Introduction

Controversy exists as to whether the short external rotator tendons and capsule of the hip should be repaired after posterior approach primary total hip arthroplasty (THA). Recent studies using radiopaque markers have demonstrated that reimplantation of these muscle tendons fail early and may not prevent post operative dislocation.

Methods

Using dynamic ultrasound examination we evaluated the patency of repair in 68 tendon groups (piriformis/conjoint tendon and obturator externus). We demonstrate short and medium term success in the reimplantation of these tendons using the double transosseous drill hole technique of reattaching the tendons and capsule to the greater trochanter. We followed up 21 of our total hip replacements and 13 hip resurfacings and undertook a dynamic ultrasound examination of the external rotators by an experienced musculoskeletal radiologist to assess their integrity at a minimum of 60 days and 100 days and an average of 213 days after the operation.