Few reports were shown about the position of the cup in total hip arthroplasty (THA) with CT-based navigation system. We use minimally invasive surgery (MIS) technique when we perform cementless THA and the correct settings of cups are sometimes difficult in MIS. So we use CT-based navigation system for put implants with correct angles and positions. We evaluated the depth of cup which was shown on intra-operative navigation system. We treated 30 hips in 29 patients (1 male and 28 females) by navigated THA. 21 osteoarthritis hips, 6 rheumatoid arthritis hips and 3 idiopathic osteonecrosis hips were performed THA with VectorVision Hip 2.5.1 navigation system (BrainLAB). Implants were AMS HA cups and PerFix stems (Japan Medical Materials, Osaka). Appropriate angles and positions of cups were decided on the 3D model of pelvis before operation. According to the preoperative planning, we put the implants with navigation system. We correct the pelvic inclination angle and measured the depth of cups with 3D template software.Objectives
Materials and Methods
Many reports were shown about the angle of the cup in total hip arthroplasty (THA) with CT-based navigation system. However, there are few reports about the position of the stem. We investigated the position of the stem in navigated THA. We evaluated the position and alignment of stem which were shown on intra-operative navigation system. We treated 10 hips in 10 patients (1 male and 9 females) by navigated THA. 7 osteoarthritis hips and 3 idiopathic osteonecrosis hips were performed THA with VectorVision Hip 2.5.1 navigation system (BrainLAB). Implants were AMS HA cups and PerFix stems (Japan Medical Materials, Osaka). The positions of stem were decided on the 3D model of femur before operation. According to the preoperative planning, we put the implants with navigation system and recorded the position. We measured the position and alignment of stem with 3D template software after operation. We checked for complications.Objectives
Materials and Methods
ROBODOC is a well known tool for a computer assisted arthroplasty. However, the incision tends to enlarge with the system because of the restriction of range of motion. We have developed the robot system for minimally invasive arthroplasty. This report shows the accuracy of our system composed of original planning software, navigation and bone cutting robot. We took the DICOM data of cadaver knees from computed tomography. The data were transferred to the workstation for planning. Matching points for registration and cutting planes were determined on the planning software. Cutting tool was the 6th robot which was able to recognize the locations of its apex and the cadaver knee with navigation system. We made five planes for TKA and two planes for UKA on femur. Then we made one plane on tibia. We evaluated the accuracy by measurement the location of cutting plane under navigation system and by CT data. The registration errors of femur and tibia were less than 1.0mm about cadaver knees. The errors of cutting planes were 1.3 mm about the distal end of femur and 0.5 mm about the proximal end of tibia. The accuracies of the angles of cutting planes were 1.9 degrees and 0.8 degrees compared to the mechanical axis. The errors of anterior and posterior plane of femur were increased compared to the distal plane. It was because the accuracy of registration were correct in axial direction but was not satisfied in rotational direction. The error was considered by the location of points which decided the rotation alignment. We will make effort to minimize the errors of registration and put it into practical use as soon as possible.
Total Knee Arthroplasty (TKA) has been widely performed and successful clinical outcomes have been achieved for the patients with knee osteoarthritis which is generally known to cause ADL problem. Clinical and radiographic evaluations are commonly used when evaluating postoperative outcomes, among which kinetic analysis and gait analysis are considered essential to investigate the more detailed effect of the treatment. There is a controversy whether performing TKA on both knees simultaneously is appropriate in treating patients with bilateral knee osteoarthritis, in terms of the speed and effectiveness of gait recovery. In this study, we reviewed the significance of performing simultaneous bilateral TKA, by the results of preoperative and postoperative gait analysis.