatrogenic injury to surrounding structures.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 2 - 2
4 Jun 2024
Townshend D Bing A Clough T Sharpe I Blundell C Davenport J Davies H Davis J Dhar S Goldberg A Karski M Hepple S Kakwani R McKinley J Murty A Ragland M Shalaby H Smith R Taylor H
Full Access

Introduction

This is a multi-centre, prospective, observational study of 503 INFINITY fixed bearing total ankle arthroplasties. We report the minimum two-year results of this prosthesis which was introduced to the UK Market in 2014 and is now the most used ankle arthroplasty in the National Joint Registry of England and Wales.

Methods

Patients were recruited from 11 centres in the United Kingdom between June 2016 and November 2019. Demographic, radiographic, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Foot Ankle Questionnaire and Euroquol 5D-5L) were collected preoperatively, at 6 months, 1 year and 2 years and 5 years. The average age was 67.8 (range 23.9 to 88.5) and average BMI 29.3 (18.9 to 48.0). The COFAS grading system was used to stratify deformity. There were 261 (51.9%) COFAS Type 1, 122 (24.2%) COFAS Type 2, 31 (6.2%) COFAS 3 and 89 (17.7%) COFAS type 4. 38 patients (7.6%) presented with inflammatory arthritis. 99 (19.7%) implantations utilised patient specific instrumentation. Complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts and/or subsidence.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 17 - 17
8 May 2024
Senthi S Miller D Hepple S Harries W Winson I
Full Access

Tendoscopy in the treatment of peroneal tendon disorders is becoming an increasingly safe, reliable, and reproducible technique. Peroneal tendoscopy can be used as both an isolated procedure and as an adjacent procedure with other surgical techniques. The aim of our study was to review all peroneal tendoscopy that was undertaken at the AOC, by the senior authors (IGW, SH), and to determine the safety and efficacy of this surgical technique.

Methods

From 2000 to 2017 a manual and electronic database search was undertaken of all procedures by the senior authors. Peroneal tendoscopy cases were identified and then prospectively analysed.

Results

51 patients (23 male, 28 female) were identified from 2004–2017 using a manual and electronic database search. The mean age at time of surgery was 41.5 years (range 16–83) with a mean follow-up time post operatively of 11.8 months (range 9–64 months). The main indications for surgery were lateral and/or postero-lateral ankle pain and lateral ankle swelling. The majority of cases showed unstable peroneal tendon tears that were debrided safely using tendoscopy. Of the 51 patients, 23 required an adjacent foot and ankle operation at the same time, 5 open and 17 arthroscopic (12 ankle, 5 subtalar). Open procedures included 2 first ray osteotomies, 2 open debridements of accessory tissue, one PL to PB transfer. One patient also had an endoscopic FHL transfer. Complication rates to date have been low: 2 superficial wound infections (4%) and one repeat tendoscopy for ongoing pain. A small proportion of patients with ongoing pain were treated with USS guided steroid injections with good results.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_21 | Pages 22 - 22
1 Dec 2017
Robinson P Senthi S Nall A Hepple S Harries W Winson I
Full Access

Introduction

Flexor Hallucis Longus (FHL) tendon transfer is a well-recognised salvage operation for irreparable tendon Achilles (TA) ruptures and intractable Achilles tenonopathy. Several case series describes the technique and results of arthroscopic FHL tendon transfers. We present a comparative case series of open and arthroscopic FHL tendon transfers from Southmead Hospital, Bristol, UK.

Methods

For the arthroscopic FHL transfers in most cases the patients were positioned semi prone with a tourniquet. A 2 or 3 posterior portal technique was used and the tendon was secured using an RCI screw. The rehabilitation was similar in both groups with 2 weeks in an equinus backslab followed by gradual dorsiflexion in a boot over the following 6 weeks. Anticoagulation with oral aspirin for 6 weeks was used. A retrospective case note review was performed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_19 | Pages 19 - 19
1 Nov 2016
Sinclair V O'Leary E Pentlow A Hepple S Harries B Winson I
Full Access

Introduction

Arthroscopic ankle fusion is an effective treatment for end stage ankle arthritis. It reliably improves pain but at the expense of ankle motion. Development of adjacent degenerative joint disease in the foot is thought to be a consequence of ankle fusion due to altered biomechanics. However, it has been reported to be present on pre-operative radiographs in many patients. There is very little evidence reporting the long-term outcomes of patients undergoing arthroscopic ankle fusion and particularly those requiring secondary procedures for adjacent joint disease.

Material and methods

We reviewed the operative records of 149 patients who had undergone arthroscopic ankle fusion under the care of two consultant foot and ankle surgeons between 2002 and 2006. We contacted patients by telephone to determine whether they had required further investigation or surgery on the same foot after their index procedure. Secondary outcome measures included a Manchester Oxford Foot Questionnaire (MOQFQ) score and a patient satisfaction score.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_14 | Pages 15 - 15
1 Dec 2015
Walter R Harries W Hepple S Winson I
Full Access

The ZenithTM total ankle replacement (Corin, Cirencester) is a mobile-bearing implant based on the Buechal Pappas design. Key features are the simple fully-jigged instrumentation aiming to improve accuracy and reproducibility of implant positioning, cementless calcium phosphate coated surfaces for improved early osseointegration, and titanium nitride-coated bearing surfaces to resist wear. We present early to mid-term survival data for 155 total ankle replacements implanted by three surgeons in our institute.

Case records of all patients undergoing ZenithTM Total Ankle Replacement by three senior surgeons, including a member of the design team, between 2007 and 2014 were examined. Patients were examined clinically and radiographically annually after the early postoperative period. The primary outcome measure was implant survival. Secondary outcome measures included complication rates, parameters of radiographic alignment, and radiographic evidence of cysts and loosening.

One hundred and fifty-five cases were performed for a mixture of primary pathologies, predominantly primary or posttraumatic arthrosis. Mean follow-up was 50 months. Implant survival was 99.0% at 3 years (n=103), 94.0% at 5 years (n=50), and 93.8% at 7 years (n=16). One patient was revised to arthrodesis for aseptic loosening, one arthrodesis was performed for periprosthetic infection with loosening, and one below-knee amputation was performed for chronic pain. Three cases underwent further surgery to address cysts, and 7 malleolar fractures were reported. Medial gutter pain was experienced by 9% of patients.

Overall, our data show excellent early and mid-term survivorship for the ZenithTM Total Ankle Replacement. Simple fully-jigged instrumentation allows accurate and reproducible implant alignment.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_2 | Pages 4 - 4
1 Jan 2014
Kakwani R Higgs A Hepple S Harries W Winson I
Full Access

Aim:

Ankle sprains are one of the most common sports injuries. Around 10–20 % of the acute ankle sprains may lead to the sequelae of chronic ankle instability. Around 15–35% of the patients have residual pain following successful lateral ligament reconstruction. One of the reasons suggested for the persistent symptoms following lateral ligament reconstruction has been the presence of intra-articular pathology.

Methods and materials:

We performed ankle arthroscopy on all patients undergoing the modified Brostrom repair and compared patients with associated intra-articular pathology to those without any intra-articular pathology.