Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 8 - 8
1 Jan 2018
Eachempati K Malhotra R Guravareddy A Ashokkumar P Gowtam D Sheth N Suryanarayan P
Full Access

The advent of trabecular metal (TM) augments has revolutionized the management of severe bone defects during acetabular reconstruction. The purpose of this study was to evaluate patients undergoing revision total hip arthroplasty (THA) with the use of TM augments for reconstruction of Paprosky 3A, 3B defects and defects associated with pelvic discontinuity.

A retrospective study was conducted of the cases performed at four centers between August 2007 and January 2015. Patients treated with TM augments for Paprosky 3A, 3B or chronic pelvic discontinuity were included in the study. All surgeries were performed through a posterior approach. A total of 57 patients (Male 34 (69%), Female 23(31%)), mean age 54 years (range, 28–94 years), with minimum follow up of one-year were included and evaluated using intention to treat analysis. There were 44 (77%) patients with a 3A defect, 11(19%) patients with a 3B defect (6 had an associated pelvic discontinuity), and 2 (3.5%) with a 2C defect and associated pelvic discontinuity. The mean follow-up was 37 months (range, 12–96 months). One (2%) patient died after 8 years of unrelated causes. Three (5.5%) patients had acetabular component loosening requiring revision; Two failures were (3.5%) due to aseptic loosening and one (2%) due to septic loosening. Fifty-four patients had a radiologically stable integration of the components at latest follow-up - survivorship was 94.7%.

The results of this multi-center study demonstrate encouraging short and mid-term results for the use of TM augments in the management of Grade 3A and 3B defects, and defects associated with a chronic pelvic discontinuity.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 113 - 113
1 May 2011
Malhotra R Kumar V Eachempati K Bhan S
Full Access

Background: Durable long-term independent results with the Low Contact Stress rotating-platform (mobile-bearing) and the Insall Burstein-II (fixed-bearing) total knee prostheses have been reported, but no studies describing either the mid-term or long-term results and comparing the two prostheses are available, to our knowledge.

Methods: Thirty-two patients who had bilateral arthritis of the knee with similar deformity and preoperative range of motion on both sides and who agreed to have one knee replaced with a mobile-bearing total knee design and the other with a fixed-bearing design were prospectively evaluated. Comparative analysis of both designs was done at a mean follow-up period of six years, minimizing patient, surgeon, and observer-related bias. Clinical and radiographic outcome, survival, and complication rates were compared.

Results: Patients with osteoarthritis had better function scores and range of motion compared with patients with rheumatoid arthritis. However, with the numbers available, no benefit of mobile-bearing over fixed-bearing designs could be demonstrated with respect to Knee Society scores, range of flexion, subject preference, or patellofemoral complication rates. Radiographs showed no difference in prosthetic alignment. Two knees with a mobile-bearing prosthesis required a reoperation: one had an early revision because of bearing dislocation and another required conversion to an arthrodesis to treat a deep infection.

Conclusions: We found no advantage of the mobile-bearing arthroplasty over the fixed-bearing arthroplasty with regard to the clinical results at mid-term follow-up. The risk of bearing subluxation and dislocation in knees with the mobile-bearing prosthesis is a cause for concern and may necessitate early revision.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 210 - 210
1 May 2011
Malhotra R Eachempati K Kumar V
Full Access

Introduction: The occurrence of bony ankylosis in ankylosing spondylitis (AS) is not precisely known. Bony ankylosis, especially in stiff spine may present several exclusive challenges in its management. The current study is an endeavor to evaluate the clinical and the radiological results of cementless THA in patients with bony ankylosis of hip due to ankylosing spondylitis.

Materials and Methods: We retrospectively reviewed 54 patients (92 hips) who underwent cementless total hip arthroplasty for bony ankylosis in ankylosing spondylitis between September 1988 and 2002. Clinical assessment was done at follow-up, which envisages assessment of the pain, function, deformities and range of motion using the Harris Hip Score. Radiographic analysis was done. Kaplan-Meier survivorship analysis was done at 5 and 8.5 years using the revision for the removal of femoral component, acetabular component or both due to any cause as the end point

Results: The mean age of the patients was 25.5 years. The mean duration of follow up was 8.5 years. The average preoperative Harris Hip Score of 49.5 improved to 82.6 post operatively. Post operatively 10 hips had mild to moderate pain. Anterior dislocation occurred in four hips (4.3 %) and sciatic nerve palsy in one hip. Heterotopic ossification was seen in 12 patients, reankylosis rate was 0%. Thirteen arthroplasties were revised due to aseptic loosening. Kaplan-Meier survivorship analysis with revision as end point revealed 98.8% survival at 5 years and 85.8% survival at 8.5 years 11 follow up

Discussion: Cementless THA in osseous ankylosis in ankylosing spondylitis is a worthwhile surgical intervention in bony ankylosis. Newfound mobility, maneuverability and improved ability to sit comfortably were the outcomes, which alleviated the patients’ daunted morale. However, the technically demanding nature of the procedure should not be underestimated