Medial column insufficiency in patients with painful acquired flatfoot can be difficult to appreciate. The reverse Coleman block test is used in this study to predict medial column instability. Patients who underwent a procedure for medial column insufficiency with use of the reverse Coleman block test pre-operatively were investigated. Weight bearing radiographs were used to determine the joints in the medial column contributing to the deformity and also to estimate the angle which the first ray must be depressed to re-establish hindfoot neutrality. The reverse Coleman block test corrects a mobile valgus heel to a neutral position by placing a block, of appropriate height, under the first metatarsal head. With the heel in neutral and the relative forefoot supination compensated the foot returns to a neutral anatomic position. Gender, age, complications and radiological outcomes were investigated.Introduction
Methods
Medial column insufficiency in patients with painful acquired flatfoot can be difficult to appreciate. The reverse Coleman block test (as described and published by Mr E Wood in 2009) is used in this study to predict medial column instability. Patients who underwent a procedure for medial column insufficiency with use of the reverse Coleman block test pre-operatively were investigated. Weight bearing radiographs were used to determine the joints in the medial column contributing to the deformity and also to estimate the angle which the first ray must be depressed to re-establish hindfoot neutrality. The reverse Coleman block test corrects a mobile valgus heel to a neutral position by placing a block, of appropriate height, under the first metatarsal head. With the heel in neutral and the relative forefoot supination compensated the foot returns to a neutral anatomic position. Gender, age, complications and radiological outcomes were investigated.Introduction
Methods
The aim of the study was to assess the clinical, radiological and paedobarographic outcome following modified Silver’s McBride’s procedure, in the treatment of Hallux Valgus. Between 1997 and 1999, Modified Silver’s McBrides procedure for Hallux Valgus was performed on 38 foot in 28 patients (18 unilateral and 10 bilateral). The median age was 60 years. The median follow up was 26 weeks. Clinical outcome measures consisted of pain, deformity, mobility, walking ability and shoe wear. Radiological outcome measures were Hallux Valgus angle, Intermetatarsal angle, 1st to 5th Metatarsal distance, 1st to 2nd metatarsal distance, and the DMAA (Distal Metatarsal Articular Angle). Paedobarographic (Musgrave) outcome of peak pressure, total force, time from heel strike to toe lift off post operatively were analysed. Preoperative visual analogue pain score was 5–8 and 0–4 postoperatively (p<
0.001). 34 feet had pain on walking preoperatively and only 11 had pain post-operatively. 12 were wearing special shoes pre- operatively and 5 post-operatively. Hallux Valgus angle was 34 pre-operatively and 19 post-operatively (p<
0.001). IMT angle was 14.53 pre-op and 10.88 postop (p<
0.001). 1st-5th MT distance was 67mm pre- op and 63mm post-op (p=0.001). 1st-2nd MT distance was 15 pre-op and 10 post-op (p=0.004). DMAA was 24.7 degrees. 21 foot an obliquity of the 1st tarsometatarsal joint was seen indicating an anatomical cause of metatarsus varus. Foot pressure studies showed a peak pressure of 1.37kg/cm2 , heel to toe off- time was 936.9ms and maximum load was 65.2 kg. There were 3 cases of superficial wound problems. One patient developed Hallux varus deformity, with no functional disability.
Blood flow at heart level
Up to 75% of patients develop metalwork related problems following ankle fracture fixation and require further open surgery to remove them. This second procedure can lead to significant morbidity. To minimise these complications, we developed a technique, for removing the metalwork percutaneously. This technique was used in 12 patients with metalwork problems related to malleolar implants. The majority of problems occurred with the distal fibular plate and the screws. One stab incision was placed mid way between every two screws so that two screws could be removed though one incision. The plate was stripped from the distal fibula using a narrow osteotome and extracted through the distal or proximal stab wound. Lag screws were also removed through an anterolateral stab incision. When we were unable to palpate the screw head, we used a guide wire under image intensifier to locate the screw head and railroaded a cannulated screwdriver over the wire to lock into the head of the screw. Medial malleolar screws were removed in a similar fashion. The technique was undertaken as day case surgery. No complications were encountered. All patients remained symptom-free postoperatively. We conclude that percutaneous removal of metalwork around ankle joint is a safe and effective technique, allowing the patient to quickly regain their preoperative level of activity.
Numerous techniques have been described for ankle arthrodesis. Arthroscopic arthrodesis with internal fixation has evolved to reduce the complications associated with open arthrodesis. We present our technique of arthroscopic ankle fusion using two medial cannulated screws with specially designed dished washers The tibiotalar joint is debrided arthroscopically and internal fixation is achieved with two medial cannulated screws with designed dished washers. Seven ankle arthrodeses were performed on six patients; one underwent bilateral arthrodesis. All the patients suffered from OA (four post traumatic) and were aged between 53–61 (mean 55.4). There were four males and two females. The follow up ranged from 8–18 months (mean 10). All the patients achieved ankle fusion. Time for fusion ranged from 6 to 18 weeks, five fused within 12 weeks. Pre operative pain scores improved from 6–10 out of 10 (mean 7.2) to 1–3 out of 10 (mean 1.4) post-operative. Post-operative AAFOS ankle hind foot score ranged from 74–89 out of 100 (mean 81.8). One patient required further operations for adjustment of fixation and one suffered a stress fracture at the level of the proximal screw. This method of arthroscopic ankle fusion provides an effective alternative to open arthrodesis for selected patients with OA achieving good initial results.
The existence of various techniques of ankle arthrodesis shows that there are pros and cons in each method. We describe our experience of ankle arthrodesis using a paediatric angle blade plate.
10 ankle arthrodeses were performed in nine patients. All patients were reviewed independently in special clinics. The objective assessment was performed by detailed clinical examination and the subjective assessment was made including overall patient satisfaction. The American Orthopedic Foot and Ankle Society ankle/hind foot scoring system was used. The technique of ankle arthrodesis was similar in all patients using an anteromedial or anterolateral incision, preparation of articular surface and paediatric angle blade plate fixation with or without bone grafting. Time to union was assessed by clinical and radiological examinations.
Radiological union was achieved in nine patients in a mean time of 16 weeks. Fibrous union occurred in one patient. Eight patients were very satisfied with their treatment. The patient with fibrous union had a marginal improvement of symptoms with pain score improved from nine to seven. The mean AOFAS score was 84.
Ankle arthrodesis with a paediatric angle blade plate is a useful method of managing intractable cases of ankle arthritis. The technique is simple and effective with excellent success rate.
Two cases are reported of the late diagnosis of compartment syndrome secondary to alcohol and drug overdose. Surgical decompression at two and a half days and at six days, respectively, produced worthwhile recovery. Other reports are reviewed and a case is made for the value of decompression even when performed late, and for delayed and minimal excision of apparently necrotic muscle.