Non-union is an unfortunate outcome of the fracture healing process for some patients; with an estimated annual incidence of 17.4- 18.9 per 100,00. The management of these patients depicts a significant clinical challenge for surgeons and financial burden to health services. External ultrasound stimulation devices (ExogenTM) have been highlighted as a novel non invasive therapy to achieve union in cases of delayed and non-union. The aim of the current study was to assess the rate of union in patients using ExogenTM therapy for delayed fracture union in a district general hospital. This is a single centre retrospective continuous cohort study. Patients were identified from a prospective database of all patients prescribed ExogenTM therapy between June 2013- September 2021 in a district general hospital. Patient data was collected retrospectively using electronic patient records. Fracture union was assessed both clinically and radiographically and recorded in patient records. Failure of treatment was defined as progression to operative treatment due to lack of progression with ultrasound therapy or established asymptomatic non-union. Patient were excluded from the study if ExogenTM therapy was prescribed within 6 weeks of injury.Introduction
Materials & Methods
Local antimicrobial therapy is an integral aspect of treating orthopaedic device related infection (ODRI), which is conventionally administered via polymethylmethacrylate (PMMA) bone cement. PMMA, however, is limited by a suboptimal antibiotic release profile and a lack of biodegradability. In this study, we compare the efficacy of PMMA versus an antibioticloaded hydrogel in a single- stage revision for chronic methicillin-resistant sheep. Antibiofilm activity of the antibiotic combination (gentamicin and vancomycin) was determined There was a nonsignificant reduction in biofilm with an increasing antibiotic concentration in vitro (p = 0.12), confirming the antibiotic tolerance of the MRSA biofilm. In the in vivo study, four out of five sheep from each treatment group were culture negative. Antibiotic delivery via hydrogel resulted in 10–100 times greater local concentrations for the first 2–3 days compared with PMMA and were comparable thereafter. Systemic concentrations of gentamicin were minimal or undetectable in both groups, while renal and liver function tests were within normal limits. This study shows that a single-stage revision with hydrogel or PMMA is equally effective, although the hydrogel offers certain practical benefits over PMMA, which make it an attractive proposition for clinical use.
Implant-associated osteomyelitis is a devastating complication with poor outcomes following treatment, especially when caused by antibiotic-resistant bacteria such as methicillin-resistant 12 female, 2 to 4 year old, Swiss Alpine Sheep were inoculated with MRSA at the time of intramedullary nail insertion in the tibia to develop chronic osteomyelitis. After 8 weeks sheep received a 2-stage revision protocol, with local and systemic antibiotics. Group 1 received the gold standard clinical treatment: systemic vancomycin (2 weeks) followed by rifampicin plus trimethoprim/sulfamethoxazole (4 weeks), and local gentamicin/vancomycin via PMMA. Group 2 received local gentamicin/vancomycin delivered via THH at both revision surgeries and identical systemic therapy to group 1. Sheep were euthanized 2 weeks following completion of antibiotic therapy. At euthanasia, soft tissue, bone, and sonicate fluid from the hardware was collected for quantitative bacteriology.Aim
Method