Fracture-related infection (FRI) is commonly classified based on the time of onset of symptoms. Early infections (< two weeks) are treated with debridement, antibiotics, and implant retention (DAIR). For late infections (> ten weeks), guidelines recommend implant removal due to tolerant biofilms. For delayed infections (two to ten weeks), recommendations are unclear. In this study we compared infection clearance and bone healing in early and delayed FRI treated with DAIR in a rabbit model.
Aims
Methods
Propionibacterium acnes infection of the shoulder after arthroplasty is a common complication. Current detection methodologies for P. acnes involve prolonged anaerobic cultures that can take up to three weeks before findings can be reported. Our aim was to develop a polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) approach that is both sensitive and specific to P. acnes that would enable a 24-hour turnaround between biopsy and results. Comparisons between the 16S ribosomal sequences of P. acnes and closely related bacteria identified two unique regions in P.acnes to which PCR primers were designed. Additionally, two unique restriction enzyme cut sites for HaeIII were identified within this amplicon. To test the PCR method, arthroscopic surgical biopsies were mechanically homogenised and boiled for 20 minutes to lyse the cellular membranes. PCR was performed using standard conditions followed by a one hour HaeIII enzymatic digest of the PCR product. Resultant fragments were visualised on polyacrylamide gels stained with ethidium bromide. All experiments included no-template controls to rule out reagent contamination and independently confirmed P. acnes DNA as a positive control. Serial dilutions of P. acnes cultures in Robertson's cooked-meat broth and spectrophotometric analysis of cellular concentration were used to assess the sensitivity of the PCR reaction. A unique 564 base-pair PCR amplicon was derived from different strains of P. acnes. This amplicon was confirmed as P. acnes DNA by gel excision and DNA sequencing. HaeIII digests of the amplicon yielded 3 restriction fragments at the sizes predicted by in silico analyses. Sensitivity testing confirmed that as few as 10 P. acnes cells in a 50µl reaction volume could be detected using this assay. P. acnes was also detected in surgical biopsy samples. P. acnes infections following shoulder arthroplasty are a serious complication placing a burden on the healthcare system and the patient due to the lengthy surgical revision process that follows. The infections are also difficult to diagnose. This unique assay combines the sensitivity of PCR with the specificity of RFLP mapping to specifically identify P. acnes in surgical isolates. We anticipate that this assay will allow us to determine if a biopsy is P. acnes positive within 24-hours of sampling, allowing for more aggressive antibiotic therapy and monitoring to avoid implant failure and revision surgery. Additionally, this PCR-RFLP method may decrease the false positive rate of extended length cultures due to P. acnes contamination.
Between 1972 and 1990, we performed 168 primary low-friction arthroplasties in 125 patients with acetabular protrusion. Twelve hips were lost to follow-up within eight years and eight which became infected were excluded from the final study. Of the 148 hips remaining, 62 with a mild protrusion were classified as group 1, 54 with moderate or severe protrusion as group 2 and, after 1985, 32 with moderate and severe protrusion which required bone grafts as group 3. The mean follow-up was 18.3 years (3 to 24) for group 1, 17.4 years (8 to 22) for group 2 and ten years (8 to 13) for group 3. There were 31 revisions of the cup, 12 in group 1 and 19 in group 2. According to the Kaplan-Meier analysis the overall rates at 20 years were 21 ± 10.79% in group 1 and 37 ± 11.90% in group 2. There have been 43 radiological loosenings: 22 in group 1, 21 in group 2 and none so far in group 3, at ten years. The overall loosening rates at 20 years were 42 ± 14.76% in group 1 and 49 ± 19.50% in group 2. The grafts were well incorporated in all group-3 hips, and the bone structure appeared normal after one year. The distance between the centre of the head of the femoral prosthesis and the approximate true centre of the femoral head was less in group 3 than in groups 1 and 2 (p <
0.01). According to the Cox proportional-hazards regression this was the single most important factor in loosening of the cup (odds ratio 1.11; 95% CI 1.05 to 1.18/mm). Better results were obtained in moderate and severe protrusions reconstructed with bone grafting than in hips with mild protrusion which were not grafted.