In 2009, a multidisciplinary team of orthopaedic surgeons, material scientists, and cell biologists created a consortium focused on developing novel biomaterials for cartilage regeneration. After years of hard work across scientific boundaries, the team discovered a solution that could benefit a large number of patients. However, the research team was faced with a question on how to proceed. Whether to continue the scientific path of unravelling the mysteries of cartilage regeneration or to focus on bringing the invention from bench to bedside? The latter would mean commercialisation of the invention, and for the scientists, taking a completely new career path. Taking this turn would mean risking the team members' scientific career, since running a start-up would inevitably mean lesser publications and other scientific merits in the forthcoming years. On the other hand, there was the potential to help a vast amount of patients. The team decided that the invention, a biodegradable weight-adaptive medical device for cartilage regeneration, was too promising to be left aside, so they made the choice to transform from academic researchers to entrepreneurs. Thus, Askel Healthcare Ltd was founded in March 2017. For a start-up operating in medical device sector, the company has a unique feature: the founding team is all-female. Not intentionally, but by a mere “side effect” of gathering the best talents to get the job done. The team continues to foster its strong scientific background, which is a true asset for a company focusing on tackling the big unmet medical need of cartilage regeneration.
For a meaningful evaluation of biomaterials, Commercial Hyalograft® and ChondroGide® scaffolds were compared to a new experimental recombinant human collagen-PLA (rhCo-PLA) [1] and pure PLA scaffolds under BEST protocol [2] in pseudostatic (creep), dynamic (frequency scans, strain sweeps), and combined conditions (simulated operative periods) relevant for orthopaedic applications. Temperatures 25–37°C, dry and fully immersed wet (water, 0.9% NaCl) conditions were analysed and aggregate, complex dynamic moduli and loss factor were obtained. Additionally a method was developed for estimation of the swelling pressure under variable compression. ChondroGide and rhCo-PLA were compared All scaffold materials have a non-linear and non-uniform behaviour when immersed in a fluid, accompanied by rapid change in starting porosity (down for Hyalograft® and ChondroGide®, up for PLA), but nearly stable for rhCo-PLA. Too hydrophilic materials exhibited partial non-wetting (dry spots) under a slight compression eventually by closure of the specimen rim due to elastocapillary effect, where as hydrophobic (PLA) shown substantial expansion. The swelling pressure of PLA was measured of ∼1 kPa (water, 25°C). Observed creeping cannot be reliably fit with simple viscoelastic models, but can be approximated with biphasic theory with variable complex moduli and permittivity values. No significant differences were observed in creep for 1 h and 5 h runs, showing that a shorter time is sufficient to catch the main effects in these biomaterials. No substantial differences were observed between water and NaCl solution at 37°C, except for ChondroGide® which swells in NaCl more than in water. Besides of some differences in swelling, no significant differences observed between 25 and 37°C tests for creep. For dynamic conditions all materials undergo densification and “stiffening” (50% and more) upon cyclic strain deformation, with the effect being higher at 37°C than at 25°C. rhCo-PLA scaffolds exhibit relatively stable modulus in water and loss factor with physiologically-compatible behaviour (∼0.1 with a minimum values range around 1 Hz) at frequency scans (0.01–20 Hz). On the contrary, ChondroGide® has the highest loss factor (up to 0.6–0.7). Water at 25°C seems to be sufficient to rapidly test these kinds of materials for biomechanical screening, unless additions or specific effects are of interest. The applied deformation level is more important to predict materials properties in dynamic conditions than experiment time. This means that better