Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_1 | Pages 13 - 13
1 Jan 2019
Porter P Drew T Arnold G Wang W MacInnes A Nicol G
Full Access

The Pronator Quadratus (PQ) is commonly damaged in the surgical approach to the distal radius during volar plating. This study explored the functional strength of the PQ muscle, 12 months after volar plating of a distal radial fracture.

Testing of treated and contralateral forearms was carried out using a custom-made Torque Measuring Device (TMD) and surface Electromyography (sEMG). To assess both the direct and indirect function of PQ in participants treated with volar plating and compared to the contralateral non-injured forearms. The angle of elbow flexion was varied from 45o, 90o and 135o when measuring forearm pronation. Mean peak torque of the major pronating muscles, PQ and Pronator Teres (PT) was directly measured with the TMD and the indirect activation of the PQ and PT was measured with sEMG.

In total 27 participants were studied. A statistically significant reduction in mean peak pronation torque was observed in the volar plated forearms (P<0.05 SE 0.015, CI 95%). This is unlikely to be of clinical significance as the mean reduction was small (13.43Nm treated v 13.48Nm none treated). Pairwise comparison found no statistically significant reduction in peak torque between 45o, 90o and 135o of elbow flexion. There was an increase in PQ muscle activation at 135o compared to 45o elbow flexion. The converse was identified in PT.

The small but statistically significant difference in mean peak torque in treated and uninjured forearms is unlikely to be of clinical significance and results suggest adequate functional recovery of the PQ after volar plating.