Literature has argued for the ‘surgical personality’. Characteristics of ‘successful’ orthopaedic surgeons have also been published. The aim of the study is to explore which factors influence career choice of trauma and orthopaedics (T&O) in medical students, and whether certain personalities are drawn to T&O. The survey was sent out by email to surgical society members by the surgical societies based in Cardiff, UK. The survey was completed by students interested in pursuing T&O. The survey required participants to complete the 16 personalities test. The survey explored which factors drew delegates to T&O.Aim
Methods
Use of videos for patient education has grown in popularity. Literature promotes the use of videos to provide clearer information to patients and families. Information to patients are often provided via leaflets. In our regional (Cwm Taf Morgannwg University Health board- CTM UHB) one stop clinic, we aimed to pilot the use of an educational video on developmental dysplasia of the hip (DDH) for parents and guardians and assess its usefulness. Parents and guardians of children being treated for DDH with Pavlick harness were invited to the partake in the pilot scheme. A short video provided by the ‘What? Why? Children in Hospital’ (WWCIH) organisation was shown on a tablet to parents and guardians. A ten question questionnaire was then provided post watching the video. The questionnaire consisted of short answer, multiple choice, and rating scale (1-10) questions.Aims
Methods
The purpose of this study was to elucidate kinematic change according to the implant's specific femoral rotation by using orthosensor (Verasense) implant with three degrees external rotation of femoral rotation rebuilt (Genesis-II) and traditional TKA implant without rebuilt of the femoral rotation (Anthem). Twenty-eight patients (34 knees) underwent TKA using Anthem (Smith & Nephew, Memphis, TN, USA) and 16 patients (22 knees) underwent TKA using Genesis-II (Smith & Nephew, Memphis, TN, USA). Patients were followed up for at least 1 year. Mean age of patients was 71.1 years (range, 60 to 80 years) at the time of surgery. After implantation of femur and tibial components, we applied Verasense, the orthosensor system, to evaluate femoral rollback of the new artificial joint. Femoral rollback was analyzed using digitized screenshot function of Verasense.Purpose
Methods
The role of unicompartmental knee arthroplasty (UKA) in spontaneous osteonecrosis of the knee (SONK) remains controversial, even though SONK usually involves only medial compartment of the knee joint. We aimed to compare the survival rate and clinical outcomes of UKA in SONK and medial compartment osteoarthritis (MOA) via a meta-analysis of previous studies. MEDLINE database in PubMed, the Embase database, and the Cochrane Library were searched up to January 2018 with keywords related to SONK and UKA. Studies were selected with predetermined inclusion criteria: (1) medial UKA as the primary procedure, (2) reporting implant survival or clinical outcomes of osteonecrosis and osteoarthritis, and (3) follow-up period greater than 1 year. Quality assessment was performed using the risk of bias assessment tool for non-randomised studies (RoBANs). A random effects model was used to estimate the pooled relative risk (RR) and standardised mean difference. The incidence of UKA revision for any reason was significantly higher in SONK than in MOA group (pooled RR = 1.83, p = 0.009). However, the risk of revision due to aseptic loosening and all- cause re-operation was not significantly different between the groups. Moreover, when stratified by the study quality, high quality studies showed similar risk of overall revision in SONK and MOA (p = 0.71). Subgroup analysis revealed worse survival of SONK, mainly related to high failure after uncemented UKA. Clinical outcomes after UKA were similar between SONK and MOA (p = 0.66). Cemented UKA has similar survival and clinical outcomes in SONK and MOA. Prospective studies designed specifically to compare the UKA outcomes in SONK and MOA are necessary.
Occasionally, patients experience new or increased ankle pain following total knee arthroplasty (TKA). The aims of this study were to determine (1) how the correction of varus malalignment of the lower limb following TKA affected changes in alignment of the ankle and hindfoot, (2) the difference in changes in alignment of the ankle and hindfoot between patients with and without ankle osteoarthritis (OA), and (3) whether the rate of ankle pain and the clinical outcome following TKA differed between the 2 groups. We retrospectively reviewed prospectively collected data of 56 patients (99 knees) treated with TKA. Among these cases, concomitant ankle OA was found in 24 ankles. Radiographic parameters of lower-limb, ankle, and hindfoot alignment were measured preoperatively and 2 years postoperatively. In addition, ankle pain and clinical outcome 2 years after TKA were compared between patients with and without ankle OA.Background
Methods
Authors sought to determine the degree of lateral condylar hypoplasia of distal femur was related to degree of valgus malalignment of lower extremity in patients who underwent TKA. Authors also examined the relationships between degree of valgus malalignment and degree of femoral anteversion or tibial torsion. This retrospective study included 211 patients (422 lower extremities). Alignment of lower extremity was determined using mechanical tibiofemoral angle (mTFA) measured from standing full-limb AP radiography. mTFA was described positive value when it was valgus. Patients were divided into three groups by mTFA; more than 3 degrees of valgus (valgus group, n = 31), between 3 degrees of valgus to 3 degrees of varus (neutral group, n = 78), and more than 3 degrees of varus (varus group, n = 313). Condylar twisting angle (CTA) was used to measure degree of the lateral femoral condylar hypoplasia. CTA was defined as the angle between clinical transepicondylar axis (TEA) and posterior condylar axis (PCA). Femoral anteversion was measured by two methods. One was the angle formed between the line intersecting femoral neck and the PCA (pFeAV). The other was the angle formed between the line intersecting femoral neck and clinical TEA (tFeAV). Tibial torsion was defined as a degree of torsion of distal tibia relative to proximal tibia. It was determined by the angle formed between the line connecting posterior cortices of proximal tibial condyles and the line connecting the most prominent points of lateral and medial malleolus. Positive values represented relative external rotation. Negative values represented relative internal rotation.Background
Methods
Recently, concerns arose over the medial tibial bone resorption of a novel cobalt-chromium (CoCr) implant. This study aimed to investigate the effects of tibial component material, design, and patient factors on periprosthetic bone resorption and to determine its association with clinical outcomes after total knee arthroplasty (TKA). A total of 462 primary TKAs using five types of implants were included. To evaluate tibial periprosthetic bone resorption, we assessed radiolucent lines (RLL) and change in bone mineral density at the medial tibial condyle (BMDMT). Factors related to bone resorption were assessed using regression analysis. Clinical outcomes were also evaluated with respect to periprosthetic bone resorption. Compared to titanium (Ti) implants, CoCr implants showed a higher incidence of complete RLL (23.1% vs. 7.9% at two years post-TKA) and a greater degree of BMDMT reduction. However, there was no significant difference between the implants made of the same material. Increased medial tibial bone resorption was associated with male sex, osteoporosis, larger preoperative varus deformity, longer follow-up period, and lower body mass index. The periprosthetic bone resorption was not associated with clinical outcomes including changes in range of motion and WOMAC score. Furthermore, no cases warranted additional surgery. Periprosthetic bone resorption was associated with implant material but not with implant design. Moreover, patient factors were related to the medial tibial bone resorption post-TKA. However, the periprosthetic bone resorption was not associated with short-term clinical outcomes. We contend that researchers should incorporate integrative considerations when developing and assessing novel implants.
We sought to determine whether there was a difference in the posterior condylar offset (PCO), posterior condylar offset ratio (PCOR) following total knee arthroplasty (TKA) with anterior referencing (AR) or posterior referencing (PR) systems. We also assessed whether the PCO and PCOR changes, as well as patient factors were related to range of motion (ROM) in each referencing system. In addition, we examined whether the improvements in clinical outcomes differed between the two referencing systems. This retrospective study included 130 consecutive patients (184 knees) with osteoarthritis who underwent primary posterior cruciate ligament (PCL)-substituting fixed-bearing TKA. All patients were categorized into the AR or PR group according to the referencing system used. Radiographic parameters, including PCO and PCOR, were measured using true lateral radiographs. The difference between preoperative and postoperative PCO and PCOR values were calculated. Clinical outcomes including ROM and Western Ontario and McMaster University (WOMAC) scores were evaluated preoperatively and at 2 years after TKA. The PCO, PCOR values, and clinical outcomes were compared between the two groups. Furthermore, multiple linear regression analysis was performed to determine the factors related to postoperative ROM in each referencing system.Purpose
Methods
This paper aims to analyze the kinetics of the over-ground wheel-type body weight supporting system (BWS); tendency changes of low extremity joint moment (hip, knee, ankle), 3 axis accelerations of a trunk, cadence and gait velocity as weight bearing level changes. 15 subjects (11 males, 4 females, age:23.63.5, height:170.65.1cm, weight:69.0210.75kg) who had no history of surgery participated. 6 levels (0%, 10%, 20%, 30%, 40% and 50%) of BWS were given to subjects at self-selected gait velocity and kinetic data was calculated using a motion capture system, Vicon® (Vicon, UK).Objective
Method
Management and outcomes of fungal periprosthetic joint infection (PJI) remain unclear due to its rarity. Although two-stage exchange arthroplasty is considered a treatment of choice for its chronic features, there is no consensus for local use of antifungal agent at the 1st stage surgery. The purpose of this study was to evaluate the efficacy of antifungal-impregnated cement spacer in two-stage exchange arthroplasty against chronic fungal PJIs after total knee arthroplasty (TKA). Nine patients who were diagnosed and treated for chronic fungal PJIs after TKA in a single center from January 2001 to December 2016 were enrolled. Two-stage exchange arthroplasty was performed. During the 1st stage resection arthroplasty, amphotericin-impregnated cement spacer was inserted for all patients. Systemic antifungal medication was used during the interval between two stage operations. Patients were followed up for more than 2 years after exchange arthroplasty and their medical records were reviewed.Purpose
Methods
Joint arthroplasties may be associated with a blood loss, which necessitates transfusion. Especially, hip arthroplasties are highly associate with transfusion to compensate perioperative bleeding. Orthopaedic surgeons and patients have increasing concerns regarding complications of blood transfusions. Although various methods to reduce transfusions have been attempted in TJA, a high percentage of patients require a transfusion during and after the procedures. The purposes of this study were to evaluate the trends of the transfusion(transfusion rates, transfusion amounts, economic burden) in hip arthroplasties, using nationwide data from the National Health Insurance Service (NHIS). We used data from nationwide claims database of Health Insurance Review Assessment Service (HIRA). The data managed by the NHIS were used to identify the 161,934 hip arthroplasties by 3 categories including bipolar hemiarthroplasty(BH), total hip arthroplasty(THA), and revision arthroplasty(RA) from 2007 to 2015. These 3 categories were classified using the operation code recorded in the requisition data of NHIS. The transfusion rates, transfusion amounts, proportion of transfusion, cost of each type of operation was investigated and stratified by age, gender, hospital type, and area in hip arthroplasties. The proportion of transfusion about whole blood, red blood cell, fresh frozen plasma, platelet, was also evaluated in hip arthroplasties.Aims
Patients and methods
Patellofemoral complications have dwindled with contemporary total knee designs that market anatomic trochlear grooves that intend to preserve normal patella kinematics. While most reports of patellofemoral complications address patella and its replacement approach, they do not focus on shape of trochlear grooves in different prostheses [1]. The purpose of this study was to characterize 3D geometry of trochlear grooves of contemporary total knee designs (NexGen, Genesis II, Logic, and Attune) defined in terms of sulcus angle and medial-lateral offset with respect to midline of femoral component in coronal view and to compare to those of native femurs derived from 20 osteoarthritic patient CT scans. Using 3D models of each implant and native femur, sulcus location and orientation were obtained by fitting a spline to connect sulcus points marked at 90°, 105°, 130°, and 145° of femoral flexion (Fig A). Implant reference plane orientations were established using inner facets of distal and posterior flanges. Reference planes of native femurs were defined using protocols developed by Eckhoff et al. [2] where coronal plane was defined using femoral posterior condyles and greater trochanter. In the coronal plane, a best fit line was used to measure sulcus angle and medial-lateral offset with respect to midline at the base of trochlear groove (Fig B).Background
Materials and Methods
Open-wedge high tibial osteotomy (OWHTO) is an operation involving proper load re-distribution in the treatment for medial uni-compartmental arthritis of the knee joint. Therefore, stable fixation is mandatory for safe healing of this additive type of osteotomy to minimize the risk of non-union and loss of correction. For stability, screws provide optimal support and anchorage of the fixator in the condylar area without risking penetration of either the articulating surface. The purpose of the study was to evaluate the screw insertion angle and orientation with an anatomical plate that is post-contoured to the surface geometry of the proximal tibia after OWHTO. From March 2012 to June 2014, 31 uni-planar and 38 bi-planar osteotomies were evaluated. Postoperative computed tomography data obtained after open wedge high tibial osteotomy using a locking plate were used for reconstruction of the 3 dimensional model with Mimics v.16.0 of the proximal tibia and locking plate. Measurement data were compared between 2 groups (gap lesser than or equal to 10 mm (Group 1) and gap greater than 10 mm(Group 2)). These data were also compared between the uniplanar (Group 3) and bi-planar (Group 4) osteotomy groups.Background
Methods
Contemporary total knee systems accommodate for differential sizing between femoral and tibial components to allow surgeons to control soft tissue balancing and optimize rotation. One method some manufacturers use to allow differential sizing involves maintaining coronal articular congruency with a single radius of curvature throughout sizes while clipping the medial-lateral width, called a single coronal geometry system. Registry data show a 20% higher revision rate when the tibial component is smaller than the femur (downsizing) in the DePuy PFC system, a single coronal system, possibly from increased stresses from edge loading or varying articular congruency. We examined a different single coronal geometry knee system, Smith & Nephew Genesis II, to determine if edge loading is present in downsized tibial components by measuring area and location of deviation of the polyethylene articular surface damage. 45 Genesis II posterior-stabilized polyethylene inserts (12 matched and 33 downsized tibial components) were CT scanned. 3D reconstructions were registered to corresponding pristine component reconstructions, and 3D deviation maps of the retrieved articular surfaces relative to the pristine surfaces were created. Each map was exported as a point cloud to a custom MATLAB code to calculate the area and weighted center of deviation of the articular surfaces. An iterative k-means clustering algorithm was used to isolate regions of deviation, and a shrink-wrap algorithm was applied to calculate their areas. The area of deviation was calculated as the sum of all regions of deviation and was normalized to the area of the articular surface. The location of deviation was described using the weighted center of deviation and the location of maximum deviation on the articular surfaces relative to the center of the post (Fig. 1). Pearson product moment correlations were conducted to examine the correlation between length of implantation (LOI) and the medial and lateral areas of deviation for all specimens, matched components, and downsized components.Introduction
Methods
Numerous factors have been hypothesized as contributing to mechanically-assisted corrosion at the head-neck junction of total hip prostheses. While variables attributable to the implant and the patient are amenable to investigation, parameters describing assembly of the component parts can be difficult to determine. Nonetheless, increasing evidence suggests that the manner of intraoperative assembly of modular components plays a critical role in the fretting and corrosion of modular implants. This study was undertaken to measure the magnitude and direction of the impaction forces applied by surgeons in assembling modular head-neck junctions under operative conditions where both the access and visibility of the prosthesis may potentially compromise component fixation. A surrogate consisting of the lower limb with overlying soft tissue was developed to simulate THR performed via a 10cm incision using the posterior approach. The surrogate was modified to match the resistance of the body to retraction of the incision, mobilization of the femur and hammering of the implanted femoral component. An instrumented femoral stem (SL PLUS) was surgically implanted into the bone after attachment of 3 miniature accelerometers (Dytran Inc) in an orthogonal array to the proximal surface of the prosthesis. A 32mm cobalt chrome femoral head was mounted on the trunnion (12/14 taper, machined) of the femoral stem. 15 Board-certified and trainee surgeons replicated their surgical technique in exposing the femur and impacting the modular head on the tapered trunnion. Impaction was performed using an instrumented hammer (5000 Lbf Dytran impact hammer) that provided measurements of the magnitude and temporal variation of the impact force. The components of force acting along the axis aof the neck and in the AP and ML directions were continuously samples using the accelerometers.Introduction
Methods
Lateralizing the center of rotation (COR) of reverse total shoulder arthroplasty (rTSA) has the potential to increase functional outcomes of the procedure, namely adduction range of motion (ROM). However, increased torque at the bone-implant interface as a result of lateralization may provoke early implant loosening, especially in situations where two, rather than four, fixation screws are used. The aim of this study was to utilize finite element (FE) models to investigate the effects of lateralization and the number of fixation screws on micromotion and adduction ROM. Four patient-specific scapular geometries were developed from CT data in 3D Slicer using a semi-automatic threshold technique. A generic glenoid component including the baseplate, a lateralization spacer, and four fixation screws was modelled as a monoblock. Screws were simplified as 4.5 mm diameter cylinders. The glenoid of each scapula was virtually reamed after which the glenoid component was placed. Models were meshed with quadratic tetrahedral elements with an edge length of 1.3 mm. The baseplate and lateralization spacer were assigned titanium material properties (E = 113.8 GPa and ν = 0.34). Screws were also assigned titanium material properties with a corrected elastic modulus (56.7 GPa) to account for omitted thread geometry. Cortical bone was assigned an elastic modulus of 17.5 GPa and Poisson's ratio of 0.3. Cancellous bone material properties in the region of the glenoid were assigned on an element-by-element basis using previously established equations to convert Hounsfield Units from the CT data to density and subsequently to elastic modulus [1]. Fixed displacement boundary conditions were applied to the medial border of each scapula. Contact was simulated as frictional (μ = 0.8) between bone and screws and frictionless between bone and baseplate/spacer. Compressive and superiorly-oriented shear loads of 686 N were applied to the baseplate/spacer. Lateralization of the COR up to 16 mm was simulated by applying the shear load further from the glenoid surface in 4 mm increments (Fig. 1A). All lateralization levels were simulated with four and two (superior and inferior) fixation screws. Absolute micromotion of the baseplate/spacer with respect to the glenoid surface was averaged across the back surface of the spacer and normalized to the baseline configuration considered to be 0 mm lateralization and four fixation screws. Adduction ROM was measured as the angle between the glenoid surface and the humeral stem when impingement of the humeral cup occurred (Fig. 1B).Introduction
Methods
Osteoarthritic (OA) changes to the bone morphology of the proximal tibia may exhibit load transfer patterns during total knee arthroplasty not predicted in models based on normal tibias. Prior work highlighted increased bone density in transverse sections of OA knees in the proximal-most 10mm tibial cancellous bone. Little is known about coronal plane differences, which could help inform load transfer from the tibial plateau to the tibial metaphysis. Therefore, we compared the cancellous bone density in OA and cadaveric (non-OA) subjects along a common coronal plane. This study included nine OA patients (five women, average age 59.1 ± 9.4 years) and 18 cadaver subjects (four women, average age 39.5 ± 14.4 years). Patients (eight with medial OA and one with lateral OA) received pre-operative CT scans as standard-of-care for a unicompartmental knee replacement. Cadavers were scanned at our institution and had no history of OA which was confirmed by gross inspection during dissection. 3D reconstructions of each proximal tibia were made and an ellipse was drawn on the medial and lateral plateau using a previously published method. A coronal section (Figure 1) to standardize the cohort was created using the medial ellipse center, lateral ellipse center, and the tibial shaft center 71.5mm from the tibial spine. On this section, profile lines were drawn from the medial and lateral ellipse centers, with data collected from the first subchondral bone pixel to a length of 20mm. The Hounsfield Units (HU) along each profile line was recorded for each tibia; a representative graphical distribution is shown in Figure 2. The Area Under the Curve (AUC) was calculated for the medial and lateral sides, which loosely described the stiffness profile through the region of interest. To determine differences between the medial and lateral subchondral bone density, the ratio AUC[medial] / AUC[lateral] was compared between the OA and cadaver cohorts using a two-sample t-test. Data from the sole lateral OA patient was mirror-imaged to be included in the OA cohort. The majority of the OA patients appeared to have higher subchondral bone density on the affected side. Figure 3 compares the medial and laterals sides of each group using the AUC ratio method described above. For the cadaver group the AUC was 1.2 +/− 0.22, with a median of 1.1 [0.9 1.6], smaller than the mean AUC for the OA group, which was 1.4 +/− 0.39, with a median of 1.6 [0.93 2.1]. The p-value was 0.06. The increased density observed in OA patients is consistent with asymmetric loading towards the affected plateau, resulting in localized remodeling of cancellous bone from the epiphysis to metaphysis. From the coronal plane, bone was often observed in OA patients bridging the medial plateau to the metaphyseal cortex. Although the cadaver subjects were normal from history and gross inspection, some subjects exhibited early bone density changes consistent with OA. Future work looks to review more OA scans, extend the work to the distal femur, and convert the HU values to bone elastic moduli for use in finite element modelling.
Arthroplasties of hip and knee are associated with blood loss, which may lead to adverse patient outcome. Jehovah's Witnesses do not accept blood transfusion. Performing arthroplasties in Witness patients without transfusion has been a matter of concern. We developed a protocol, which avoids transfusion in arthroplasties of Witness patients, and evaluated the feasibility and safety of the protocol. Our protocol consisted of subcutaneous administration of 4000 U recombinant erythropoietin and 100 mg of intravenous iron supplements when patient's hemoglobin level was less than 10 g/dL in preoperative evaluation. During the operation, cell saver, and plasma expander were used. Postoperatively, recombinant erythropoietin was administered three times a week and iron supplements were administered daily until the hemoglobin level reached 10 g/dL. We evaluated the feasibility of our protocol, perioperative complications and hematologic changes.Introduction
Materials and Methods
Deformity of knee joint causes deviation of mechanical axis in the coronal plane, and the mechanical axis deviation also could adversely affect biomechanics of the ankle joint as well as the knee joint. Particularly, most of the patients undergoing total knee arthroplasty (TKA) have significant preoperative varus malalignment which would be corrected after TKA, the patients also may have significant changes of ankle joint characteristics after the surgery. This study aimed 1) to examine the prevalence of coexisting ankle osteoarthritis (OA) in the patients undergoing TKA due to varus knee OA and to determine whether the patients with coexisting ankle OA have more varus malalignment, and 2) to evaluate the changes of radiographic parameters for ankle joint before and 4 years after TKA. We evaluated 153 knees in 86 patients with varus knee OA who underwent primary TKA. With use of standing whole-limb anteroposterior radiographs and ankle radiographs before and 4 years after TKRA, we assessed prevalence of coexisting ankle OA in the patients before TKA and analyzed the changes of four radiographic parameters before and after TKA including 1) the mechanical tibiofemoral angle (negative value = varus), 2) the ankle joint orientation relative to the ground (positive value = sloping down laterally), 3) ankle joint space, and 4) medial clear space.Introduction
Methods
The purpose of this study was to evaluate the Mid-term results (minimum 5 year) of the use of 36 mm metallic femoral head coupled with 1st generation HXLPE in patients with the age of less than or equal to 50 years-old. This retrospective study included 31 cases sustained hip pain needed Total Hip Replace Arthroplasty. We used cementless stem(FMT, Zimmer, Warsaw, Indiana) at 28 cases and cement stem(Versys, Zimmer, Warsaw, Indiana) at 3 cases. We used Trilogy (Zimmer, Warsaw, Indiana) in all cases as an acetabular cup and Longevity (Zimmer, Warsaw, Indiana) in all cases as a HXLPE. Mean acetabular cup size was 52.88mm. Mean HXLPE liner thickness at 45o was 6.18mm [Fig.1]. Mean Harris hip score was 91(86–96) and all cases obtained more than 15 scores in Merle d'Aubigne and postel method at recent follow ups. All femoral stem showed stable fixation status. Mean acetabular cup Inclination was 50.6o and Anteversion was 23.1o. During follow ups, there was no complication including dislocation, osteolysis, infection and plastic fracture. Bedding-in wear rate was 0.079±0.034mm/yr. And Steady- state was 0.043±0.016mm/yr. In vitro study, 1stgeneration HXLPE showed negative mechanical property changes due to high dose radiation and remelting. So, concerns remained in using HXLPE to active patients. But we checked a good results in terms of functional scores and wear rates. And, there was no major complication during minimal 5 years check ups. So, the authors thought THRA with 36mm- metallic heads on 1st-Generation Highly Cross-linked Polyethylene as a bearing surface could be a good option in less than or equal to 50 years patients.