header advert
Results 1 - 2 of 2
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 315 - 315
1 May 2006
Mohammed K Broksbank A Gooding A Coates M
Full Access

The aim was to define the operative and MRI arthrogram findings in recurrent post stabilization instability, to establish the accuracy of MRI findings compared to surgical findings, and to define the role of MRI in evaluation and planning for these patients.

The operative findings in 25 consecutive patients undergoing revision shoulder stabilization procedures were reviewed. 18 of these patients had MRI arthrograms prior to their revision procedure. All revision procedures were performed by the same surgeon, and all MRI scans reviewed by 2 musculoskeletal radiologists.

Primary and contributing factors for instability were identified for each patient. Primary factors for failure included; new injury at a different site to the index repair (6 patients), laxity of the inferior glenohumeral ligament (5 patients), failure of the index repair (7 patients) and failure to address the pathology at the index procedure (7 patients).

MRI arthrography had 85% sensitivity, 100% specificity and 89% accuracy.

MRI arthrography is accurate in assessment of the labrum in recurrent post stabilization instability. Recurrent instability is complex and multifactorial, but a primary factor can often be identified. In some cases new trauma results in injury at a different site to the initial repair. MRI arthrogram may assist in surgical planning. If a labral injury is present without laxity or a glenoid bony defect, arthroscopic revision may be undertaken. If significant capsular laxity or bone deficiency is present, then an open procedure with capsular shift and rotator interval closure may be appropriate.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 21 - 22
1 Mar 2005
Talbot S Hooper G Inglis G Coates M
Full Access

Our aim was to assess the clinical and radiological medium-term outcome of a series of 153 consecutive total hip arthroplasties performed by two surgeons in Christchurch using the ABG hydroxyapatite-coated femoral stem and Duraloc 100-series uncemented acetabulum.

An independent clinical review using interviews and patient notes and radiological review of immediate postoperative and most recent x-rays was carried out.

At six to eleven years with approximately 95% follow-up, there were no stem failures, but two revisions following a fracture from significant trauma. Two cups were revised for loosening and one cup bone grafted for osteolysis. A dislocation occurred in 4.7% of cases requiring two liner exchanges and one cup revision. A low incidence of thigh pain and excellent radiographic results of the stem with high rates of bony ingrowth and no incidence of significant loosening was a feature of this series.

We report excellent results at medium-term follow up for an unceme4nted HA- coated femoral stem.