Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 29 - 29
1 Aug 2013
Duffy S Deep K Goudie S Freer I Deakin A Payne A
Full Access

This study measured the three bony axes usually used for femoral component rotation in total knee arthroplasty and compared the accuracy and repeatability of different measurement techniques.

Fresh cadaveric limbs (n=6) were used. Three observers (student, trainee and consultant) identified the posterior condylar (PCA), anteroposterior (AP) and the transepicondylar (TEA) axes, using a computer navigation system to record measurements. The AP axis was measured before and after being identified with an ink line. The TEA was measured by palpation of the epicondyles both before and after an incision was made in the medial and lateral gutters at the level of the epicondyles, allowing the index finger to be passed behind the gutters. In addition the true TEA was identified after dissection of all the soft tissues. Each measurement was repeated three times. For all axes and each observer the repeatability coefficient was calculated.

The identification of the PCA was the most reliable (repeatability coefficient: 1.1°) followed by the AP after drawing the ink line (4.5°) then the AP before (5.7°) and lastly the TEA (12.3°) which showed no improvement with the incisions (13.0°). In general the inter-observer variability for each axis was small (average 3.3°, range 0.4° to 6°), being best for the consultant and worst for the student. In comparison to the true TEA, the recorded TEA and AP axis averaged within 1.5° whilst the PCA was consistently 2.8° or more internally rotated.

This study echoed previous studies in demonstrating that palpating the PCA intra-operatively is highly precise but was prone to errors in representing the true TEA if there was asymmetrical condylar erosion. The TEA was highly variable irrespective of observer ability and experience. The line perpendicular line to the AP axis most closely paralleled the true TEA when measured after being identified with an ink line.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_20 | Pages 21 - 21
1 Apr 2013
Deep K Duffy S Freer I Goudie S Nalwad H Deakin A Payne A
Full Access

Introduction

Soft tissue balancing is an important aspect of total knee replacement surgery. Traditionally sequential medial soft tissue release is performed for balancing in varus deformity. Its effects on kinematics and dynamic Femoro-Tibial-Mechanical-Angle (FTMA) have been described in extension and 90° flexion in coronal plane. However most studies have missed what happens when the knee flexes from 0 to 90 degrees This study is one of the first to describe its effects on knee kinematics throughout flexion. The aim was to look at deviation of FTMA in coronal plane with traditional sequential medial release with and without measured stress applied in varus and valgus at each point of measurement through the range of flexion.

Methods

12 cadaveric knees were studied using a computer navigation system. Rigid bodies were fixed to femur and tibia. The knee was exposed as per doing TKR surgery with medial parapatellar approach with no disturbance to the collateral ligaments. The anatomy was registered using a infra red waves based passive tracker navigation system. FTMA was studied in extension, 0°, 5°, 30°,45°,60°,90° and maximum flexion. Sequential medial release was performed in 7 steps as described by Luring et al. The sequential steps were Step 1: 2 cm release (antero medial tibial sleeve), Step 2: Postero-medial release, Step 3: 4 cm medial sleeve release, Step 4: 6 cm medial sleeve release, Step 5: Deep medial collateral ligament, Step 6: posterior cruciate ligament (PCL) medial half only, Step 7: entire PCL.

At each step FTMA was measured with and without stressing at each point of flexion. A 10 Newton Meter moment arm was applied for varus and valgus stress force.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 177 - 177
1 Jan 2013
Deep K Duffy S Freer I Goudie S Nalwad H Deakin A Payne A
Full Access

Traditionally sequential medial soft tissue release is performed for balancing in total knee arthroplasty for varus knees. Its effects on kinematics have been described in extension and 90° flexion in coronal plane. This is the first study to describe its effects on kinematics throughout flexion. 12 cadaveric knees were studied using a computer navigation system to assess kinematics. Femoro-Tibial-Mechanical-Angle(FTMA) was studied in extension, 0°, 5°, 30°,45°,60°,90° and maximum flexion. Sequential medial release was performed in 7 steps, described by Luring et al(Ref). At each step FTMA was measured without and with stressing. A 10 Newton Meter moment arm was applied for varus and valgus stress. Most of the initial release steps had little effect on FTMA without force applied, especially in the initial 60° of flexion. Application of varus force demonstrated very small changes. Application of valgus force demonstrated little change in initial arc of flexion until step 5 was reached (Table 1). Our study concludes the present sequence of medial release may not be correct and should be further investigated to modify the sequence for soft tissue balancing in TKR surgery.