Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 42 - 49
1 Jan 2018
Walker T Zahn N Bruckner T Streit MR Mohr G Aldinger PR Clarius M Gotterbarm T

Aims

The aim of this independent multicentre study was to assess the mid-term results of mobile bearing unicondylar knee arthroplasty (UKA) for isolated lateral osteoarthritis of the knee joint.

Patients and Methods

We retrospectively evaluated 363 consecutive, lateral UKAs (346 patients) performed using the Oxford domed lateral prosthesis undertaken in three high-volume knee arthroplasty centres between 2006 and 2014. Mean age of the patients at surgery was 65 years (36 to 88) with a mean final follow-up of 37 months (12 to 93)


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 45 - 45
1 Mar 2013
Seeger J Haas D Jäger S Clarius M
Full Access

Introduction

Periprosthetic medial tibial plateau fractures (TPF) are rare but represent a serious complication in unicompartmental knee arthroplasty (UKA). Most common treatment of these fractures is osteosynthesis with canulated screws or plates.

Aim

The aim of this study was to evaluate these two different treatment options of periprosthetic fractures. The hypothesis was that osteosynthetic treatment with plates show significantly higher maximum fracture loads than fixation with cannulated screws.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1356 - 1361
1 Oct 2012
Streit MR Walker T Bruckner T Merle C Kretzer JP Clarius M Aldinger PR Gotterbarm T

The Oxford mobile-bearing unicompartmental knee replacement (UKR) is an effective and safe treatment for osteoarthritis of the medial compartment. The results in the lateral compartment have been disappointing due to a high early rate of dislocation of the bearing. A series using a newly designed domed tibial component is reported.

The first 50 consecutive domed lateral Oxford UKRs in 50 patients with a mean follow-up of three years (2.0 to 4.3) were included. Clinical scores were obtained prospectively and Kaplan-Meier survival analysis was performed for different endpoints. Radiological variables related to the position and alignment of the components were measured.

One patient died and none was lost to follow-up. The cumulative incidence of dislocation was 6.2% (95% confidence interval (CI) 2.0 to 17.9) at three years. Survival using revision for any reason and aseptic revision was 94% (95% CI 82 to 98) and 96% (95% CI 85 to 99) at three years, respectively. Outcome scores, visual analogue scale for pain and maximum knee flexion showed a significant improvement (p < 0.001). The mean Oxford knee score was 43 (sd 5.3), the mean Objective American Knee Society score was 91 (sd 13.9) and the mean Functional American Knee Society score was 90 (sd 17.5). The mean maximum flexion was 127° (90° to 145°). Significant elevation of the lateral joint line as measured by the proximal tibial varus angle (p = 0.04) was evident in the dislocation group when compared with the non-dislocation group.

Clinical results are excellent and short-term survival has improved when compared with earlier series. The risk of dislocation remains higher using a mobile-bearing UKR in the lateral compartment when compared with the medial compartment. Patients should be informed about this complication. To avoid dislocations, care must be taken not to elevate the lateral joint line.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 131 - 131
1 May 2011
Seeger J Haas D Aldinger P Jaeger S Bruckner T Clarius M
Full Access

Periprosthetic tibial plateau fractures (PTPF) represent a rare but serious complication in unicompartmental knee arthroplasty (UKA). Although excellent long-term results have been reported with cemented UKA, surgeons continue to be interested in cementless fixation. The aim of the study was to compare fracture loads of cementless and cemented UKA.

Tibial components of the Oxford UKA were implanted in six paired fresh-frozen tibiae. In one set surgery was performed with cement fixation and in the other cementless components were implanted. Loads were then applied under standardised conditions to fracture the specimens.

Mean loads of 3.6 (0.7–6.9) kN led to fractures in the cemented group, whereas the tibiae fractured in the cementless group with a mean load of 1.9 (0.2–4.3) kN (p< 0.05).

The loading capacity in tibiae with cementless components is significantly less compared to cemented fixation. Our results suggest that, patients with poor bone quality who are treated with a cementless UKA are at higher risk for periprosthetic fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 178 - 183
1 Feb 2011
Streit MR Merle C Clarius M Aldinger PR

Peri-prosthetic femoral fracture after total hip replacement (THR) is associated with a poor outcome and high mortality. However, little is known about its long-term incidence after uncemented THR.

We retrospectively reviewed a consecutive series of 326 patients (354 hips) who had received a CLS Spotorno replacement with an uncemented, straight, collarless tapered titanium stem between January 1985 and December 1989. The mean follow-up was 17 years (15 to 20). The occurrence of peri-prosthetic femoral fracture during follow-up was noted. Kaplan-Meier survival analysis was used to estimate the cumulative incidence of fracture.

At the last follow-up, 86 patients (89 hips) had died and eight patients (eight hips) had been lost to follow-up. A total of 14 fractures in 14 patients had occurred. In ten hips, the femoral component had to be revised and in four the fracture was treated by open reduction and internal fixation. The cumulative incidence of peri-prosthetic femoral fracture was 1.6% (95% confidence interval 0.7 to 3.8) at ten years and 4.5% (95% confidence interval 2.6 to 8.0) at 17 years after the primary THR. There was no association between the occurrence of fracture and gender or age at the time of the primary replacement.

Our findings indicate that peri-prosthetic femoral fracture is a significant mode of failure in the long term after the insertion of an uncemented CLS Spotorno stem. Revision rates for this fracture rise in the second decade. Further research is required to investigate the risk factors involved in the occurrence of late peri-prosthetic femoral fracture after the implantation of any uncemented stem, and to assess possible methods of prevention.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 620 - 620
1 Oct 2010
Seeger J Aldinger P Bruckner T Clarius M Haas D Jäger S
Full Access

Background and Purpose: Periprosthetic tibial plateau fractures are a rare but serious complication of UKA. Since they usually appear perioperatively they can be associated with sawing defects during implantation. The aim of the study was to evaluate fracture loads and fracture patterns under particular consideration whether extended vertical saw cuts reduce the stability of the tibial plateau and increase the risk of periprosthetic tibial plateau fractures.

Material and Methods: In 6 matched paired fresh frozen tibiae (donor data: f/m = 2/4, mean age 81.2 years, mean weight 61.7kg) tibial implantation of the cemented Oxford Uni was performed in group A and with an extended vertical saw cut of 10° in group B in a randomized fashion. Before fracturing the tibiae with a maximum load of 10.0kN under standard conditions, DEXA bone density measurement and standard X-Ray were accomplished. After load induction fracture patterns and maximum fracture loads were analyzed and correlated to BMD, BMI, bodyweight (BW), age and surface area of the tibial implant.

Results: In group A a maximum load of Fmax = 3.912 (2.346–8.500) kN lead to fractures, whereas in group B all tibiae fractured with a mean load of Fmax = 2.622 (1.085–5.036) kN. The difference was statistically different with p=0.028. The induced fractures were similar to those observed in clinical practice.

Between BMI and the maximum fracture loads inducing tibial plateau fractures a significant correlation could be proven for all tibiae (r=0.643).

Discussion: The observed fracture pattern showed metaphyseal fractures similar to those observed in clinical practise. Extended vertical saw cuts weaken the bone structure and therefore raise the risk of medial tibial plateau fractures. In our study extended vertical saw cuts of 10° reduce maximum fracture loads about 30%.

We recommend special training and modified instruments for inexperienced surgeons to minimize the incidence of extended vertical saw cuts and to reduce the risk of periprosthetic fractures.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 317 - 318
1 May 2010
Bitsch R Jäger S Mohr G Lürssen M Seeger J Clarius M
Full Access

Introduction: The medial unicompartmental knee prosthesis (UKA) is less invasive than total knee arthroplasty (TKA) and preserves undamaged structures of the joint. The range of movement and recovery are better in UKA, while postoperative pain reduction is at least equal to TKA. UKA have a higher revision rate than TKA (15% vs 10% after 10 years). One main reason for revision is mechanical loosening1. There is a paucity of information regarding cement fixation of UKA. We compared jet lavage to conventional lavage with focus on cement pressures, interface temperatures and cement penetration.

Materials and Methods: UKA was performed in 10 paired entire human cadaver legs (Oxford Phase III, Biomet, Dordrecht, NL). Customized tibial implants and a pressure probe insert were used to measure the cement pressure anterior, posterior and near the implant fin during implantation and polymerisation. A drilling and fixation jig was used for standardized positioning of the three temperature probes. The polymerization heat was measured 5 mm below the bone surface at the medial and lateral plateau as well as under the fin. The same cementing technique was performed for all knees using Refobacin® Bone Cement R. One side of the paired knees was cleaned using jet lavage, contra lateral cleaning was done with conventional lavage. The lavage volume was equal for both

Methods: AP radiographs were taken and digitalized to quantify the cement penetration areas and depths, using a pixel-analysis-software. Group comparisons were done with the Wilcoxon-Test using SPSS (SPSS Inc., Chicago, Illinois).

Results: Average cement pressure under the tibial implant is significantly higher for conventional lavage (avg cement pressure 25.69 ± 17.85 kPa, p= 0.005) than for jet lavage (avg cement pressure 13.28 ± 12.82 kPa). Mean temperature increase measured 5 mm below the bone surface medial and lateral, as well as under the implant fin, were statistically significant higher for the cementing technique with jet lavage (lat. 14.10 ± 5.72°C, p= 0.018/med. 8.49 ± 4.20°C, p= 0.176/fin 5.95 ± 1.92°C, p= 0.063) than for the conventional lavage (lat. 9.42 ± 5.17°C/med. 6.42 ± 2.21°C/fin 3.96 ± 2.03°C). On AP radiographs, cement penetration areas under the tibial implant were significantly higher for jet lavage (penetration area: 122.15 ± 33.94 sq mm, p= 0.046) than for conventional lavage (penetration area: 89.82 ± 23.92 sq mm).

Discussion: The use of jet lavage showed clear advantages in our cadaver studies. Jet lavage resulted in higher cement penetration despite of lower cement pressures under the tibial implant. The higher cement penetration lead to higher interface temperatures but exposure to high temperatures over 50 °C with a risk for bone necrosis could not be measured.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 47 - 47
1 Mar 2009
Aldinger P Hauck C Clarius M
Full Access

Radiolucent lines (RL) are a common radiographic finding following Oxford Uni knee arthroplastv. These RL are commonly seen at the bone-cement interface under the tibial tray and can only be evaluated using screened radiographs. These lines occur during the first year, are well defined and remain constant for years. The clinical relevance of this phenomenon is unclear. Pulse lavage has the potential to thoroughly clean the trabecular bone by clearing the bone from bone marrow and debris and can thereby facilitate cement penetration and interdigitation into trabecular bone.

Pulse lavage can reduce the occurrence of radiolucent lines under the tibial tray by improving cement penetration and interdigitation.

Since 2001 we routinely use pulse lavage before cementing the Oxford uni implants at the Orthopä-dische Universitätsklinik Heidelberg (group A). At Nuffield Orthopeadic Center, Oxford conventional irrigation has been used before cementing (group B). At a minimum follow-up of 1 year 56 screened AP radiographs of the knee after Oxford UCA have been blinded and evaluated for radiolucency and cement penetration by an independent observer. For standardized evaluation the cement bone interface has been devided into 4 zones and a specific algorithm for evaluation of the radiographs has been developed.

Complete radiolucencies were detected in 2 cases (4%) in group A and in 13 cases (23%) in group B (p=0,001). Partial radiolucent lines were seen in 32 knees of group A (57%) and in 40 knees (71%) in group B. In zone 1 RLs were found in 31 tibias (55%) in group A, in 32 tibias (57%) in group B. In zone 2 17 (30%) group A, 29 (52%) group B. In Zone 3 4 (7%) in Gruppe A, 20 (36%) in group B. In Zone 4 6 (11%) group A, 30 (54%) group B. The differences between group A and B were significant (P=0.001) in zones 2, 3 and 4.

In group A in 14 cases (25%) RL were limited to one zone, in group B in 5 cases (9%), respectively. In 12 cases (21%) 2 zones were affected in group A (12 cases (21%) group B). RLs in 3 zones were found in 4 cases (7%) in group A and in 10 cases (18%) in group B.

Mean cement penetration (mm) was 2,3mm in group A and in 1,4mm in group B. The use of pulsed lavage led to an increase in cement penetration by a factor of 1,6 (cement penetration in group A/B zone 1: 1,4mm/0,8mm; zone 2: 2,4mm/1,5mm; zone 3: 1,4mm/0,7mm; zone 4: 4,0mm/2,4mm).

The use of pulsed lavage significantly decreases the appearance of RLs at a minimum of 1 year follow-up by increasing cement penetration into cancellous bone. Even though the clinical relevance of tibial RLs in unclear we recommend the use of pulse lavage to improve cement penetration and interdigitation with cancellous bone. Unnecessary revisions due to misinterpretation of RLs may be prevented.