Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 49 - 49
1 Apr 2019
Harman C Afzal I Shardlow D Mullins M Hull J Kashif F Field R
Full Access

INTRODUCTION

Historically, the clinical performance of novel implants was usually reported by designer surgeons who were the first to acquire clinical data. Regional and national registries now provide rapid access to survival data on new implants and drive ODEP ratings. To assess implant performance, clinical and radiological data is required in addition to implant survival. Prospective, multi-surgeon, multi-centre assessments have been advocated as the most meaningful. We report the preliminary results of such a study for the MiniHip™femoral component and Trinity™ acetabular component (Corin Ltd, UK).

METHODS

As part of a non-designer, multi-surgeon, multi-centre prospective surveillance study to assess the MiniHip™stem and Trinity™ cup, 535 operations on 490 patients were undertaken. At surgery, the average age and BMI of the study group was 58.2 years (range 21 to 76 years) and 27.9 (range 16.3 to 43.4) respectively. Clinical (Harris Hip Score, HHS) and radiological review have been obtained at 6 months, 3 and 5 years. Postal Oxford Hip Score (OHS) and EuroQol- 5D (EQ5D) score have been obtained at 6 months and annually thereafter. To date, 23 study subjects have withdrawn or lost contact, 11 have died, and 9 have undergone revision surgery. By the end of March 2018, 6 month, 1, 2, 3, 4, and 5 year data had been obtained for 511, 445, 427, 376, 296 and 198 subjects respectively.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 22 - 22
1 Nov 2017
Dabis J Shaw T Hutt J Ward D Field R Mitchell P Sandiford A
Full Access

Introduction

Instability accounts for one third of revision total hip arthroplasty(rTHA) performed in the United Kingdom. Removal of well-fixed femoral stems in rTHA is challenging with a risk of blood loss and iatrogenic damage to the femur. The Bioball Universal Adaptor (BUA) (Merete, Germany), a modular head neck extension adaptor, provides a mechanism for optimisation of femoral offset, leg length and femoral anteversion. This can avoid the need for femoral stem revision in selected cases. There is a relative paucity of clinical data available with the use of this device.

Aim

The aim of this study is to present the clinical results and rate of instability following revision with this head neck adaptor at a minimum of two years' follow up.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 35 - 35
1 Jan 2013
Williams D Price A Beard D Hadfield S Arden N Murray D Field R
Full Access

Objectives

This study examines variations in knee arthroplasty patient reported outcome measures according to patient age.

Methods

We analysed prospectively collected outcome data (OKS, Eq5D, satisfaction, and revision) on 2456 primary knee arthroplasty patients. Patients were stratified into defined age groups (< 55, 55–64, 65–74, 75–84, and ≥85 years). Oxford Knee Score and Eq5D were analysed pre-operatively, and postoperatively at 6 months and 2 years. Absolute scores and post-operative change in scores were calculated and compared between age groups. Satisfaction scores (0–100) were analysed at 6 months post-operatively. Linear, logistic and ordinal regression modelling was used to describe the association between age and outcomes, for continuous, binary and ordinal outcomes, respectively. Kaplan-Meier analysis was performed to describe revision rates at 2 years.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 190 - 190
1 Jan 2013
Alazzawi S Bardakos N Hadfield G Butt U Beer Z Field R
Full Access

Using general practitioner records, hospital medical notes and through direct telephone conversation with patients, we investigated the accuracy of nine patient-reported complications after elective joint replacement surgery of the hip and knee. A total of 402 post-discharge complications were reported after 8546 elective operations that were undertaken within a three-year period. These were reported by 136 men and 240 women with an overall mean age of 71.8 years (34.3–93.2). A total of 319 (79.4%; 95% confidence interval, 75.4%–83.3%) reported complications were confirmed to be correct. Very high rates of correct reporting were demonstrated for infection (94.5%) and further surgery (100%), whereas the rates of reporting deep venous thrombosis (DVT), pulmonary embolism, myocardial infarct and stroke were lower (75%–84.2%). Dislocation, periprosthetic fractures and nerve palsy were associated with modest rates of correct reporting (36%–57.1%). More patients who had had knee surgery delivered incorrect reports of dislocation (p = 0.001) and DVT (p = 0.013). Despite these variations in accuracy, it appears that post-operative complications may form part of a larger patient-reported outcome programme for monitoring outcome after elective joint replacement surgery.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 23 - 23
1 Jan 2013
Strambi F Yeo A Riva G Buly J Hisole J Field R
Full Access

Introduction

Total hip arthroplasty (THA) is undertaken to relieve pain and to restore mobility. The orthopaedic community remains divided on the influence of surgical approach in achieving functional recovery most quickly and effectively. We report a study comparing THA performed through a posterior (Posterior) against anterior approach (Heuter).

Methods

Fifty patients were prospectively enrolled and randomized for Posterior or Heuter procedures. Informed patient consent and local ethics approval was obtained. All patients received an uncemented, ceramic-on-ceramic prosthesis performed by a single surgeon.

Functional outcome was assessed by time to achieve milestones of walking, stair climbing, hip movement and balance. Kinematic data on level-ground walking and the effect of fatigue was assessed using a portable gait analysis system at 6-, 12-, and 24-weeks post-operatively.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 262 - 262
1 Sep 2012
Alazzawi S Hadfield S Bardakos N Field R
Full Access

Introduction

The outcomes programme of our institution has been developed from a system first used at Epsom and St Helier NHS Trust 15 years ago. The system was implemented at our institution when it opened in 2004, and has been used to collect data on over 17,000 joint replacement operations so far. A bespoke database is used to collect, analyse and report outcome data.

Methods

An integrated system allows the collection of patient-reported outcome measures (PROMS), patient satisfaction scores, radiological assessment, and medical or surgical complications. Functionality allows the transfer of data from existing clinical management programmes, and the generation of customised letters and questionnaires to send to patients. Analysis of data and report production is fully automated. Data is collected pre-operatively, during the inpatient stay, and post-operatively at 6 weeks, 6, 12 and 24 months. Results are disseminated to the surgeons, the senior management team and the Clinical Governance Committee.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 263 - 263
1 Sep 2012
Buly J Hadfield S Bardakos N Field R
Full Access

Introduction

The need for the stringent surveillance of new devices was recognised by the NICE review of hip replacement surgery in 2000 and led to the Orthopaedic Data Evaluation Panel (ODEP) developing criteria for post-marketing surveillance (PMS) studies. This requirement has been reinforced by the recent recall of ASR devices.

Methods

The South West London Elective Orthopaedic Centre's (EOC's) comprehensive outcomes programme has been adapted to manage and coordinate multi-centre, multi-surgeon, PMS studies. The system allows any schedule and combination of patient-reported outcome measures (PROMS), clinical and radiological assessments, and complications to be collected. Typically, PROMS are collected pre-operatively and yearly by post. Baseline clinical assessment is undertaken pre-operatively, with baseline radiological assessments pre- and post-operatively. Subsequent clinical and radiological assessments are usually obtained at the ODEP-mandated time points of 3, 5, 7 and 10 years post-operatively. Patients are telephoned twice yearly to document complications and any impending change of address.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 126 - 126
1 Mar 2012
Moonot P Kamat Y Kalairajah Y Bhattacharyya M Adhikari A Field R
Full Access

The Oxford Knee Score (OKS) is a valid and reliable self-administered patient questionnaire that enables assessment of the outcome following total knee replacement (TKR). There is as yet no literature on the behavioral trends of the OKS over time. Our aim is to present a retrospective audit of the OKS for patients who have undergone TKR during the past ten years.

We retrospectively analysed 3276 OKS of patients who had a primary TKR and had been registered as part of a multi-surgeon, outcome-monitoring program at St. Helier hospital. The OKS was gathered pre-operatively and post-operatively by means of postal questionnaires at annual intervals. Patients were grouped as per their age at operation into four groups: 60, 61-70, 71- 80 and >80. A cross-sectional analysis of OKS at different time points was performed.

The numbers of OKS available for analysis were 504 pre-operatively, 589 at one-year, 512 at two-year and gradually decreasing numbers with 87 knees ten-year post-operatively. There was as expected a significant decrease (improvement) of the OKS between pre-operative and one-year post-operative period and then reached a plateau. Beyond eight years, there is a gradual rise in the score (deterioration). The younger patients (60) showed a significant increase in their average OKS between one and five-years post-operatively. However beyond five years, they followed the trend of their older counterparts. When the twelve questions in the OKS were analysed, certain components revealed greater improvement (e.g. description of knee pain and limping) than others (e.g. night pain).

The OKS is seen to plateau a year after TKR. According to the OKS the outcome of the TKR is not as good in the younger age group as compared to the older age group. Further investigation is required to ascertain the cause of this observed difference.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 118 - 118
1 Mar 2012
Moonot P Railton G Mu S Field R Banks S
Full Access

The performance of total knee arthroplasty in deeply flexed postures is of increasing concern as the procedure is performed on younger, more physically active and more culturally diverse populations. Several implant design factors, including tibiofemoral conformity, tibial slope and posterior condylar geometry have been shown directly to affect deep flexion performance.

The goal of this study was to evaluate the performance of a fixed-bearing, asymmetric, medial rotation arthroplasty design during kneeling activities.

Thirteen study participants (15 knees) with primary total knee arthroplasty (Medial Rotation Knee, Finsbury, Surrey, UK) were observed while doing a step activity and kneeling on a padded bench from 90° to maximum comfortable flexion using lateral fluoroscopy. Subjects averaged 74 years of age and nine were female. Subjects were an average of 17 months post-operative, and scored 94 points on the International Knee Score and 99 on the Functional Score. Digitised fluoroscopic images were corrected for geometric distortion and 3D models of the implant components were registered to determine the 3D position and orientation of the implants in each image.

During the step activity, the medial and the lateral femoral contact point stayed fairly constant with no axial rotation from 0 to 100° of flexion. At maximum kneeling flexion, the knees exhibited 119° of implant flexion (101°-139°), 7° (-7° to 17°) tibial internal rotation, and the lateral condyle translated backwards by 11 mm.

Patients with medial rotation knee arthroplasty exhibited medial pivot action with no paradoxical translation. The knees exhibited excellent kneeling flexion and posterior translation of the femur with respect to the tibia. The axial rotation in MRK was within the range of normal knee kinematics from -10 to 120 (perhaps 140).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 8 - 8
1 Feb 2012
Hamilton P Lemon M Field R
Full Access

Aims

To establish the cost of primary hip (THR) and knee (TKR) arthroplasty in an elective orthopaedic centre in the UK and to compare it with current government reimbursement to NHS hospitals and the costs in North America.

Methods

In 2004 an elective orthopaedic centre was set up in South West London which performs mainly primary lower limb arthroplasty. We used a retrospective analysis of financial statements from September 2004-June 2005 inclusive to establish operative costs (including implant), perioperative costs and post-operative costs until discharge.