Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 149 - 149
1 May 2016
Rieker C Hasgall P Ferrando M
Full Access

INTRODUCTION

Total joint arthroplasty continues to gain acceptance as the standard of care for the treatment of severe degenerative joint disease, and is considered one of the most successful surgical interventions in the history of medicine. However, infection of these implants, called Periprosthetic Joint Infection (PJI), remains one of the biggest challenges facing orthopaedics today. PJI can lead to additional surgeries, revision, fusion and amputation.

Diagnosis of PJI

It is important to accurately diagnose PJI because its management differs from that of other causes of arthroplasty failure. In acute infection, the local signs and symptoms (e.g., severe pain, swelling, erythema, and warmth at the infected joint) of inflammation are generally present. On the other hand, chronic infection usually has a more subtle presentation, with pain alone, and is often accompanied by loosening of the prosthesis at the bone-implant interface. The diagnosis of PJI has proven quite challenging, as both acute and chronic infections can be difficult to differentiate from other forms of inflammation.

The reported literature on the diagnosis of PJI has focused on evaluated laboratory tests that were never developed specifically for the diagnosis of PJI. These include the erythrocyte sedimentation rate (ESR), the serum C-reactive protein (CRP), the synovial fluid white blood cell count and the leukocyte differential. Because these tests were not made for the purpose of diagnosing PJI, it has been the responsibility of the orthopaedic community to evaluate and recommend their interpretation. This has resulted in significant confusion regarding the appropriate thresholds and optimal combination of these tests. These difficulties were the motivation for the development of a specific test for the detection of PJI.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 61 - 61
1 Dec 2015
Hasgall P Ferrando M Rieker C
Full Access

Total joint arthroplasty continues to gain acceptance as the standard of care for the treatment of severe degenerative joint disease. However, the Periprosthetic Joint Infection (PJI) remains one of the biggest challenges facing orthopaedics today.

It is important to accurately diagnose PJI because its management differs from that of other causes of arthroplasty failure. The most common symptom of PJI is pain. In acute infection, the local signs and symptoms (e.g., severe pain, swelling, erythema, and warmth at the infected joint) of inflammation are generally present. On the other hand, chronic infection usually has a more subtle presentation, with pain alone, and is often accompanied by loosening of the prosthesis at the bone-implant interface. The diagnosis of PJI has proven quite challenging, as both acute and chronic infections can be difficult to differentiate from other forms of inflammation.

The reported literature on the diagnosis of PJI has focused on evaluated laboratory tests that were never developed specifically for the diagnosis of PJI. Because these tests were not made for the purpose of diagnosing PJI, it has been the responsibility of the orthopaedic community to evaluate and recommend their interpretation. This has resulted in significant confusion regarding the appropriate thresholds and optimal combination of these tests. These difficulties were the motivation for the development of a specific test for the detection of PJI. The promising diagnostic capabilities of synovial fluid biomarkers for PJI have already been reported in the literature. Studies have demonstrated that the alpha-defensin microbicidal peptide present in human neutrophils is an ideal biomarker for PJI due to the distinct separation it achieves between positive and negative results.

A specific test allowing to measure the concentration of the alpha-defensin in the synovial fluid has been developed.

The specificity and the sensitivity of this test for the detection of a PJI are respectively 96% and 97%. This test has been proven to have also a high reproducibility, its results not being influenced by antibiotics.

A lateral flow version of this test (Synovasure PJI, distributed exclusively in Europe by Zimmer GmbH) has been recently developed. It allows reading the results in 10 minutes and it doesn't require any laboratories for its interpretation. Currently, this test device is in clinical evaluation in more than 200 European hospitals.

In case that the clinical evaluation of this test device is positive, this method will be a new paradigm for the diagnosis of periprosthetic joint infection.