Many worldwide regulatory authorities recommend regular surveillance of metal-on-metal hip arthroplasty patients given high failure rates. However concerns have been raised about whether such regular surveillance, which includes asymptomatic patients, is evidence-based and cost-effective. We determined: (1) the cost of implementing the 2015 MHRA surveillance in “at-risk” Birmingham Hip Resurfacing (BHR) patients, and (2) how many asymptomatic hips with adverse reactions to metal debris (ARMD) would have been missed if patients were not recalled. All BHR patients subject to the 2015 MHRA recall (all females, and males with head sizes 46mm or below, regardless of symptoms) at one specialist centre were invited for review (707 hips). All patients were investigated (Oxford Hip Score, radiographs, blood metal ions, and targeted cross-sectional imaging) and managed accordingly. Surveillance costs were calculated using finance department data, as was the number needed to treat (NNT) to avoid missing one case of asymptomatic ARMD.Introduction
Methods
We investigated predictors of poor outcomes following metal-on-metal hip arthroplasty (MoMHA) revision surgery performed for adverse reactions to metal debris (ARMD), to help inform the revision threshold and type of reconstruction. A retrospective cohort study was performed involving 346 MoMHAs revised for histologically confirmed ARMD at two specialist centres (245=hip resurfacing, 101=total hip arthroplasty). Numerous preoperative (blood metal ions and imaging) and intraoperative (findings, and components removed/implanted) factors were used to predict poor outcomes. Poor outcomes were postoperative complications (including re-revisions), 90-day mortality, and poor Oxford Hip Scores (<27/48). Multivariable logistic regression models for predicting poor outcomes were developed using stepwise selection methods.Introduction
Patients and Methods
We investigated whether blood metal ions could effectively identify bilateral metal-on-metal hip patients at risk of adverse reactions to metal debris (ARMD). This single-centre, prospective study involved 235 patients (185 bilateral Birmingham Hip Resurfacings (BHRs) and 50 bilateral Corail-Pinnacles) undergoing whole blood metal ion sampling (mean time=6.8 years from latest implant to sampling). Patients were divided into ARMD (revised or ARMD on imaging; n=40) and non-ARMD groups (n=195). Metal ion parameters (cobalt; chromium; maximum cobalt or chromium; cobalt-chromium ratio) were compared between groups. Optimal metal ion thresholds for identifying ARMD patients were determined using receiver operating characteristic (ROC) analysis, which compares the performance of different tests using the area under the curve (AUC) (higher AUC=more discriminatory).Introduction
Patients and methods