The aim of this study was to analyze and compare clinical, radiological and mortality outcomes of patients who underwent cemented hip hemiarthroplasty for displaced neck of femur fractures using a SPAIRE technique when compared to a pair-matched control cohort who underwent the same procedure using the direct lateral approach. A retrospective review of patients who underwent cemented hip hemiarthroplasty for displaced neck of femur fractures by a single surgeon using a SPAIRE technique over a two-year period between July 2019 and July 2021 was performed. These were subsequently pair matched in a 5:1 ratio for age, gender, ASA grade and residential status with a control group who underwent cemented hip hemiarthroplasty by 4 other surgeons using a direct lateral approach The study included a total of 240 patients (40 and 200 pairmatched to SPAIRE and control groups respectively), with a mean age of 81.0 ± 8.2 years (63–99) and a mean follow-up of 12 ± 3 months (3–30). Overall, there was no significant difference in any of the radiological or mortality outcome scores assessed between the SPAIRE and control groups (p > 0.05 for all). There was a significantly lower number of patients in the SPAIRE group who dropped a level of mobility from their pre-injury baseline at 30-days post-operatively (8.1% versus 31.6%; p = 0.003). However, this appeared to have resolved at 120-day follow-up with no significant differences between the groups in terms of those acquiring a new baseline mobility at 120-days post-operatively (2.7% versus 13.2%, p = 0.09). In cases of cemented hip hemiarthroplasty for displaced intracapsular neck of femur fractures, the SPAIRE technique appears to offer patients an earlier return to levels of baseline pre-injury mobility when compared to a direct lateral approach.
Improvements in function after THA can be evaluated using validated health outcome surveys but studies have shown that PROMs are unreliable in following the progress of individuals. Formal gait lab analysis is expensive, time consuming and fixed in terms of location. Inertial Measurement Units (IMUs) containing accelerometers and gyroscopes can determine aspects of gait kinematics in a portable package and can be used in the outpatient setting (Figure 1). In this study multiple metrics describing gait were evaluated pre- and post THA and comparisons made with the normal population The gait of 55 patients with monarthrodial hip arthrosis was measured pre-operatively and at one year post-surgery. Patients with medical co-morbidity or other condition affecting their gait were excluded. Six IMUs aligned in the sagittal plane were attached at the level of the anterior superior iliac spines, mid-thigh and mid-shank. Data was analysed using proprietary software (Figure 2). Each patient underwent a conventional THA using a posterolateral approach. An identical test was performed one year after surgery. 92 healthy individuals with a normal observed gait were used as controls.Introduction
Methods
Post-operative gait abnormalities are recognized following total hip arthroplasty (THA). Despite global improvement in functional outcome, gait abnormality persists for a decade or more. In this study 3-dimensional gait analysis (3DGA) was performed using a portable system with Inertial Measurement Units (IMUs) to quantify this abnormality. The gait of 55 patients with monarthrodial hip arthrosis was measured pre-operatively and at one year post-surgery. Patients with medical co-morbidity or other conditions affecting their gait were excluded. Six IMUs were aligned at the level of the anterior superior iliac spines, mid-thigh and mid-leg. Data was analysed using proprietary software. Each patient underwent a conventional THA using a posterolateral approach. 92 healthy individuals were assessed for comparison.Introduction
Methods
Wound closure following orthopaedic surgery is an important step requiring careful technique and suitable suture material. The use of subcuticular sutures has been advocated following use in animal models and has also been reported in the literature having been used in specialities such as Orthopaedic Surgery, Plastic Surgery and Obstetrics. The aim of this study is to assess the use of absorbable subcuticular INSORB® sutures in THR when compared with the standard AutosutureTM SignetTM metal skin staples. Patient satisfaction with wound appearance was measured at the six week review stage. Wound healing was also noted in the initial stages of recovery and at the six week review stage.Introduction
Aims
Revision of the femoral component during revision hip arthroplasty may pose significant technical challenges, most notably femoral fracture and bone perforation. The in-cementing technique allows use of the original bone-cement interface which has been proven to be biomechanically stronger than recementing after complete removal of the original cement mantle. This study reviews a series of 54 consecutive revision hip arthroplasty procedures carried out by the senior author using the in-cementing technique from November 1999 to March 2003. Patients were followed up clinically and radiologically with serial outpatient reviews and their functional outcome was assessed using the Harris hip scoring system, the Oxford hip scoring system and the University of California at Los Angeles (UCLA) activity profile. Their physical and mental well-being was also assessed using the SF-36 self-questionnaire. Fifty-four procedures were performed on 51 patients. There were 31 males and 20 females. The average age was 70.3+/-8.1 years (range: 45-83 years). The average time to revision from the original procedure was 132.8+/-59.0 months (range: 26-286 months). The average length of follow-up was 29.2+/-13.4 months (range: 6-51 months) post revision arthroplasty. Two patients suffered dislocations, one of which was recurrent and was revised with a Girdlestone's procedure. No patient displayed any evidence of radiographical loosening. The average Harris hip score of the study group was 85.2+/-11.6 (range: 51.9-98.5). The average Oxford hip score recorded was 19.6+/-7.7 (range: 12-41) and the average UCLA activity profile score was 5.9+/-1.6 (range: 3-8). The SF-36 questionnaire had an average value of 78.0+/-18.3 (range: 31.6-100). In conclusion, the results of this study show excellent clinical and radiological results of the in-cementing technique with high patient satisfaction in terms of functional outcome. This technique merits consideration where possible in revision hip arthroplasty.
The in-cement technique for revision hip arthroplasty involves retaining the original cement-bone interface. This has been proven to be a biomechanically stronger method than recementing after complete removal of the original cement mantle. This study reviewed a series of 54 consecutive revision hip arthroplasty procedures, using the in-cement technique, between November 1999 and November 2003. Clinical and radiological follow-up included functional assessment. There were 54 procedures performed in 51 patients, whose mean age at surgery was 70.3 years (45 to 85). A total of 42 were available at a mean follow-up of 29.2 months (6 to 51). There was no radiological evidence of loosening. Functional assessments were available for 40 patients who had a mean Harris hip score of 85.2 (51.9 to 98.5), a mean Oxford hip score of 19.6 (12 to 41), a mean UCLA activity profile score of 5.9 (3 to 8) and a mean SF-36 score of 78.0 (31.6 to 100). The in-cement technique provides consistent, high functional outcomes and should be considered in appropriately selected cases.
Revision of the femoral component during revision hip arthroplasty may pose significant technical challenges, most notably femoral fracture and bone perforation. The in-cementing technique allows use of the original bone-cement interface that has been proven to be biomechanically stronger than recementing after complete removal of the original cement mantle. This historical prospective study reviews a series of 54 consecutive revision hip arthroplasty procedures carried out by the senior author using the in-cementing technique from November 1999 to March 2003. Patients were followed up clinically and radiologically with serial outpatient reviews and their functional outcome was assessed using the Harris hip scoring system, the Oxford hip scoring system and the University of California at Los Angeles (UCLA) activity profile. Their physical and mental well being was also assessed using the SF-36 self-questionnaire. Fifty-four procedures were performed on 51 patients. There were 31 males and 20 females. The average age was 70.3+/−8.1 years (range: 45 – 83 years). The average time to revision from the original procedure was 132.8+/−59.0 months (range: 26 – 286 months). The average length of follow up was 29.2+/−13.4 months (range: 6 – 51 months) post revision arthroplasty. Two patients suffered dislocations, one of which was recurrent and was revised with a Girdlestone’s procedure. No patient displayed any evidence of radiographical loosening. The average Harris hip score of the study group was 85.2+/−11.6 (range: 51.9 – 98.5). The average Oxford hip score recorded was 19.6+/−7.7 (range: 12 – 41) and the average UCLA activity profile score was 5.9+/−1.6 (range: 3 – 8). The SF-36 questionnaire had an average value of 78.0+/−18.3 (range: 31.6 – 100) with an average physical score of 73.3+/−22.2 (range: 20.5 – 100). In conclusion, we feel the results of this study show excellent clinical and radiological results of the in-cementing technique with high patient satisfaction in terms of functional outcome. This technique merits consideration where possible in revision hip arthroplasty.