286 patients underwent total hip arthroplasty with a cemented titanium femoral implant (Ultima, Johnson & Johnson) between July 1995 and July 2001. The acetabular component was either a porous coated cup or a cemented all-polyethylene cup. A 28mm cobalt chromium head was used in all patients. Patients were prospectively evaluated with clinical examination, Harris hip scores and radiographic assessment. Analysis of the data was performed. Of the 286 patients, 11 patients were excluded from analysis for reasons including incomplete data (8) and death (3). The remaining 275 patients were comprised of 118 males and 157 females with an average age of 70.8 years (55–89 years). The average follow up was 10.5 years (1.03–14.23). The median follow up was 10 years. 177 cemented all-polyethylene and 98 porous coated acetabular cups were used. The average Harris hip scores were 34.4 and 81.25 for preoperative and last follow up visit respectively. 11 stems were revised (aseptic loosening 9, infection 2). Radiographic assessment showed vertical subsidence in 30 patients (10.9%) (>5mm in 6 and < 5mm in 24 patients). Complete cement-bone radiolucency was noted in 11 stems (4%). Radiolucent lines covering < 50% of cement-bone interface were noted in 18 stems (6.5%). There were no cases of cement fracture. Kaplan-Meier survivorship was 91% at 10 years & 89.8% at 12 years.Method
Results
Previous studies comparing cruciate retaining (CR) and cruciate sacrificing - posterior stabilised (PS) TKRs have failed to demonstrate a difference in outcomes based on numbers of patients recruited. This large study compares clinical outcomes in groups having PS and CR TKR and reports the results at 1 and 2 years post-operatively. A total of 683 patients undergoing TKR were consecutively enrolled in a prospective multi-centre study with 2 arms. In the first arm patients receiving a PS component were randomised to receive either a mobile bearing (176 patients) or fixed bearing (176 patients) implant. In the second arm, patients receiving a CR component were randomised to receive either a mobile bearing (161 patients) or fixed bearing (170 patients) implant. All patients were assessed preoperatively and at one and two years postoperatively using standard tools (Oxford, AKSS, Patellar Score) by independent nurse specialists. The data from the 2 arms of the trial were then analysed to compare differences between PS and CR implants.Introduction
Methods
It is hypothesised that cruciate retention in total knee arthroplasty may result in improved kinematics of the knee by maintaining the femoral rollback seen in the normal knee, resulting in improved function. This study compares clinical outcomes in groups having PS and CR total knee arthroplasty and report the results at 1 and 2 years post-operatively.
Patients with a PS also showed a greater improvement in the AKSS knee score at 1 (p=0.0001) and 2 (p=0.001) years. Knee flexion improvement was also greater in the PS group at 1 (p=0<
0.0001) and 2 (p=0.0035) years. PS knees also achieved better outcomes in these variables in the mobile and fixed subgroups. There were no other significant differences in the scores between the two groups at any stage.
Ten epiphyses in seven children underwent fixed-rate distraction of 0.25 mm twice daily in an attempt to achieve percutaneous leg lengthening by chondrodiatasis. The forces generated across the growth plate were recorded by means of strain gauges incorporated into the distractors. All epiphyses fractured before 33 days of lengthening. An average gain of 6.75 cm was achieved. Epiphyseal distraction at the lower femur produced many complications, but at the upper tibial epiphysis planned lengthening was achieved, with excellent bone production and few complications.
It has been shown that raised intracapsular pressure causes avascular necrosis of the femoral head in experimental animals, but the relevance of this to clinical fractures of the femoral neck is controversial. We have studied 19 patients with intracapsular fractures of the femoral neck by pressure measurement and by ultrasonography to demonstrate capsular distension. The intra-articular pressure in Garden Grade I and II fractures averaged 66.4 mmHg with a maximum of 145 mmHg. In 10 Garden Grade III and IV fractures the average pressure was 28 mmHg with a maximum of 65 mmHg. Most of the recorded intracapsular pressures were high enough to have caused possible vascular embarrassment, and it is suggested that early decompression of the haemarthrosis should be considered.
Five patients known to be HIV (human immunodeficiency virus)-positive--that is, susceptible to AIDS--presented with symptoms initially thought to be indicative of lumbar disc lesions. Signs of nerve root or cauda equina compression were found in all five patients. Lumbar radiculography and, in one patient, computerised tomography produced no evidence of compressive pathology. We recommend that orthopaedic surgeons exercise caution in diagnosing nerve root compression in patients who may be HIV-positive.