header advert
Results 1 - 3 of 3
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 103 - 103
1 Apr 2019
Westrich GH Swanson K Cruz A Kelly C Levine A
Full Access

INTRODUCTION

Combining novel diverse population-based software with a clinically-demonstrated implant design is redefining total hip arthroplasty. This contemporary stem design utilized a large patient database of high-resolution CT bone scans in order to determine the appropriate femoral head centers and neck lengths to assist in the recreation of natural head offset, designed to restore biomechanics. There are limited studies evaluating how radiographic software utilizing reference template bone can reconstruct patient composition in a model. The purpose of this study was to examine whether the application of a modern analytics system utilizing 3D modeling technology in the development of a primary stem was successful in restoring patient biomechanics, specifically with regards to femoral offset (FO) and leg length discrepancy (LLD).

METHODS

Two hundred fifty six patients in a non-randomized, post-market multicenter study across 7 sites received a primary cementless fit and fill stem. Full anteroposterior pelvis and Lauenstein cross-table lateral x-rays were collected preoperatively and at 6-weeks postoperative. Radiographic parameters including contralateral and operative FO and LLD were measured. Preoperative and postoperative FO and LLD of the operative hip were compared to the normal, native hip. Clinical outcomes including the Harris Hip Score (HHS), Lower Extremity Activity Scale (LEAS), Short Form 12 (SF12), and EuroQol 5D Score (EQ-5D) were collected preoperatively, 6 weeks postoperatively, and at 1 year.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 131 - 131
1 Feb 2017
Garcia-Rey E Cimbrelo EG Cruz-Pardos A
Full Access

Background and aim

A significant reduction in wear using Durasul highly cross-linked polyethylene (PE) versus Sulene polyethylene (sterilized with nitrogen) at 5 and 10 years have been reported previously. We ask if the improvement observed at the earlier follow-up continues at 15 years.

Methods

Between 1999 and 2001, 90 hips underwent surgery using the same cementless cup and stem: 45 received Allofit cups with a Sulene-PE liner and 45 Allofit cups with a Durasul-PE liner, both associated with an Alloclassic stem (28 mm metallic femoral head). 66 hips of this prospective comparative study were available over a minimum follow-up of 15 years. Linear femoral head penetration was estimated digitally at 6 weeks, at 6 and 12 months and annually thereafter, using the Dorr method, given the nonspherical cup shape. All radiographs were evaluated by the same author, who was not involved in surgery.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 85 - 85
1 Feb 2017
Cruz A Perona P Cohen R Campbell D
Full Access

Background

Instability and dislocation are some of the most important postoperative complications and potential causes of failure that dual mobility total hip arthroplasty (THA) systems continue to address. Studies have shown that increasing the relative head size provides patients implanted with smaller and larger cups increased stability, greater ROM and a lesser incidence of impingement, without compromising clinical results. The purpose of the current study was to review clinical outcomes in three groups of primary THA patients receiving a dual mobility acetabular shell.

Methods

In two US based, post-market, multicenter studies, 450 patients received a primary cementless dual mobility THA. Patients were split into three groups based on cup size: ≤ 50mm, 52mm–56mm, and ≥ 58mm. Harris Hip Scores (HHS), Short Form 12 Physical Components (SF12 PCS), Lower Extremity Activity Scores (LEAS), and Euroqol 5D Score (EQ-5Ds) were collected preoperatively and through 2 years postoperative.