Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Bone & Joint Research
Vol. 7, Issue 2 | Pages 166 - 172
1 Feb 2018
Bujnowski K Getgood A Leitch K Farr J Dunning C Burkhart TA

Aim

It has been suggested that the use of a pilot-hole may reduce the risk of fracture to the lateral cortex. Therefore the purpose of this study was to determine the effect of a pilot hole on the strains and occurrence of fractures at the lateral cortex during the opening of a high tibial osteotomy (HTO) and post-surgery loading.

Materials and Methods

A total of 14 cadaveric tibias were randomized to either a pilot hole (n = 7) or a no-hole (n = 7) condition. Lateral cortex strains were measured while the osteotomy was opened 9 mm and secured in place with a locking plate. The tibias were then subjected to an initial 800 N load that increased by 200 N every 5000 cycles, until failure or a maximum load of 2500 N.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 65 - 65
1 Mar 2012
Getgood A McNamara I Kili S Bhullar T
Full Access

Introduction

The aim of this study was to investigate whether methylene blue dye, commonly used in sterile surgical marker pens, would have an effect on human chondrocyte viability, when cultured on a collagen membrane in-vitro.

Methods

Bilayered collagen membranes were seeded in duplicate with 12 million human chondrocytes per ml and cultured for 24 hours under standard conditions. Group A consisted of a membrane marked with methylene blue ink on its smooth side, group B marked on its porous side, and group C acting as an unmarked control. At the end of the culture period the membranes were qualitatively analysed for cell survival by live/dead fluorescent staining under confocal microscopy.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 66 - 66
1 Mar 2012
Getgood A Henson F Lynn A Fortier L Brooks R Rushton N
Full Access

Introduction

The purpose of this study was to investigate whether combining PRP or concentrated bone marrow aspirate (CBMA) with a biphasic collagen/glycosaminoglycan (CG) scaffold would improve the outcome of the treatment of full thickness osteochondral defects in sheep.

Materials and Methods

Osteochondral defects (5.8×6mm) were created in the medial femoral condyle (MFC) and the lateral trochlea sulcus (LTS) of the stifle joints of 24 sheep. Defects were either left empty or filled with a 6×6mm CG scaffold, either on its own or in combination with PRP or CBMA (n=6). At 6 months the sheep were euthanised, and the repair tissue subjected to mechanical testing, gross morphological analysis, semi quantitative histological scoring and immunohistochemical staining including types I, II and VI collagen.