Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
Research

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_4 | Pages 1 - 1
1 Jan 2013
Harrowell I Gower J Robson-Brown K Luo J Annesley-Williams D Adams M Dolan P
Full Access

Introduction

Vertebroplasty helps to restore mechanical function to a fractured vertebra. We investigated how the distribution of injected cement benefits both fractured and neighbouring vertebrae.

Methods

Nine pairs of three-vertebra cadaver spine specimens (aged 67–90 yr) were compressed to induce fracture. One of each pair underwent vertebroplasty with PMMA, the other with a resin (Cortoss). Specimens were then creep-loaded at 1.0kN for 1hr. Before and after vertebroplasty, compressive stiffness was determined, and stress profilometry was performed by pulling a pressure-transducer through each disc whilst under 1.0kN load. Profiles indicated intradiscal pressure (IDP) and compressive load-bearing by the neural arch (FN) at both disc levels. Micro-CT was used to quantify cement fill in the anterior and posterior halves of each augmented vertebral body, and also in the region immediately adjacent to the fractured endplate