Cementless prosthesis is one of the major bone-implant interface fixation methods in total joint replacement. Grit blasted surface, hydroxyapatite coated surface and plasma sprayed metallic porous coating have been popularly used. The latter has demonstrated higher bone implant mechanical stability in previous laboratory study in early and middle stages. However, question remains what the mechanism is to make it performing better and how to improve them further. This study is designed to examine the mode of failure in bone-implant interface in a sheep model. Plasma sprayed porous coated (TiPL); hydroxyapatite (HA) coated and and grit blasted (TiGB) titanium implants were examined in the study. Each type has 36 specimens. Implants were inserted into cortical bones in a press-fit fashion in a total of 22 sheep bilateral hind limbs. Specimens were retrieved at 4 weeks and 12 weeks. Push- out testing was performed to just reach ultimate failure. Failed bone-implant interface were investigated by histology and BSEM. The percentage of failure at bone-coating interface, bone itself fracture, coating itself failure, and coating-substrate dissociation were measured by BSEM.Aim
Method
This study was performed to compare the mechanism of bone-implant integration and mechanical stability among three popularly used cementless implant surfaces. Plasma sprayed porous surface (TiPL), grit-blasted rough surface (TiGB), and hydroxyapatite coated implant surface (HA) were tested in a sheep model at 4 and 12 weeks. The integration patterns were investigated using histology, histomorphometry, and mechanical strength by push-out test. All three groups demonstrated early bone ongrowth on their surfaces, with much of the ongrowth resembling contact osteogenesis. TiPL group showed bone anchorage into porous coating with new bone ingrowth into the pores. HA group revealed small cracks at its coating at 12 weeks time point. Plasma sprayed porous surface also demonstrated its superior mechanical stability maybe reinforced by its bone anchorage, whearas, HA surface exhibited higher osteoconductivity with highest ongrowth rate.
Animal studies examining tendon-bone healing have demonstrated that the overall structure, composition, and organization of direct type entheses are not regenerated following repair. We examined the effect of Low-Intensity Pulsed Ultrasound (LIPUS) on tendon-bone healing. LIPUS may accelerate and augment the tendon-bone healing process through alteration of critical molecular expressions. Eight skeletally mature wethers, randomly allocated to either control group (n=4) or LIPUS group (n=4), underwent rotator cuff surgery following injury to the infraspinatus tendon. All animals were sacrificed 28 days post surgery to allow examination of early effects of LIPUS. Humeral head – infraspinatus tendon constructs were harvested and processed for histology and immunohistochemical staining for BMP2, Smad4, VEGF and RUNX2. All the growth factors were semiquantitative evaluated. T-tests were used to examine differences which were considered significant at p < 0.05. Levene's Test (p < 0.05) was used to confirm variance homogeneity of the populations. The surgery and LIPUS treatment were well tolerated by all animals. Placement of LIPUS sensor did not unsettle the animals. Histologic appearance at the tendon-bone interface in LIPUS treated group demonstrated general improvement in appearance compared to controls. Generally a thicker region of newly formed woven bone, morphologically resembling trabecular bone, was noted at the tendon-bone interface in the LIPUS-treated group compared to the controls. Structurally, treatment group also showed evidence of a mature interface between tendon and bone as indicated by alignment of collagen fibres as visualized under polarized light. Immunohistochemistry revealed an increase in the protein expression patterns of VEGF (p = 0.038), RUNX2 (p = 0.02) and Smad4 (p = 0.05) in the treatment group. There was no statistical difference found in the expression patterns of BMP2. VEGF was positively stained within osteoblasts in newly formed bone, endothelial cells and some fibroblasts at the interface and focally within fibroblasts around the newly formed vessels. Expression patterns of RUNX2 were similar to that of BMP-2; the staining was noted in active fibroblasts found at the interface as well as in osteoblast-like cells and osteoprogenitor cells. Immunostaining of Smad4 was present in all cell types at the healing interface. The results of this study indicate that LIPUS may aid in tendon to bone healing process in patients who have undergone rotator cuff repair. This treatment may also be beneficial following other types of reconstructive surgeries involving the tendon-bone interface.
The transosseous equivalent/Suture Bridge or TOE/SB repair has received much attention in recent years as more shoulder surgeons transition to all arthroscopic rotator cuff repairs. The purpose of this study was to compare the biomechanical behaviour of several variants of the Suture Bridge repair performed by the authors. Four different Suture Bridge constructs were performed six times on 24 sheep infraspinatus tendon humerus constructs. The first group was a standard Suture Bridge with two medial mattress stitches with knots (KSSB4). The second group had four medial mattress stitches with knots and was called KDSB8. The third group had two medial mattress stitches without knots and was called USBFT4. These first three repairs used two medial 5.5 mm Bio-Corkscrew FT Anchors and two lateral 3.5 mm PushLock Anchors (Arthrex). The fourth repair had two medial mattress stitches without knots and used all Pushlocks and was called USBP4. The repairs were then analysed for failure force, cyclic creep and stiffnessafter. Cycling was performed from 10 to 100 N at 1 Hz for 500 cycles. Following cyclic testing a single cycle pull to failure at 33 mm/sec was performed. The constructs were also observed for failure mechanism and gap formation using digital video recording. The KDSB8 repair with a mean failure force of 456.9N was significantly stronger than the USBP4 repair at 299.7N (P=0.023), the KSSB4 repair at 295.4N (P=0.019) and lastly the USBFT4 repair at 284.0N (P=0.011). There was no statistical difference between the measured failure force for the two mattress stitch KSSB4 repair with knots and the knotless two mattress stitch repairs USBFT4 and USBP4. There was not a statistical difference between any of the repairs for measured stiffness and cyclic creep. However, the KDSB8 repair showed no discernable gap formation or movement at the footprint during cyclic testing. The KSSB4, USBFT4 and USBP4 repairs demonstrated bursal sided gap formation in the range of 1 to 3 mm. Based on the results of this study the transosseous equivalent/Suture Bridge repair with four stitches tied in the medial row and maximal lateral suture strand utilization (KDSB8 TOE/SB) is the strongest. The KDSB8 also appeared to show less bursal sided gap formation and greater footprint stability than the other Suture Bridge constructs tested.
NICE published the guidelines ‘Selection of prostheses for primary hip replacement’ in 2000. Essentially these guidelines made two recommendations: firstly to use prostheses which had attained the ‘10 year benchmark’ of a revision rate of 10% or less at 10 years, or had a minimum of three years revision rate experience that was on target to reach this benchmark; and secondly to use cemented hip prostheses to the exclusion of uncemented and hybrid prostheses. The information from the Trent Regional Arthroplasty Study (TRAS) has been used to retrospectively examine the types of hip prostheses used from 1990 – 2005, and assess the impact that the NICE guidelines have had on orthopaedic practice. This study revealed that the percentage of prostheses used which attained the ‘ten year benchmark’ has increased since the guidelines were published. In 2001, of the ten cups, which constituted 80% of the acetabular components used, only three attained this NICE benchmark, but by 2005 this number had risen to eight. Similarly in 2001, of the eight stems, which constituted almost 80% of the femoral components used, only five attained this NICE benchmark. In 2005 seven out of these eight stems had attained the minimum standard. However contrary to the recommendation made by NICE in 2000, to use cemented prostheses, the results indicate the use of uncemented prostheses has trebled (from 6.7% to 19.2%, n= 137 and 632 respectively), and the use of hybrid prostheses has more than doubled (from 8.8% to 22% of all prostheses, n= 181 and 722 respectively) since the guidelines were published. Therefore the recommendations made by NICE are not being followed, which calls the value of NICE guidelines into question.
The literature is filled with reports of various studies identifying perioperative factors that adversely affect survival. The aim of this study was to identify perioperative factors associated with an increased risk of death at 5 years. All patients admitted to our unit in 2002 with a proximal femoral fracture were included. Demographic details, physiological parameters and biochemical parameters on admission were documented. Survival data at five years was available for all patients and was used to perform survival analyses. 633 patients with a proximal femoral fracture were admitted to our unit between January 2002 to December 2002. Data for all patients was available for analysis. There were 118 men and 515 women, M:F =1:1.4. Average age of the patients was 81.2±9.4 years (range 45–105 years). Univariate analysis showed that patient age, mental test score, number of days delayed to surgery, number of comorbidities, ASA grade, if the patient lived in an institution, had a previous stroke, suffered from congestive cardiac failure or valvular heart disease, heart rate, serum haemoglobin, serum urea and whether the patient developed a post operative complication were all significant factors that affected survival. Multivariate analysis showed that mental test score (Exp B=0.939 95%CI=0.901–0.978 p= 0.002), age (Exp B = 1.031 95%CI= 1.004–1.058 p= 0.025) and ASA grade (Exp B = 1.458 95%CI= 1.039–2.046 p= 0.029) were all independent variables that affected five year survival. Various independent factors affect five year survival in patients with proximal femoral fracture. It is important that these factors are identified firstly, so that patients and relatives can be given information about survival and secondly, so that high risk patient groups can be allocated adequate resources in order that their peri and postoperative care is optimised. This may improve outcome in these subgroups of patients.
It is has been suggested that as a result of the skewed age distribution, the incidence of hip fracture will increase disproportionately among Asians. The epidemiology of hip fracture among the Asian and White populations in Leicestershire the five year survival between the two groups was investigated. All patients in Leicestershire with hip fracture between 2001–2 were studied. Demographic data, type of fracture, and treatment was recorded. Ethnic origin was noted as White, Asian, or other. Survival at 5 years was documented as number of days survived. The results were analysed statistically. On thousand one hundred and thirty-four patients were admitted to our unit with hip fracture, 617 intracapsular fractures and 517 extracapsular fractures. Leicestershire Census data in 2002 showed that 85.7% of the population was white, 11.9% Asian and the remaining 2.4% of other ethnic group. The percentage of Asians >
65 years was 8.8% compared to 18.9% of whites. The number of Asian patients <
65 years with a hip fracture was significantly greater than the number of whites <
65 years (p =0.002, Fishers exact test). Five year survival of Asian patients <
65 years with hip fracture was significantly lower than white counterparts in the same age group (p = 0.002) Over the last decade there has been a 30% increase in the Asian population in Leicestershire (9.3% to 11.9%). The proportion of Asians over 65 years doubled over the last decade from 4.3% to 8.8%. The proportion of Whites over 65 years increased from 16.3% to 18.9%. The 5 year survival of Asians with hip fracture under 65 years old is significantly reduced when compared to Whites. This suggests that Asians under the age of 65 years that sustain hip fracture may have other risk factors that may contribute to their earlier demise.
The aim of this study was to evaluate temporal trends in the prevalence of primary total hip and knee replacements (THR and TKR) throughout the Trent region from 1991 through 2004. The Trent Regional Arthroplasty Study (TRAS) records details of primary THR and TKR prospectively. TRAS data in conjunction with age-gender population data from the National Office of Statistics was used to quantify the rates of primary THR and TKR as a function of age (45–55, 56–65, 66–75, 76–85 and greater than 85 years), gender and diagnosis (osteoarthritis, rheumatoid arthritis and trauma). Poisson regression analysis was used to evaluate the procedural rate over time in primary THR and TKR as a function of age, gender and diagnosis. A total of 26,281 THR and 23,606 TKR were recorded during this period. The overall prevalence for primary THR did not change significantly over time (IRR = 1.0, 95% CI: 0.99 to 1.0, p = 0.875), whereas, the overall prevalence for primary TKR increased significantly by 2.5% during the fourteen year period (IRR = 1.025, 95% CI: 1.021 to 1.028, p <
0.001). Analysis showed that females had an increased incidence rate ratio (IRR) for both primary THR (IRR = 1.29, 95% CI: 1.26 to 1.33, p <
0.001) and TKR (IRR = 1.17, 95% CI: 1.14 to 1.20, p <
0.001). Patients aged 74–85 years had the largest IRR for both primary THR (IRR = 6.7, 95% CI: 6.4 to 7.0, p <
0.001) and TKR (IRR = 15.3, 95% CI: 14.4 to 16.3, p <
0.001). The prevalence of primary TKR increased significantly over time whereas THR increased steadily in the Trent region between 1991 and 2004. These trends have important ramifications to the number of joint replacements expected to be performed in the future.
Seven specimens were used for mechanical analysis. A humeral osteotomy was performed distal to the insertion of pectoralis major, leaving intact the biceps sheath and the muscle belly of long head of biceps. The proximal humerus was attached to a custom-designed jig and the muscle belly of biceps grasped in cryogenic grips. Specimens were loaded on an MTS 858 Bionix mechanical testing machine (MTS Systems, MN) in uniaxial tension at a rate of 1 mm/sec until failure was observed.
Histological examination of the biceps sheath revealed membranous tissue consisting of loose soft tissue with fat and blood vessels. Synovial tissue was also identified. The sheath was seen to loosely attach to the biceps tendon, with a more intimate attachment to the periosteum. The mean force to pull the long head of biceps tendon out of the sheath 102.7 N (range 17.4 N–227.6 N)
In this study we have traced all the patients, who had a primary total knee replacement between 1990 and 1992. We issued a validated, self administered questionnaire to all surviving patients, at a mean of fifteen years post arthroplasty. This questionnaire examines the patient’s level of expectation and satisfaction with their TKR, and also measures their quality of life (using EQ-5D and visual analogue score). Using a similar register, containing information of all revision TKR in the region, we have measured the survivorship of these primary TKR at 10 and 15 years.
Survivorship analysis revealed that 94.7% (+/−0.4%) of implants survive to 10 years, and 92.7% (+/−0.5%) to 15 years. Survivorship was significantly affected by gender of the patient, age at time of primary, and type of prosthesis used. Infection rate at 15 years was 0.9%.
Approximately 10% of primary hip replacements performed each year for osteoarthritis are in patients aged 55 or less. These patients have a longer life expectancy and a higher activity level than an elder cohort, which may translate to higher revision rates. We utilized a regional hip register (Trent and Welsh Arthroplasty Audit Group (TWAAG)) to review current surgical practice in this age group. The TWAAG group comprises 118 surgeons working in 31 different hospitals covering a population of 8 million (14.2% of the population). 1 January 2000 to 31 December 2002, we were notified of 7,678 primary THRs for osteoarthritis. 911 (11.7%) were performed on patients aged 55 or less. Age, gender, grade of lead operating surgeon, type of femoral and acetabular prosthesis implanted, fixation method, femoral head size and bearing surfaces were recorded. There were 434 males, 477 females, with an age range of 16–55. Thirty-five femoral and thirty-three acetabular components were identified. 61.7% of femoral prostheses were cemented. 67.4 % of acetabular prostheses were uncemented. 30% of THRs implanted in the group over the study period were hybrid. 50% of implants had a metal/UHMWPE bearing. Other bearing surfaces comprised ceramic/UHMWPE 28.7%, metal/ metal resurfacing 13.8% and ceramic/ceramic 7.5%. Consultants performed 84.5% of procedures. Femoral prostheses with little or no published data are used and, unless closely monitored, such practices will not be compliant with NICE recommendations. 40% of THRs performed had components implanted that were produced by different manufacturers. At the present time there does not appear to be a clear picture as to what is the ‘gold’ standard for young patients. Continued monitoring of these implants is essential to provide feedback and drive choice.
The Trent Arthroplasty Audit Group has been prospectively collecting data on primary hip and knee arthroplasties since 1990. Details of 61,000 primary and 4,00 revision arthroplasties have been registered. The Royal College of Surgeons of England. Capital Hip Report (July 2001) concluded that a national joint register could have detected failures of an implant at an earlier stage. We examined data on the register to ascertain why we had been unable highlight a problem with this implant. The Trent Arthroplasty Register was unable to detect the poor results with Capital hips at an earlier stage than surgeons. A scientific presentation had raised concern before our register could detect a problem. The hips had been listed for revision but were still on a waiting list. Additionally some of the failed hips were not revised as patients were insufficiently fit for surgery. The stated reason for revision on revision forms was vague and not sufficient to draw conclusions as to the mechanism of failure. Radiological studies have identified a higher radiological failure rate than expected (Charnley &
Elite +) but we have shown that outcome scores (Oxford Scores) were not successful at identifying these failures. Since the implementation of the Data Protection Act (1998) consent must be obtained before details are registered, which may lead to further inaccuracy in the creation of survivorship curves. Joint registers can contain the problem once it is detected but are not a substitute for regular follow-up. Surgical vigilance and a scientific approach is required to ascertain the reason for failure. Revision should not be the only endpoint for registration. Joint registers may be part of the solution but need to be backed up with adequate resources, financial and intellectual, to analyse clinical information, if valid conclusions are to be drawn.
This meta-analysis supports the conclusion that in patients with recurrent traumatic anterior shoulder instability, an open repair has a more favorable outcome with respect to recurrence and return to activity when compared to arthroscopic repair. More evidence from randomized clinical trials is required to either refute or substantiate this conclusion. The purpose of this study was to evaluate the outcomes between arthroscopic and open repair for recurrent traumatic anterior shoulder instability. The search involved clinical studies of all languages in the Medline database up to October 31, 2001. The following key words were used:
anterior shoulder instability; Bankart lesion; traumatic recurrent anterior shoulder instability; and arthroscopic and open Bankart repair. All abstracts were reviewed and articles were included if there was a direct comparison between arthroscopic and open repair for traumatic recurrent anterior shoulder instability. These articles were manually assessed and cross-referenced for additional abstracts. The final group of articles were independently critically appraised and data on recurrent instability and return to activity (RTA) was extracted. Recurrent instability was defined as patient report of one or more subluxations and/or dislocations. RTA was not consistently defined in these articles and was based upon the available information.
584, 161, 59 and 44. From these searches, sixteen articles were determined eligible for the meta-analysis including two foreign and two unpublished manuscripts. Ten studies were included in the final analysis: one RCT, two pseudo-experimental designs, four prospective cohorts, and three retrospective studies. Pooled Mantel-Haenszel Odds Ratio for recurrent instability and RTA were 2.22 Based upon this meta-analysis open repair has a more favorable outcome with respect to recurrence and RTA.
We sought to determine the incidence of complications and re-operation up to one year following primary total knee replacement in a single health region. The Trent Arthroplasty Audit group collects prospective data on all knee replacements performed within this health region (population 5.2 million). All patients are sent a validated, self-administered questionnaire one year after surgery. The questionnaire addresses patient satisfaction and any complications and re-operations following surgery. We analysed the returned questionnaires of 5352 patients [5896 knees] who had their primary knee arthroplasty between 1998 to 2000. Responses were received from 4169 patients [4592 knees] (response rate 80%). Clinical records were also examined to gain further information. 516 patients reported complications in 546 knees. Complication rate of (12%) and 3.5% had a further operation on the joint within one year. Complications were highest following knee replacement for trauma (36%) followed by osteoarthritis (12%) and lowest for rheumatoid arthritis (8%). We have no knowledge of the complexity of the surgery but 60% of the complications occurred in patients operated on by a Consultant, 29% by a Specialist Registrar and 10% by an Associate Specialist &
Staff Grade. On the whole Consultants performing fewer than 10 joint replacements per year registered a higher complication rate (21%) as compared to Consultants performing more than 25 joints per year (12%), but they performed 18% of the arthroplasties. The incidence of complications, as stated by the patient was as follows: Pain 7%, Stiffness 2%, Superficial infection 1%, Swelling 0.7%, Deep infection 0.7%, DVT 0.4%. 1.2% (infection 0.4%: Instability 0.7%: Patellar resurfacing 0.2%), Manipulation (1.3%), Arthroscopy (0.7%), ORlF of Peri-prosthetic fracture (0.06%). 12 % of the patients who had a primary knee replacement in Trent region between 1998 and 2000 considered that they had a complication. Complications rates appear to be higher for surgeons performing less than 10 joint replacements per year. Only 43% of Consultants performed more than 10 knee arthroplasties themselves in any one of these three years. The deep infection rate was 0.4% and one-year post surgery the revision rate, for all causes was 1.2% and the manipulation rate was 1.3%.
The Trent Arthroplasty Audit Group has been prospectively collecting data on primary knee arthroplasty since 1990 and revision procedures since 1992. Details of 27 000 primary and 1300 revision knee arthroplasties have been registered. In 2001 hospitals in Wales joined the group, increasing the catchment population to 8 million (14% of the UK population). The register has enabled evaluation of changes in the demography and surgical practice of knee arthroplasty in the Trent region over the past 13 years. Over this period there has been a steady increase in the number of arthroplasties registered, from 1330 cases in 1990 to 2855 in 2002. Whilst there has been a slight increase in the proportion of men undergoing surgery, the age distribution remains consistent (mean age 69 years). PFC/Sigma is currently the most commonly used prosthesis in the region. Since 1990 the number of patients registered with rheumatoid arthritis has fallen by almost 50%. During this period there has also been a slight decrease in the proportion of uncemented joints and a decline in the number of bilateral simultaneous procedures taking place. The ratio of primary to revision knee arthroplasty has not changed significantly since 1992 but there is some evidence of specialisation of revision knee surgery. There has been no significant change in patient satisfaction rates since the start of the registry, with 80% of patients reporting that they are satisfied with their joint replacement at 1 year.
Cerebral micro emboli have been noted to occur during both total hip and knee arthroplasty. These micro emboli have been implicated in the causation of postoperative cognitive impairment. The aim of this study was to determine whether cerebral micro emboli occur during hip fracture surgery. 28 patients undergoing hip fracture surgery had transcranial doppler assessment of the middle cerebral artery to detect cerebral micro emboli. Micro embolic signals (MESs) were recorded during the operative procedure. Successful monitoring was carried out in 26 patients. MES were recorded in 16 out of 26 patients. 12 out of 16 patients who had MESs had undergone a cemented hemiarthroplasty; the remainder had a sliding hip screw for an extracapsular hip fracture. 75% (9/12) of patients who had a cemented hemiarthroplasty had the majority of MESs after reaming and cementing. MESs in the patients who had a sliding hip screw occurred throughout the operative procedure.
We matched 78 patients with a loose cemented Charnley Elite Plus total hip replacement (THR) by age, gender, race, prosthesis and time from surgery with 49 patients with a well-fixed stable hip replacement, to determine if poor bone quality predisposes to loosening. Clinical, radiological, biomechanical and bone mineral density indicators of bone quality were assessed. Patients with loose replacements had more pain, were more likely to have presented with atrophic arthritis and to have a history of fragility fracture, narrower femoral cortices and lower peri-prosthetic or lumbar spine bone mineral density (all In this series of cemented hip replacements performed between 1994 and 1998, aseptic loosening was associated with poor bone quality. Patients with a THR should be screened for osteoporosis and have regular radiological surveillance.