Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 34 - 34
23 Apr 2024
Duguid A Ankers T Narayan B Fischer B Giotakis N Harrison W
Full Access

Introduction

Charcot neuroarthropathy is a limb threatening condition and the optimal surgical strategy for limb salvage in gross foot deformity remains unclear. We present our experience of using fine wire frames to correct severe midfoot deformity, followed by internal beaming to maintain the correction.

Materials and Methods

Nine patients underwent this treatment between 2020–2023. Initial deformity correction by Ilizarov or hexapod butt frame was followed by internal beaming with a mean follow up of 11 months. A retrospective analysis of radiographs and electronic records was performed. Meary's angle, calcaneal pitch, cuboid height, hindfoot midfoot angle and AP Meary's angle were compared throughout treatment. Complications, length of stay and the number of operations are also described.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 15 - 15
1 May 2021
Debuka E Peterson N Fischer B Birkenhead P Narayan B Giotakis N Thorpe P Graham S
Full Access

Introduction

Methoxyflurane can cause hepatotoxicity and nephrotoxicity at anaesthetic doses but has excellent analgesic properties and no nephrotoxic effects in patients without preexisting disease. Approved for use in the UK and Ireland in 2015, it is currently being used in emergency departments for analgesia during fracture reduction. During the Covid emergency, with theatre access severely restricted and many patients unwilling to use inhaled Nitrous oxide, Penthrox had the potential to provide adequate pain relief to aid frame removals and minor procedures in the clinic.

Materials and Methods

Patients presenting to the Limb Reconstruction Unit Elective clinic and requiring frame removal or minor procedures were included in the study. Patients with renal, cardiac or hepatic disease, history of sensitivity to fluorinated anaesthetic agents and those on any nephrotoxic or enzyme inducing drugs were excluded. Verbal consent was obtained, the risks and benefits explained and the procedure was done in a side room in the clinic. Besides patient and procedure details, the Visual Analog Score and Richmond Agitation Scale was noted and patient's satisfaction documented. The results were presented as numbers, means and averages.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_10 | Pages 16 - 16
1 Jul 2014
Tang L Harrison W Holt N Narayan B Nayagam S Giotakis N
Full Access

Calcium sulphate (CaSO4) is a recognised form of delivery of antibiotic for the treatment of bone infection. Complications inherent in the rapid reabsorption are well recognised (predominantly that of wound breakdown and leakage). There is little data on the frequency of these complications. The purpose of this study was to quantify the incidence of wound leakage from CaSO4 and the service impact in orthopaedic surgery.

Infective limb reconstruction cases managed with gentamicin impregnated CaSO4 between 2004–2012 were identified. Co-morbidities and factors influencing wound leakage were recorded. Medical and wound care notes were analysed. Episodes of delayed discharge and unscheduled clinic attendance due to wound leakage were recorded.

80 patients (18 female, 62 male), with a mean age of 45 years (18–80 years, median 46 years) underwent 84 procedures utilising CaSO4. 47 were in the tibia, 14 in the femur, 10 in the humerus. A mean of 36 mL (4–150 mL, median 22 ml, unknown in 18 cases) was used.

31 cases (37%) had post-operative wound leakage, the majority from the tibia(55%) and femur(25%). 21 cases (25%) leaked within the first week. Each 10 ml rise in CaSO4 volume lead to a 50% rise in leakage incidence. Leak duration ranged from 4 days–10 months. The majority leaked between 1–4 months before ceasing spontaneously and without specific treatment.

14 cases (17%) required a cumulative 32 unscheduled clinic appointments for leakage. Further surgery was required for infection in 7 cases (8.3%). Delayed discharge was not clearly attributable to CaSO4. The mode of skin closure and cultured organism did not affect leakage.

CaSO4 has unpredictable leakage, but is present in 1/3 of patients. Volume of CaSO4 impacts on leakage. Leakage usually self-resolves and does not clearly impact on final outcomes. The cost impact of ongoing wound care and additional clinic appointments may be substantial.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_10 | Pages 13 - 13
1 Jul 2014
Grewal I Borbora A Giotakis N Nayagam S Vinjamuri S Narayan B
Full Access

The purpose of this study was to investigate the usefulness of PET-CT in the diagnosis and treatment of long bone infections following trauma.

All patients referred to the limb reconstruction service for management of non-unions were treated by the same protocol. PET-CT with FDG was performed in all patients to assess if the non-union site was infected and if so, the extent of the infection. Those requiring operative management were treated in a 2-stage manner. Initially with debridement based on PET-CT; sampling for microbiology and histology; and then Teicoplanin and Ciprofloxacin. If samples were positive then the patients were treated for a total of 6 weeks with antibiotics based on microbiology advice before undergoing definitive fixation. The sensitivity, specificity, PPV, and NPV were then calculated for PET-CTs ability to predict presence of infection using extended cultures and histology as the gold standard.

38 consecutive patients underwent surgery, 24 male and 14 female. 24 were deemed infected on extended culture or histology. PET-CT was anecdotally found to be extremely useful at determining the extent of infection to plan debridement.

PPV 0.83

NPV 0.89

Sensitivity 0.96

Specificity 0.61

As well as providing unique ability to demarcate areas of bony infection in the presence of metalwork, the ability to detect or exclude infection was exceptional.

This is a test, however, which is operator dependent and requires a skilled Nuclear Radiology Consultant to accurately interpret images. In our relatively small pilot study the accuracy improved noticeably over one year.

PET-CT has potential to be a powerful tool in the diagnosis and treatment of long bone infection following trauma and certainly warrants further investigation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 50 - 50
1 Sep 2012
Roche A Selvaratnam V Mukhopadhaya S Unnikrishnan N Abiddin Z Narayan B Giotakis N Aniq H Nayagam S
Full Access

Introduction

The treatment of chronic osteomyelitis involves a debridement of affected non-viable tissue and the use of antibiotics. Where surgery leaves a cavity, dead space management is practised with antibiotic impregnated cement. These depots of local antibiotics are variable in elution properties and need removal. We review the use of bioabsorbable synthetic calcium sulphate as a carrier of gentamicin and as an adjunct in treating intramedullary osteomyelitis.

Methods

A retrospective review of cases treated consecutively from 2006 to 2010 was undertaken. Variables recorded included aetiology, previous interventions, diagnostic criteria, radiological features, serology and microbiology. The Cierney-Mader system was used to classify. Treatment involved removal of implants (if any), intramedullary debridement and local resection (if needed), lavage and instillation of the gentamicin carrier, supplemented with systemic antibiotics. Follow-up involved a survival analysis to time to recurrence, clinical and functional assessment (AOFAS-Ankle/IOWA knee/Oxford Hip) and general health outcome (SF36).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 17 - 17
1 Jul 2012
Roche A Selvaratnam V Mukhopadhaya S Unnikrishnan N Abiddin Z Narayan B Giotakis N Aniq H Nayagam S
Full Access

The treatment of chronic osteomyelitis involves a debridement of affected non-viable tissue and the use of antibiotics. Where surgery leaves a cavity, dead space management is practised with antibiotic impregnated cement. These depots of local antibiotics are variable in elution properties and need removal. We review the use of bioabsorbable synthetic calcium sulphate as a carrier of gentamicin and as an adjunct in treating intramedullary osteomyelitis.

A retrospective review of cases treated consecutively from 2006 to 2010 in the Royal Liverpool University Hospital was undertaken. Variables recorded included aetiology, previous interventions, diagnostic criteria, radiological features, serology and microbiology. The Cierney-Mader system was used to classify. Treatment involved removal of implants (if any), intramedullary debridement and local resection (if needed), lavage and instillation of the gentamicin carrier, supplemented with systemic antibiotics. Follow-up involved a survival analysis to time to recurrence, clinical and functional assessment (AOFAS-Ankle/IOWA knee/Oxford Hip) and general health outcome (SF36).

There were 31 patients (22 male, 9 female). The mean age was 47 years (20-67). Twenty-five cases were post-surgery (6 open fractures) and 6 were haematogenous in origin. The median duration of osteomyelitis was 1.6yrs. The bones affected were 42% femur, 45% tibia, 3% radius and 10% humerus. 11 cases had diffuse as well as intramedullary involvement. 9 cases underwent segment resection and bone transport. We identified Staphylococcus Aureus in 16 and Coagulase Negative Staphylococcus in 6 cases. The median follow-up was 1.7 years (0.5-5.6). The median scores attained were: AOFAS-78, DASH-32, IOWA-71, Oxford-32. There were two recurrences.

Dead space management of intramedullary infections is difficult. We describe a method for delivery of local antibiotics and provide early evidence to its efficacy. The treatment success to date is 93%.

Bioabsorbable carriers of antibiotics are efficacious adjuncts to surgical treatment of intramedullary osteomyelitis.