Vol. 105-B, Issue SUPP_12 | Pages 79 - 79
23 Jun 2023
Paprosky W Gerlinger T
Full Access

Previous reports on the outcomes of isolated head and liner exchange in revision total hip arthroplasty have found high rates of instability following these surgeries. Most reports have studied constructs using ≤28mm femoral heads. The purpose of this study was to determine if modern techniques with the use of larger head sizes can improve the rate of instability after head and liner exchange.

We identified 138 hips in 132 patients who underwent isolated head and liner exchange for polyethylene wear/osteolysis (57%), acute infection (27%), metallosis (13%), or other (2%). All patients underwent revision with either 32mm (23%), 36mm (62%), or 40mm (15%) diameter heads. Crosslinked polyethylene was used in all revisions. Lipped and/or offset liners were used in 104 (75%) hips. Average follow up was 3.5 (1.0–9.1) years. Statistical analyses were performed with significance set at p<0.05.

Revision-free survivorship for any cause was 94.6% and for aseptic causes was 98.2% at 5 years. 11 (8%) hips experienced a complication with 7 (5%) hips requiring additional revision surgery. Following revision, 4 (3%) hips experienced dislocation, 5 (4%) hips experienced infection, and 1 (1%) hip was revised for trunnionosis. No demographic or surgical factors significantly affected outcomes.

Our study shows that isolated head and liner exchange using large femoral heads and modern liners provides for better stability than previous reports. The most common complication was infection. We did not identify specific patient, surgical or implant factors that reduced the risk of instability or other complication.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 7 - 7
1 Aug 2018
Calkins T Culvern C Nam D Gerlinger T Levine B Sporer S Della Valle C
Full Access

The purpose of this randomized controlled trial is to evaluate the efficacy of using dilute betadine versus sterile saline lavage in aseptic revision total knee (TKA) and hip (THA) arthroplasty to prevent acute postoperative deep periprosthetic joint infection (PJI).

Of the 450 patients that were randomized, 5 did not have 90-day follow-up, 9 did not receive the correct treatment, and 4 were excluded for intraoperative findings consistent with PJI. 221 Patients (144 knees and 77 hips) received saline lavage only and 211 (136 knees and 75 hips) received a three-minute dilute betadine lavage (0.35%) prior to wound closure. Patients were observed for the incidence of acute postoperative deep PJI within 90 days of surgery. Statistical analysis was performed using t-tests or Fisher's exact test where appropriate. Power analysis determined that 285 patients per group are needed to detect a reduction in the rate of PJI from 5% to 1% (alpha=0.05, beta=0.20).

There were seven PJIs in the saline group and one in the betadine lavage group (3.2% vs. 0.5%, p=0.068). There were no significant differences in any baseline demographics between groups suggesting appropriate randomization.

Although we believe the observed difference between treatments is clinically relevant, it was not statistically significant with the sample size enrolled thus far and enrollment is ongoing. Nonetheless, we believe that these data suggests that dilute betadine lavage is a simple method to reduce the rate of acute postoperative PJI in patients undergoing aseptic revision procedures.