Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 88 - 88
1 Dec 2016
Greidanus N Konan S Duncan C Masri B Garbuz D
Full Access

In revision total hip arthroplasty (THA), acetabular reconstruction while dealing with severe bone loss is a challenge. The porous tantalum revision acetabular shells have been in use for the past decade. Several reports have documented successful use at early to mid-term follow up. There is, however, very little literature around the long-term survival and quality of life outcome with the use of these shells.

We reviewed the results of 46 acetabular revisions with Paprosky 2 and 3 acetabular bone defects reconstructed with a hemispheric, tantalum acetabular shell and multiple supplementary screws. There were 31 females. Average age at revision was 64 years (range 23–85 years). The mean and median follow up was 11 years (range 10–12 years, SD 1). Morselised femoral allograft was used in 34 hips to fill contained cavitary defectes. Bulk femoral allografting was performed in 2 hips.

At a minimum follow-up of 10 (range 10–12) years, the survivorship of the porous tantalum acetabular shell, with revision of the shell as end point was 96%. The minimum 10-year survivorship with hip revision for any reason as end point was 92%. We noted excellent pain relief (mean WOMAC pain 92.6) and good functional outcome (mean WOMAC function 90.3, mean UCLA 5); and generic quality of life measures (mean SF-12 physical component 48.3; mean SF-12 mental component 56.7). Patient satisfaction with pain relief, function and return to recreational activities were noted to be excellent.

Cementless acetabular revision with the tantalum acetabular shell demonstrated excellent clinical and quality of life outcomes at minimum 10-year follow-up. As far as we are aware this is the first report of minimum 10-year follow up of use of this technique for revision hip arthroplasty.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 82 - 82
1 Dec 2016
Greidanus N Garbuz D Konan S Duncan C Masri B
Full Access

Revision surgery for pelvic discontinuity in the presence of bone loss is challenging. The cup-cage reconstruction option has become popular for the management of pelvic discontinuity in the recent years. The aim of this study was to review the clinical, radiological and patient reported outcomes with the use of cup cage construct for pelvic discontinuity at our institution.

Twenty-seven patients (27 cup-cage reconstructions) were identified at median 6-year (minimum 2 year, maximum 10 years) follow up. Eight were female patients. The median age was 77 years [mean 72, range 37–90, SD 13.6]. There were 5 deaths and 2 were lost to follow up.

Two patients were converted to excision arthroplasty; one for infection and one for failure of the construct. A further 3 patients required revision for instability but the cup cage construct was not revised (2 revisions of cemented cups to a constrained cup and one revision of proximal modular component of the femoral prosthesis). Revision of the cup cage construct was not necessary in any of these cases. We noted excellent pain relief (mean WOMAC pain 85.6) and good functional outcome (mean WOMAC function 78.2, mean UCLA 5, mean OHS 78.6). Patient satisfaction with regards pain relief; function and return to activities were noted to be excellent. Radiological changes were noted in further 4 patients (cup migration in one case; fracture of ischial spike in one case and breakage of the cage screws in 2 patients). No migration of the construct was noted in any of the cases.

In conclusion, the cup cage construct is an excellent method of dealing with complex pelvic discontinuity. Our study suggests a low failure rate; high patient satisfaction and pain relief and moderate functional outcome at median 6 year follow up.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 24 - 24
1 Feb 2012
Patil S Greidanus N Garbuz D Masri B Duncan C
Full Access

Introduction

Despite advances in surgical technique and prosthetics there continues to be a number of patients who are dissatisfied with the results of their knee replacement procedure. The outcome after total knee arthroplasty (TKA) has been reported frequently with use of condition-specific measures, but patient satisfaction has not been well studied.

Material and methods

160 patients who received primary total knee arthroplasty (TKA) were evaluated prospectively to evaluate factors that may be associated with patient satisfaction. At minimum one year follow-up all patients were evaluated and completed validated self-report satisfaction questionnaires. Patient, surgeon, implant and process of care variables were assessed along with WOMAC, Oxford Knee and SF-12 scores. Univariate and multivariate analyses were performed to assess for independent factors associated with post-operative satisfaction.