Implant waste during total hip arthroplasty (THA) represents a significant cost to the USA healthcare system. While studies have explored methods to improve THA cost-effectiveness, the literature comparing the proportions of implant waste by intraoperative technology used during THA is limited. The aims of this study were to: 1) examine whether the use of enabling technologies during THA results in a smaller proportion of wasted implants compared to navigation-guided and conventional manual THA; 2) determine the proportion of wasted implants by implant type; and 3) examine the effects of surgeon experience on rates of implant waste by technology used. We identified 104,420 implants either implanted or wasted during 18,329 primary THAs performed on 16,724 patients between January 2018 and June 2022 at our institution. THAs were separated by technology used: robotic-assisted (n = 4,171), imageless navigation (n = 6,887), and manual (n = 7,721). The primary outcome of interest was the rate of implant waste during primary THA.Aims
Methods
Known risk factors for early periprosthetic femur fracture (PFF) following total hip arthroplasty (THA) include poor bone quality, surgical approach and cementless implants. The association between femoral component size and alignment and the risk of early PFF is not well described. We evaluated radiographic parameters of femoral component sizing and alignment as risk factors for early PFF. From 16,065 primary cementless THA, we identified 66 cases (0.41%) of early PFF (<90 days from index THA) at a single institution between 2016–2020. The stem was unstable and revised in all cases. We matched 60 cases of early PFFs (2:1) to 120 controls based on femoral component model, offset, surgical approach, age, BMI, and sex. Mean age was 67 years; 60% were female. Radiographic assessment of preoperative bone morphology and postoperative femoral component parameters including stem alignment, metaphyseal fill, and medial congruence with the calcar. A multivariable logistic regression was built to identify radiographic risk factors associated with early PPF. Markers of poor preoperative bone quality including canal calcar ratio (p=0.003), canal flare index (p<0.001), anteroposterior canal bone ratio (CBR) (p<0.001) and lateral CBR (p<0.001) were statistically associated with PFF. Valgus alignment (23% versus 12%) (p<0.001) was more prevalent in the PFF group compared to controls, as well as varus alignment of the implant (57% versus 43%). Distance between the medial aspect of the implant and the calcar was greater in cases of PFF (2.5 mm versus 1.4 mm) (p<0.001). Multivariate analysis demonstrated that valgus implant alignment (Odds Ratio (OR) 5) and medial implant-calcar incongruity (OR 2) increased the risk of early PFF. Medial implant-calcar incongruity and valgus alignment of the femoral component were risk factors for early PFF following cementless THA after controlling for age, sex, BMI, approach, proximal femoral morphology, and implant design.
Due to the opioid epidemic in the USA, our service progressively decreased the number of opioid tablets prescribed at discharge after primary hip (THA) and knee (TKA) arthroplasty. The goal of this study was to analyze the effect on total morphine milligram equivalents (MMEs) prescribed and post-discharge opioid repeat prescriptions. We retrospectively reviewed 19,428 patients undergoing a primary THA or TKA between 1 February 2016 and 31 December 2019. Two reductions in the number of opioid tablets prescribed at discharge were implemented over this time; as such, we analyzed three periods (P1, P2, and P3) with different routine discharge MME (750, 520, and 320 MMEs, respectively). We investigated 90-day refill rates, refill MMEs, and whether discharge MMEs were associated with represcribing in a multivariate model.Aims
Methods
Due to the opioid epidemic, our service developed a cultural change highlighted by decreasing discharge opioids after lower extremity arthroplasty. However, concern of potentially increasing refill requests exists. As such, the goal of this study was to analyze whether decreased discharge opioids led to increased postoperative opioid refills. We retrospectively reviewed 19,428 patients undergoing a primary hip or knee arthroplasty at a single institution from 2016–2019. Patients that underwent secondary procedures within that timeframe were excluded. Two-thousand two-hundred and forty-one patients (12%) were on narcotics preoperatively or had chronic pain syndrome. Two reductions in routine discharge narcotics were performed over this timeframe. First, 8,898 patients routinely received 750 morphine milligram equivalents (MMEs). After the first reduction, 4,842 patients routinely received 520 MMEs. After a second reduction, 5,688 patients routinely received 320 MMEs. We analyzed refill rates, refill MMEs, and whether discharge MMEs were associated with refill MMEs in a multivariate model.Introduction
Methods
This combined clinical and in vitro study aimed to determine the incidence of liner malseating in modular dual mobility (MDM) constructs in primary total hip arthroplasties (THAs) from a large volume arthroplasty centre, and determine whether malseating increases the potential for fretting and corrosion at the modular metal interface in malseated MDM constructs using a simulated corrosion chamber. For the clinical arm of the study, observers independently reviewed postoperative radiographs of 551 primary THAs using MDM constructs from a single manufacturer over a three-year period, to identify the incidence of MDM liner-shell malseating. Multivariable logistic regression analysis was performed to identify risk factors including age, sex, body mass index (BMI), cup design, cup size, and the MDM case volume of the surgeon. For the in vitro arm, six pristine MDM implants with cobalt-chrome liners were tested in a simulated corrosion chamber. Three were well-seated and three were malseated with 6° of canting. The liner-shell couples underwent cyclic loading of increasing magnitudes. Fretting current was measured throughout testing and the onset of fretting load was determined by analyzing the increase in average current.Aims
Methods
Custom flange acetabular components (CFACs) are a patient-specific option for addressing large acetabular defects at revision total hip arthroplasty (THA), but patient and implant characteristics that affect survivorship remain unknown. This study aimed to identify patient and design factors related to survivorship. A retrospective review of 91 patients who underwent revision THA using 96 CFACs was undertaken, comparing features between radiologically failed and successful cases. Patient characteristics (demographic, clinical, and radiological) and implant features (design characteristics and intraoperative features) were collected. There were 74 women and 22 men; their mean age was 62 years (31 to 85). The mean follow-up was 24.9 months (Aims
Patients and Methods
Custom flanged acetabular components (CFAC) have been shown to be effective in treating complex acetabular reconstructions in revision total hip arthroplasty (THA). However, the specific patient factors and CFAC design characteristics that affect the overall survivorship remain unclear. Once the surgeon opts to follow this treatment pathway, numerous decisions need to be made during the pre-operative design phase and during implantation, which may influence the ultimate success of CFAC. The goal of this study was to retrospectively review the entire cohort of CFAC cases performed at a large volume institution and to identify any patient, surgeon, or design factors that may be related to the long-term survival of these prostheses. We reviewed 96 CFAC cases performed in 91 patients between 2004 and 2017, from which 36 variables were collected spanning patient demographics, pre-operative clinical and radiographic features, intraoperative information, and implant design characteristics. Patient demographics and relevant clinical features were collected from individual medical records. Radiographic review included analysis of pre-operative radiographs, computer tomographic (CT) scans, and serial post-operative radiographs. Radiographic failure was defined as loosening or gross migration as determined by a board-certified orthopedic surgeon. CFAC implant design characteristics and intra-operative features were collected from the design record, surgical record and post-operative radiograph for each case respectively. Two sets of statistical analyses were performed with this dataset. First, univariate analyses were performed for each variable, comprising of a Pearson chi-square test for categorical variables and an independent t-test for continuous variables. Second, a random forest supervised machine learning method was applied to identify the most influential variables within the dataset, which were then used to perform a bivariable logistic regression to generate odds ratios. Statistical significance for this study was set at p < 0.05.Introduction
Methods