Please check your email for the verification action. You may continue to use the site and you are now logged in, but you will not be able to return to the site in future until you confirm your email address.
Introduction: Bunnell suture technique is effective for tendon repair. A modification of the classic suture technique could increase ultimate failure point (UFP) on the suture-tendon site. The purpose of this study is to evaluate UFP of regular and modified Bunnell suture techniques on in vitro porcine patellar tendons.
Methods: Porcine patellar tendon samples (N=24) were used for this study, separating them in 2 groups: Group A: classic Bunnell suture on the tendon (N=12). Group B: two perpendicular Bunnell sutures at 90° between them on the tendon (N=12). After suturing the samples, axial traction until failure on the tendon-suture site was applied on samples of both groups documenting UFP with a tension sensor device. UFP was measured and described in Newtons for all samples. Statistics: Non parametric Mann-Whitney test for independent variables was used to analyze outcomes.
Results: The UFP for group A was 224 ± 38,9 N. The UFP for group B was 307 ± 19,9 N. We found statistical differences among groups (p=0,00006).
Discussion: In this study we analyzed the UFP of classic Bunnell suture technique vs. a modification adding a second Bunnell suture perpendicular to the classic technique. The purpose of this modification is to increase the contact area between the suture and the tendon, reaching a stronger disposition at suture-tendon site. This has been documented in the UFP values obtained.
Conclusion: Adding a perpendicular Bunnell suture run in porcine ex vivo patellar tendons increases UFP in tendon repair at tendon – suture site.