Advertisement for orthosearch.org.uk
Results 1 - 15 of 15
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 679 - 687
1 Jun 2023
Lou Y Zhao C Cao H Yan B Chen D Jia Q Li L Xiao J

Aims

The aim of this study was to report the long-term prognosis of patients with multiple Langerhans cell histiocytosis (LCH) involving the spine, and to analyze the risk factors for progression-free survival (PFS).

Methods

We included 28 patients with multiple LCH involving the spine treated between January 2009 and August 2021. Kaplan-Meier methods were applied to estimate overall survival (OS) and PFS. Univariate Cox regression analysis was used to identify variables associated with PFS.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 55 - 55
4 Apr 2023
Ge Q Shi Z Ying J Chen J Yuan W Wang P Chen D Feng X Tong P Jin H
Full Access

TGF-β/Smad2 signaling is considered to be one of the important pathways involved in osteoarthritis (OA) and protein phosphatase magnesium-dependent 1A (PPM1A) functions as an exclusive phosphatase of Smad2 and regulates TGF-β signaling, here, we investigated the functional role of PPM1A in OA pathogenesis.

PPM1A expressions in both human OA cartilage and experimental OA mice chondrocytes were analyzed immunohistochemically. Besides, the mRNA and protein expression of PPM1A induced by IL-1β treatment were also detected by q-PCR and immunofluorescence in vitro. OA was induced in PPM1A knockout (KO) mice by destabilization of the medial meniscus (DMM), and histopathological examination was performed. OA was also induced in wild-type (WT) mice, which were then treated with an intra-articular injection of a selective PPM1A inhibitor for 8 weeks.

PPM1A protein expressions were increased in both human OA cartilage and experimental OA mice chondrocytes. We also found that treatment with IL-1β in mouse primary chondrocytes significantly increased both mRNA and protein expression of PPM1A in vitro. Importantly, our data showed that PPM1A deletion could substantially protect against surgically induced OA. Concretely, the average OARSI score and quantification of BV/TV of subchondral bone in KO mice were significantly lower than that in WT mice 8 weeks after DMM surgery. Besides, TUNEL staining revealed a significant decrease in apoptotic chondrocytes in PPM1A-KO mice with DMM operation. With OA induction, the rates of chondrocytes positive for Mmp-13 and Adamts-5 in KO mice were also significantly lower than those in WT mice. Moreover, compared with WT mice, the phosphorylation of Smad2 in chondrocytes was increased in KO mice underwent DMM surgery. However, articular-injection with SD-208, a selective inhibitor of TGF-β/Smad2 signaling could significantly abolish the chondroprotective phenotypes in PPM1A-KO mice. Additionally, both cartilage degeneration and subchondral bone subchondral bone sclerosis in DMM model were blunted following intra-articular injection with BC-21, a small-molecule inhibitor for PPM1A.

Our study demonstrated that PPM1A inhibition attenuates OA by regulating TGF-β/Smad2 signaling. Furthermore, PPM1A is a potential target for OA treatment and BC-21 may be employed as alternative therapeutic agents for the management of OA.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 120 - 120
1 Mar 2017
Shemesh S Robinson J Overley S Moucha C Chen D
Full Access

Intro

Sciatic nerve injury (SNI) is a rare and potentially devastating complication after total hip arthroplasty (THA). Neural monitoring has been found in several studies to be useful in preventing SNI, but can be difficult to practically implement during surgery. In this study, we examine the results of using a handheld nerve stimulator for intraoperative sciatic nerve monitoring during complex THA requiring limb lengthening and/or significant manipulation of the sciatic nerve.

Methods

We retrospectively reviewed a consecutive series of 11 cases (9 patients, 11 hips) with either severe developmental dysplasia of the hip (Crowe 3–4) or other underlying conditions requiring complex hip reconstruction involving significant leg lengthening and/or nerve manipulation. Sciatic nerve function was monitored intra-operatively with a handheld nerve stimulator by obtaining pre- and post-reduction conduction thresholds during component trialling. The results of nerve stimulation were then used to influence intraoperative decision- making (downsizing components, shortening osteotomy).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 133 - 133
1 May 2016
Fields A Walsh A Dieterich J Carbonaro C Mcdonough D Walsh M Chen D Bronson M Moucha C
Full Access

Background

Several studies have shown that Staphylococcus aureus (S.aureus) nasal colonization is associated with postoperative surgical site infection and that preoperative decolonization can reduce infection rates. Up to 30% of joint replacement patients have positive S.aureus nasal swabs and patient risk factors for colonization remain largely unknown. Many joint replacement patients continue to undergo surgery without being screened.

Study Question

Is there a specific patient population at increased risk of S.aureus nasal colonization?


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 145 - 145
1 Mar 2013
MacDessi S Chen D Seeto B Wernecke G
Full Access

AIM

Tibial component design has be been scrutinized in a number of studies in an attempt to improve tibial coverage in total knee arthroplasty. However, very few have controlled for both component rotation and resultant changes to posterolateral tibial tray overhang and posteromedial underhang. We hypothesize that asymmetrical tibial components can provide greater coverage than symmetrical trays without increasing overhang.

METHODS

The 6 most commonly used tibial trays on the Australian Joint Registry (2009) were superimposed on MRI slices of normal knees to assess tibial component overhang, underhang and percent coverage. Rotational alignment in this analysis was based upon the line joining the junciton of the medial and middle 1/3 of the patellar tendon and the PCL insertion.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 118 - 118
1 Mar 2013
MacDessi S Chen D Wernecke G Seeto B Chia S
Full Access

Introduction

Total knee arthroplasty is a painful operation. Peri-articular local anesthetic injections reduce post-operative pain and assist recovery. It is inconclusive whether intra-operative injections of peri-articular corticosteroids are of benefit. Clinical Question: In patients with osteoarthritis who are undergoing TKA, does the addition of high or low dose corticosteroid to peri-articular injections of local anesthetic and adrenaline improve post-operative pain and range of motion?

Methods

A prospective, randomized, double-blinded study was undertaken to assess the efficacy of adding peri-articular corticosteroids to intra-operative, peri-articular high volume local anaesthetic in post-operative pain management following TKA. 127 patients were randomised into three groups receiving local anaesthetic alone (control) or either low dose (40 mg) or high dose (80 mg) peri-articular corticosteroid plus local anaesthetic. Primary outcomes included ROM and visual analog pain scores (VAS). Pain was defined as the worst pain lasting for more than 20 minutes, measured at both rest (RVAS) and during activity (AVAS).


Introduction

It is widely accepted that computer navigation more reliably restores neutral mechanical alignment than conventional instrumentation in total knee arthroplasty (TKA) surgery. Recently, magnetic resonance (MR) based instrumentation has been introduced to the market with a rapid growth in usage. However, a paucity of comparative data still exists on the precision of magnetic resonance (MR) based instruments in achieving acceptable lower limb alignment when compared to other validated techniques. In this analysis, we compare the radiographic outcomes of 3 techniques to achieve satisfactory prosthetic alignment by 2 surgeons using the same prosthesis and surgical technique.

Methods

A series of 180 patients who had undergone TKA surgery were included in this study. Two fellowship-trained knee surgeons performed all surgeries using the same cemented, posterior stabilized implants (NexGen, Zimmer, Warsaw, In). Patients were stratified in to 3 groups according to the technique used to align the knee; 1. Conventional Intra-medullary Instrumentation, 2. Computer Navigation (Orthosoft), and 3. MR-based guides (Zimmer PSI). All patients underwent a post-operative CT Perth Protocol to assess coronal, sagittal and rotational alignment of the femoral and tibial implants. A radiographer who was blinded to the alignment technique used performed all radiographic measurements. Outliers were defined at a deviation of more than 3 degrees from the mechanical axis in all planes of motion.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 143 - 143
1 Mar 2013
Chen D Bertollo N Stanford R Harper W Walsh W
Full Access

Aim

Cementless prosthesis is one of the major bone-implant interface fixation methods in total joint replacement. Grit blasted surface, hydroxyapatite coated surface and plasma sprayed metallic porous coating have been popularly used. The latter has demonstrated higher bone implant mechanical stability in previous laboratory study in early and middle stages. However, question remains what the mechanism is to make it performing better and how to improve them further. This study is designed to examine the mode of failure in bone-implant interface in a sheep model.

Method

Plasma sprayed porous coated (TiPL); hydroxyapatite (HA) coated and and grit blasted (TiGB) titanium implants were examined in the study. Each type has 36 specimens. Implants were inserted into cortical bones in a press-fit fashion in a total of 22 sheep bilateral hind limbs. Specimens were retrieved at 4 weeks and 12 weeks. Push- out testing was performed to just reach ultimate failure. Failed bone-implant interface were investigated by histology and BSEM. The percentage of failure at bone-coating interface, bone itself fracture, coating itself failure, and coating-substrate dissociation were measured by BSEM.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 144 - 144
1 Mar 2013
Chen D Bertollo N Harper W Stanford R Walsh W
Full Access

This study was performed to compare the mechanism of bone-implant integration and mechanical stability among three popularly used cementless implant surfaces. Plasma sprayed porous surface (TiPL), grit-blasted rough surface (TiGB), and hydroxyapatite coated implant surface (HA) were tested in a sheep model at 4 and 12 weeks. The integration patterns were investigated using histology, histomorphometry, and mechanical strength by push-out test. All three groups demonstrated early bone ongrowth on their surfaces, with much of the ongrowth resembling contact osteogenesis. TiPL group showed bone anchorage into porous coating with new bone ingrowth into the pores. HA group revealed small cracks at its coating at 12 weeks time point. Plasma sprayed porous surface also demonstrated its superior mechanical stability maybe reinforced by its bone anchorage, whearas, HA surface exhibited higher osteoconductivity with highest ongrowth rate.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 34 - 34
1 Mar 2013
MacDessi S Chen D
Full Access

Introduction & Aims

Intravenous administration of tranexamic acid (TXA) has been shown to be effective in reducing blood loss and transfusion requirements in total knee arthroplasty (TKA). However, concern exists that I.V. TXA may heighten the risk of venous thrombo-embolism. The intra-articular administration of TXA is an attractive and simple option to deliver this agent locally with minimal systemic effects on inducing hypercoagubale states. In this study, we analysed the effect of varying dosages of intra-articular tranexamic acid on blood loss in TKA.

Methods

176 patients who underwent a unilateral TKA for osteoarthritis were retrospectively analysed. Patients were excluded if they underwent a revision knee arthroplasty, concurrent removal of hardware, extensive synovectomy, or lateral patellar retinacular release. All patients underwent a primary cemented posterior stabilised TKA by 2 surgeons using a medial parapatellar approach. Tourniquet was only inflated for initial exposure and intra-articular drains were not used. Patients were separated into three groups; a control group (n=56) who did not receive TXA, and 2 treatment groups who received intra-articular TXA with doses of 1500 mg (n=60) or 3000 mg (n=60). Once the wound was closed, tranexamic acid was injected intra-articularly via an epidural pain catheter. Haemoglobin (Hb) levels were taken pre-operatively and on post-operative days 1 and 2. The primary outcome measure was mean difference in Hb drop between the three groups.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 124 - 124
1 Sep 2012
Lovric V Chen D Oliver R Yu Y Genin F Walsh W
Full Access

Fibrocartilaginous entheses are formed through endochondral ossification and characterized by four zones morphologically separated into tendon, uncalcified fibrocartilage, calcified fibrocartilage and bone [1]. These zones are not successfully regenerated following surgical repair. Demineralized Bone (DBM) presented at the tendon bone interface may improve healing between tendon and bone.

Fifty six female nude rats were randomly allocated into either a control reconstruction or treatment group (DBM at the tendon-bone healing site). A modified rodent model of anterior cruciate ligament reconstruction was adopted [2]. Animals were sacrificed at 2, 4 and 6 weeks following surgery. Four rats per group were prepared for histology at each time point while eight rats were culled for biomechanical testing at 4 and 6 week time points. ANOVA and post hoc tests were used to examine differences which were considered significant at p < 0.05.

The surgical procedure was well tolerated. Macroscopic dissection did not reveal any infection and all joint surfaces appeared normal. An intra-articular graft between the femur and tibia was present in all specimens. Mechanical differences were noted between groups. Peak loads were significantly higher in treatment group at 4 and 6 weeks (6.0 ± 3.6N and 9.1 ± 2.6 N, respectively) compared to controls (2.9 ± 1.9 N and 5.8 ± 2.7 N). No statistical differences were found in graft stiffness between the groups at 4 or 6 week time points. Histology showed an initial influx of inflammatory cells coupled with formation of a loose disorganized fibrovascular interface layer between tendon and bone in both groups. By the 6 weeks the interface layer in the DBM group fused into the newly formed bone to create a continuum between the tendon and bone, in an interdigitated fashion, containing Sharpy's like fibres. In the control group the continuum was less apparent with evidence of large areas of discontinuity between the two zones. A thicker region of newly formed woven bone with increased osteoblast activity along the bone tunnel was evident in the DBM group.

DBM has the potential to increase the quality of repair following surgical procedures involving reattachment of tendon to bone.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 349 - 349
1 Sep 2012
Heyse T Chen D Kelly N Boettner F Wright T Haas S
Full Access

Introduction

Oxidized zirconium (OxZr) is used as a ceramic surface for femoral components in total knee arthroplasty (TKA). The aim of this study was to investigate its performance by examining retrieved femoral components and their corresponding PE inserts in matched comparison with conventional chrome/cobalt/molybdenum alloy (CrCoMo).

Methods

11 retrieved posterior stabilized (PS) TKA with an OxZr femoral component were included. From a cohort of 56 retrieved TKA with CrCoMo femoral components, pairs were matched according to duration of implantation, patient age, reason for revision, and BMI. The retrieved tibial polyethylene (PE) inserts were analyzed for wear using the Hood classification. Femoral components were optically viewed at 8–32x magnification and screened for scratching, pitting, delamination, and striation. Profilometry was performed to measure surface roughness of the OxZr components using a non-contact white light profiler.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 153 - 153
1 May 2012
Goldberg J Walsh W Chen D
Full Access

The diagnosis and treatment of disorders of the long head of the biceps tendon remains controversial. There is uncertainty as to the role of the long head of biceps and it can be difficult to determine whether the patient's pathology is coming from the biceps or other adjacent structures. In addition, the appropriate type of treatment remains controversial.

We retrospectively reviewed the files of the senior author's experience in over 4000 arthroscopic shoulder procedures. We examined cases involving isolated biceps pathology, excluding those patients with rotator cuff tears and labral pathology, involving 92 biceps tenotomies and 103 biceps tenodeses.

Our analysis supports the benefit of clinical examination over all types of radiological investigations. The benefits and technique of biceps tenodesis is described including surgical technique. Irritation by PLA interference screw is examined. A paradigm is put forward to help in diagnosis and management of these lesions.

Long head of biceps pathology is a significant cause of shoulder pain in association with other shoulder problems and in isolation. Biceps tenodesis and tenotomy is an efficacious way of dealing with this pathology.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 257 - 264
1 Feb 2012
Raskob GE Gallus AS Pineo GF Chen D Ramirez L Wright RT Lassen MR

In order to compare the effect of oral apixaban (a factor Xa inhibitor) with subcutaneous enoxaparin on major venous thromboembolism and major and non-major clinically relevant bleeding after total knee and hip replacement, we conducted a pooled analysis of two previously reported double-blind randomised studies involving 8464 patients. One group received apixaban 2.5 mg twice daily (plus placebo injection) starting 12 to 24 hours after operation, and the other received enoxaparin subcutaneously once daily (and placebo tablets) starting 12 hours (± 3) pre-operatively. Each regimen was continued for 12 days (± 2) after knee and 35 days (± 3) after hip arthroplasty. All outcomes were centrally adjudicated. Major venous thromboembolism occurred in 23 of 3394 (0.7%) evaluable apixaban patients and in 51 of 3394 (1.5%) evaluable enoxaparin patients (risk difference, apixaban minus enoxaparin, -0.8% (95% confidence interval (CI) -1.2 to -0.3); two-sided p = 0.001 for superiority). Major bleeding occurred in 31 of 4174 (0.7%) apixaban patients and 32 of 4167 (0.8%) enoxaparin patients (risk difference -0.02% (95% CI -0.4 to 0.4)). Combined major and clinically relevant non-major bleeding occurred in 182 (4.4%) apixaban patients and 206 (4.9%) enoxaparin patients (risk difference -0.6% (95% CI -1.5 to 0.3)).

Apixaban 2.5 mg twice daily is more effective than enoxaparin 40 mg once daily without increased bleeding.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 313 - 313
1 Sep 2005
Wines A Chen D Lynch B Stephens M
Full Access

Introduction and Aims: Despite being a relatively common condition in childhood, there is little information in the world literature documenting the foot deformities seen in the Hereditary Motor and Sensory Neuropathies (HMSN). The aim of this paper was to thoroughly investigate the foot deformities seen in children with HMSN.

Method: We reviewed 104 feet from 52 children with HMSN seen for the first time in clinics at the Central Remedial Clinic, Dublin and The Children’s Hospital at Westmead, Sydney between January 1996 and June 2003. All patients were reviewed by a consultant neurologist and orthopaedic surgeon. The data we collected included: HMSN type, sex, age at first presentation, type of foot deformity, bilaterality of deformity, symmetricality of deformity, whether surgery had been required, age at surgery and the details of the surgery performed. We divided surgery types into soft tissue procedures alone and combined soft tissue and bony procedures.

Results: Sixty-nine feet had a cavovarus deformity, 23 feet had a planovalgus deformity and 12 feet had no significant deformity. All cases with deformity had bilateral involvement, and of those with deformity, only 45% had symmetrical involvement. In HMSN I, III, IV, V and X linked HMSN, cavovarus was the most common deformity. However, in HMSN II, 55% of feet had a planovalgus deformity, 36% had a cavovarus deformity and 9% no deformity. Forty-three feet required surgery of some type. Thirty-four feet with a cavovarus deformity had surgery, 17 required soft tissue surgery and 17 combined bony and soft tissue surgery. Nine feet with a planovalgus deformity had surgery, seven required soft tissue surgery alone, and two had combined surgery.

Conclusion: Cavovarus is the most common foot deformity seen in patients with HMSN. However, a planovalgus deformity is not uncommon, and in HMSN II, planovalgus is seen more frequently than cavovarus. Surgical intervention was required in just under half of the feet with deformity. Surgery, and in particularly combined soft tissue and bony surgery, is required more often to treat feet with a cavovarus deformity than with a planovalgus deformity.