Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 149 - 149
1 May 2016
De Martino I Sculco P Galasso O Gasparini G
Full Access

Introduction

The optimal management of severe tibial and/or femoral bone loss in a revision total knee arthroplasty (TKA) has not been established. Reconstructive methods include structural or bulk allografts, impaction bone-grafting with or without mesh augmentation, custum prosthetic components, modular metal augmentations of prosthesis and tumor prosthesis. Recently metaphyseal fixation using porous tantalum cones (Zimmer, Warsaw, IN) has been proposed as alternative strategy for severe bone loss.

Objectives

The purposes of this study were to determine the clinical and radiographic outcomes in patients who underwent revision knee arthroplasty with tantalum cones with a minimum of 5-year follow-up.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 144 - 144
1 May 2016
Galasso O Balato G Catania M Gasparini G Mariconda M
Full Access

Introduction

The use of antibiotic-loaded polymethylmethacrylate bone-cement spacers during two-stage exchange procedures is the standard in the treatment of patients with delayed prosthetic joint infection. The real antimicrobial activity of these spacers is unclear because the adherence of bacteria to cement might result in clinical recurrence of infection. The purpose of the study is to evaluate the in vitro formation of Pseudomonas Aeruginosa (PA) and Staphylococcus spp. biofilm on antibiotic-loaded bone cement.

Materials and methods

Cement disks (diameter = 6 mm) impregnated with gentamicin and colistin were submerged in bacterial suspensions of Methicillin-resistant Staphylococcus Aureus(MRSA), Staphylococcus epidermidis (SE), and PA. Negative controls (specimen disks without antibiotic) were similarly prepared. Biofilm formation was visualized by confocal scanning laser microscopy (CSLM), after staining the discs with the live/dead BacLight viability stain containing SYTO 9 dye and propidium iodide. Images from five randomly selected areas were acquired for each disc. Sequential optical sections of 2 µm were collected in sequence along the z-axis over the complete thickness of the sample. The resulting stacks of images were analyzed, quantified and rendered into three-dimensional (3D). The biofilm thickness on antibiotic bone cement compared with the controls was automatically evaluated.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 145 - 145
1 Jan 2016
Galasso O De Gori M Russo R Gasparini G
Full Access

High-dose antibiotic-loaded acrylic cement (ALAC) is used for managing periprosthetic joint infections (PJIs). The marked increase in resistant high-virulence bacteria is drawing the attention of physicians towards alternative antimicrobial formulations to the routinely used antibiotics. To date, few studies simultaneously investigated the elution properties of a broad range of antibiotics. The aim of thepresent in-vitrostudy was to determine the elution kinetics of 14 different high-dose ALACs.

All the ALAC samples showed a burst release of antibiotics in the first hour, progressively decreasing overtime, and elution curves strictly adhered to a non-linear regression analysis formula. Among aminoglycosides, commonly addressed as the most appropriate antibiotics to be loaded into the bone cement, the highest elution rate was that of tobramycin. Among the glycopeptides, commonly used to treat PJIs because of the prevalence of aminoglycoside resistance, vancomycin showed better elution in comparison with teicoplanin. Clindamycin, that can be associated with aminoglycosides to prepare ALACsshowed the highest absolute and relative elutions among all the tested formulations. A noticeable elution was also detected for colistin, an antibiotic of last resort for treating multi-drug resistant bacteria.

The current study demonstrates theoretical advantages in the preparation of ALAC for some antibiotics notroutinely used in the clinical setting for PJIs. The use of these antibiotics based on the infecting bacteria sensitivity may represent an useful option for physicians to eradicate PJIs. In vivo testing should be considered in the future to confirm the results of this study.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 319 - 319
1 Dec 2013
Galasso O Gasparini G Castricini R Mastroianni V
Full Access

BACKGROUND:

Few studies have evaluated at a medium-term follow-up the use of semiconstrained reverse shoulder arthroplasty (RSA) for primary glenohumeral osteoarthritis, massive rotator cuff tear, or cuff tear arthropathy excluding any other shoulder disease. Moreover, data on patients' quality of life after this surgery are lacking.

METHODS:

In this prospective cohort study, 80 patients were evaluated after an RSA for either primary osteoarthritis, massive rotator cuff tear, or cuff tear arthropathy with the Constant-Murley score (CMS), ROM, and Short Form Health Survey (SF-36). A radiologic assessment was performed pre- and postoperatively.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 315 - 315
1 Dec 2013
Galasso O Mariconda M Sticozzi M Gasparini G
Full Access

BACKGROUND:

Modern total hip arthroplasty (THA) has shown a great improvement in pain, function and range of motion of patients but data on patients' quality of life after this surgery as assessed by validated tools are lacking.

METHODS:

In this cohort study we evaluated the quality of life and functionality of 250 patients an average of 16 years (11–23) after THA using the SF-36 questionnaire, the Harris Hip Score, the WOMAC score, the Functional Comorbidity Index, and a study specific questionnaire. Models of multiple stepwise linear and logistic regression analysis were constructed to evaluate the relationships between the explanatory variables and the functional outcomes.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 180 - 180
1 Mar 2013
Gasparini G Guzzi P Pugliese T Galasso O
Full Access

The removal of cement debris at the time of primary and revision joint replacement has been facilitated through the introduction of coloured bone cements. Up to date, few studies have evaluated the effect of methilene blue dye on physical, mechanical and pharmacological properties of cements. In this light, we evaluated the effects of adding methylene blue to bone cement with or without antibiotics (gentamicin, vancomycin or both). The addition of methylene blue to plain cement significantly decreased its mean compression (95.4±3 MPa vs 100.1±6 MPa, p = 0.03) and bending (65.2±5 MPa vs 76.6±4 MPa, p < 0.001) strengths, mean setting time (570±4 seconds vs 775±11 seconds, p = 0.01), as well as its mean elastic modulus (2744±97 MPa vs 3281±110 MPa, p < 0.001). Bending resistance decreases after the supplementation of the coloured cement with vancomycin and gentamicin (55.7±4 MPa vs 65.2±5 MPa, p < 0.001). The release of antibiotics from the bone cement was significantly decreased by the methylene blue. Indeed, the release of gentamicin alone was 385.5±26 μg in comparison to 228.2±24 μg when the methylene blue was added (p < 0.001), while the release of gentamicin in combination with vancomycin was 613±25 μg vs 498.5±70 μg (p = 0.018) when the dye was added to the same formulation. With this study we demonstrated several theoretical disadvantages of the antibiotic-loaded bone cement coloured with methylene blue, although caution should be exercised in transferring our findings to the clinical context. Based on our findings, we do not recommend methylene blue supplementation of PMMA for routine clinical use.