To evaluate the efficacy of Vacuum Assisted Closure (VAC) in the management of post surgical spinal sepsis. A retrospective analysis was performed of patients with severe post operative spinal wound infections treated using a combination surgical debridement, antibiotics and VAC therapy. Full records were available for a total of twenty adult all of whom had had prior thoracic or lumbar instrumentation. Comorbidities included disseminated carcinomatosis (25 % of patients), Ankylosing spondylitis (5 %), rheumatoid arthritis (5%) and Polio (5%). In one patient there had been a prior history of irradiation of the surgical field. Most infections treated by this regime were identified within two weeks following surgery. At surgery infection deep to the dorso-lumbar fascia was found in 87 % of cases. It was possible to retain instrumentation in 60 % of cases. An average of three trips to theatre were required prior to wound closure, which was possible in 95 % of cases. The VAC device was left in situ for an average of 11 days. Complications included recurrence of infection necessitating further treatment in 20 % of cases, wound dehiscence necessitating healing by secondary intention in 5%, the need for free flap wound cover in 5 % and death from unrelated causes in 5%. VAC therapy may facilitate the management of wound sepsis following spinal surgery in susceptible patients allowing the maintenance of instrumentation and surgical correction.
To determine the current practice of scoliosis surgery in the UK. A 10 point questionnaire was constructed to identify the philosophy of surgeons on various aspects of scoliosis surgery such as choice of implant, bone graft, autologous blood transfusion (ABT), cord monitoring and computer assisted surgery. Results are compared with the current best evidence. Consultants and Fellows attending the 2009 British Scoliosis Society meeting. 50 questionnaires were completed: 45 Consultants and 5 Fellows. All pedicle screw construct favored by 25/50, hybrid 24/50 (one undecided). Posterior construct of less than 10 levels, 20/50 would not cross-link, 11/50 used one and 19/20 used two or more. More than ten levels 17/50 considered cross-links unnecessary, 4/50 used one and 29/50 used two or more. 88% preferred titanium alloy implants, while a mixture of stainless steel and cobalt chrome was used by others. For bone graft, substitutes (24), iliac crest (14), allograft (12) and demineralised bone matrix (9) in addition to local bone. 10/50 would use recombinant bone morphogenetic protein (3 for revision cases only). 39/50 routinely used intra-operative cell salvage or ABT drains and 4/50 never used autologous blood. All used cord monitoring, Sensory (19/50), Motor (2/50) and combined (29/50). None used computer-aided surgery. 26 operated alone 12 operated in pairs and 12 varied depending on type of case. This survey has brought to light interesting variations in scoliosis surgery in UK. It may reflect the conflicting evidence in the literature.