We present a series of 23 total ankle replacements revised for balloon osteolysis and aseptic loosening with a hind-foot fusion nail without the use of bone graft. This is the largest series of total ankle replacements revised to a hindfoot fusion with a nail presented in the literature. Initial assessment involved investigations to rule out infection and a CT scan of the ankle to assess the size of cysts. Patients underwent surgery in a single stage procedure. The surgery involved excision of the fibula and preparation of the sub-talar joint through a lateral incision; removal of the implant and preparation of the talar and tibial surface with flat cuts through an anterior incision and safe excision of the medial malleolus aided by a medial incision. The prepared surfaces were then compressed and fixed using a Biomet Phoenix Nail. Patients were then followed up to assess for clinical and radiographic union. This study involved 18 male and 4 female patients with an average age of 67. All patients had AES ankle replacements (Biomet) in-situ, undergoing revision surgery for aseptic loosening with balloon osteolysis. At a mean follow up of 13.9 months, 96% (22/23) of ankles achieved osseous union across the tibio-talar joint with 1 patient achieving a partial union. 91% (21/23) of patients achieved union across the subtalar joint with 2 patients identified as having a non-union. 1 patient with a subtalar non-union suffered a broken nail and required revision surgery. The only other identifiable complication was a single patient sustained a stress fracture at the proximal tip of the nail, which was treated conservatively. We believe this method is a reliable and reproducible method of achieving osseous union following a failed total ankle replacement without using graft. Although patients may have a leg length discrepancy, none have requested leg lengthening.
We present the early results of 220 Rebalance Total Ankle Replacements performed in 6 centres in 4 different countries. The Rebalance Total Ankle Replacement is a new 3 component uncemented mobile bearing prosthesis with a surface coating of ‘bonemaster’ and an ‘e’ poly bearing. The prosthesis was released in a limited way in May 2011. Since then 220 replacements have been implanted in 218 patients in 6 centres in 4 different countries (UK, Sweden, Canada, Czech Republic). All the x-rays and case notes were reviewed.63 prostheses have a minimum follow up of 2 years. Outcome measures included revision of the prosthesis, and the incidence of progressive and non-progesssive radiolucent lines around the prosthesis.Introduction:
Methods:
Stress fractures in the foot are common; the common practice is to look for any factor in the history or for any foot deformity that could cause the fracture. Once found, it is common to treat the fractures without further investigations. The aim of this study is to assess if we are missing any underlying metabolic disorder associated with such injury. We studied 34 sequential cases referred for chronic foot pain. Stress fractures were confirmed either by classic x-ray's features or MRI. Clinical examination and further tests were performed for Vitamin D levels, Thyroid function, PTH, DEXA scan, Biochemical and bone profile. All stress fractures were treated conservatively.Introduction
Materials and methods
Numerous procedures have been reported for the We wish to report a patient who had lengthening SCARF osteotomy for the metatarsalgia following previous She had a lengthening SCARF This case highlights that arthritis of the 1st MTPJ can occur in the absence of an AVN of the metatarsal head and patients need to be warned of this potential complaining when having the lengthening SCARF
Numerous techniques are used for the fusion of failed TAR. We wish to report our results of the revision of failed TAR to fusion. Between July 2005 and February 2011 the senior author had performed 20 The mean follow-up was 15 months. All 3 tibiotalar arthrodeses with screws alone fused successfully. Of the 13 patients where the fusion was augmented with an Ilizarov frame, 4 were done for septic loosening. There were 2 non unions of which one was stable without pain and the other required a further revision fusion with a frame and subsequently fused. Of the 9 patients who had a fusion with a frame for osteolysis and or aseptic loosening, there was one non union which was revised to a tibiotalocalacaneal fusion with a hind foot nail. The nail fractured at the level of the posterior oblique screw hole. The patient subsequently developed a relatively pain free non-union of the tibiotalar joint and not required further surgical intervention. The remaining 8 ankles fused at a mean of 5 months. The average time of frame removal was 17 weeks. There was four pin-site infection all of which settled with oral antibiotics. 5 patients had tibiotalocalacaneal fusion with a hind foot nail. The indication for the hind foot nail was significant osteolysis and loss of talar bone stock. The average shortening as a result of the fusion for the failed TAR was 1.5cms. Our results were comparable to the previous reports of arthrodesis for failed total ankle replacement. We recommend the use of tibiotalocalcaneal fusion with a hind foot nail in the presence of severe osteolysis or accompanying subtalar arthritis. In the presence of good bone stock an ankle fusion supplemented with a circular frame gives a good predictable outcome.