Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 8 - 8
10 Jun 2024
Airey G Aamir J Chapman J Tanaka H Elbannan M Singh A Mangwani J Kyaw H Jeyaseelan L Mason L
Full Access

Background

Research on midfoot injuries have primarily concentrated on the central column and the Lisfranc ligament without amassing evidence on lateral column injuries. Lateral column injuries have historically been treated with Kirschner wire fixation when encountered.

Objective

Our aim in this study was to analyse lateral column injuries to the midfoot, their method of treatment and the radiological lateral column outcomes. Our nul hypothesis being that fixation is required to obtain and maintain lateral column alignment.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 8 - 8
4 Jun 2024
Safdar NZ Chapman G Hopwood J Brockett C Redmond A
Full Access

Ankle fusion (AF), a durable intervention for ankle arthritis, has been the management of choice but restricts mobility. Recently, total ankle replacement (TAR) has been offered to patients looking to maintain mobility. The aim was to compare the biomechanics of AF and TAR while walking on inverted and everted slopes which create a greater demand for complex foot mobility than level walking. A ten-camera motion detection setup captured trials as patients walked in both directions over a 5⁰ lateral slope with embedded force plates. Moments (Nm/Kg) across the knee and ankle were exported from Visual 3D in the sagittal and frontal plane, and data were reported as means with 95% confidence intervals. 15 patients were recruited (6 TAR, 9 AF). The median age, follow-up and BMI was 67 years, 4 years and 35.8 kg/m² in AF, and 73 years, 7 years and 28.1 kg/m² in TAR, respectively. During inverted slope walking (4 TAR, 7 AF), abduction moments across (i) the knee: TAR 0.38 (0.37–0.39) vs AF 0.37 (0.27–0.52) and (ii) the ankle: TAR 0.20 (0.13–0.27) vs AF 0.25 (0.18–0.32), and extension moments across (i) the knee: TAR 0.68 (0.38–0.97) vs AF 0.85 (0.69–1.01) and (ii) the ankle: TAR 1.46 (1.30–1.62) vs AF 1.30 (1.08–1.52). During everted walking (5 TAR, 7 AF), abduction moments across (i) the knee: TAR 0.41 (0.30–0.52) vs AF 0.46 (0.27–0.66) and (ii) the ankle: TAR 0.24 (0.11–0.38) vs AF 0.26 (0.18–0.33), and extension moments across (i) the knee: TAR 0.76 (0.54–0.99) vs AF 0.93 (0.72–1.14) and (ii) the ankle: TAR 1.39 (1.19–1.59) vs AF 1.26 (1.04–1.48). There were no differences in abduction moments during inverted or everted slope walking. However, patients with AF had increased extension moments across the knee, particularly on inverted slopes, suggesting that AF creates a greater demand for knee compensation than TAR.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 12 - 12
4 Jun 2024
Chapman J Choudhary Z Gupta S Airey G Mason L
Full Access

Introduction

Treatment pathways of 5th metatarsal fractures are commonly directed based on fracture classification, with Jones types for example, requiring closer observation and possibly more aggressive management.

Primary objective

To investigate the reliability of assessment of subtypes of 5th metatarsal fractures by different observers.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 34 - 34
1 Jun 2023
Airey G Chapman J Mason L Harrison W
Full Access

Introduction

Open fragility ankle fractures involve complex decision making. There is no consensus on the method of surgical management. Our aim in this study was to analyse current management of these patients in a major trauma centre (MTC).

Materials & Methods

This cohort study evaluates the management of geriatric (≥65years) open ankle fractures in a MTC (November 2020–November 2022). The method, timing(s) and personnel involved in surgical care were assessed. Weightbearing status over the treatment course was monitored. Patient frailty was measured using the clinical frailty score (CFS).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 98 - 98
11 Apr 2023
Williams D Chapman G Esquivel L Brockett C
Full Access

To be able to assess the biomechanical and functional effects of ankle injury and disease it is necessary to characterise healthy ankle kinematics. Due to the anatomical complexity of the ankle, it is difficult to accurately measure the Tibiotalar and Subtalar joint angles using traditional marker-based motion capture techniques. Biplane Video X-ray (BVX) is an imaging technique that allows direct measurement of individual bones using high-speed, dynamic X-rays.

The objective is to develop an in-vivo protocol for the hindfoot looking at the tibiotalar and subtalar joint during different activities of living.

A bespoke raised walkway was manufactured to position the foot and ankle inside the field of view of the BVX system. Three healthy volunteers performed three gait and step-down trials while capturing Biplane Video X-Ray (125Hz, 1.25ms, 80kVp and 160 mA) and underwent MR imaging (Magnetom 3T Prisma, Siemens) which were manually segmented into 3D bone models (Simpleware Scan IP, Synopsis). Bone position and orientation for the Talus, Calcaneus and Tibia were calculated by manual matching of 3D Bone models to X-Rays (DSX Suite, C-Motion, Inc.). Kinematics were calculated using MATLAB (MathWorks, Inc. USA).

Pilot results showed that for the subtalar joint there was greater range of motion (ROM) for Inversion and Dorsiflexion angles during stance phase of gait and reduced ROM for Internal Rotation compared with step down. For the tibiotalar joint, Gait had greater inversion and internal rotation ROM and reduced dorsiflexion ROM when compared with step down.

The developed protocol successfully calculated the in-vivo kinematics of the tibiotalar and subtalar joints for different dynamic activities of daily living. These pilot results show the different kinematic profiles between two different activities of daily living. Future work will investigate translation kinematics of the two joints to fully characterise healthy kinematics.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 1004 - 1016
26 Nov 2021
Wight CM Whyne CM Bogoch ER Zdero R Chapman RM van Citters DW Walsh WR Schemitsch E

Aims

This study investigates head-neck taper corrosion with varying head size in a novel hip simulator instrumented to measure corrosion related electrical activity under torsional loads.

Methods

In all, six 28 mm and six 36 mm titanium stem-cobalt chrome head pairs with polyethylene sockets were tested in a novel instrumented hip simulator. Samples were tested using simulated gait data with incremental increasing loads to determine corrosion onset load and electrochemical activity. Half of each head size group were then cycled with simulated gait and the other half with gait compression only. Damage was measured by area and maximum linear wear depth.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 38 - 38
1 Mar 2021
Vasiljeva K Lunn D Chapman G Redmond A Wang L Thompson J Williams S Wilcox R Jones A
Full Access

Abstract

Objectives

The importance of cup position on the performance of total hip replacements (THR) has been demonstrated in in vitro hip simulator tests and clinically. However, how cup position changes during gait has not been considered and may affect failure scenarios. The aim of this study was to assess dynamic cup version using gait data.

Methods

Pelvic movement data for walking for 39 unilateral THR patients was acquired (Leeds Biomedical Research Centre). Patient's elected walking speed was used to group patients into high- and low-functioning (mean speed, 1.36(SD 0.09)ms−1 and 0.85(SD 0.08)ms−1 respectively). A computational algorithm (Python3.7) was developed to calculate cup version during gait cycle. Inputs were pelvic angles and initial cup orientation (assumed to be 45° inclination and 7° version, anterior pelvic plane was parallel to radiological frontal plane). Outputs were cup version angles during a gait cycle (101 measurements/cycle). Minimum, maximum and average cup version during gait cycle were measured for each patient. Two-sample t-test (p=0.05) was used to compare groups.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 31 - 31
1 Mar 2021
Hopwood J Redmond A Chapman G Richards L Collins S Brockett C
Full Access

Abstract

Objectives

Implant loosening remains a common cause of total ankle replacement (TAR) revision, and has been associated with wear-mediated osteolysis. Limited pre-clinical studies for TARs have been reported and the variety of experiment settings make it difficult to compare wear rates. Factors such as simulator control mechanism; whether pneumatic or electromechanical, may influence the integrity of the simulator outputs with respect to input profiles. This study compares the wear of a TAR, tested in electromechanical and pneumatic experimental simulators under identical input conditions.

Methods

Twelve medium BOX® (MatOrtho Ltd) TARs (n=6 for each simulator) were tested in an electromechanical and pneumatic knee simulator (Simulation Solutions, UK) for 3 million cycles (Mc). Standard ‘Leeds’ displacement-controlled inputs were used. Kinematic performance was investigated by comparing the output profiles against the maximum demanded input values. The lubricant used was 25% new-born calf serum and wear was determined gravimetrically.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 64 - 64
1 Mar 2021
Esquivel L Chapman G Holt C Brockett C Williams D
Full Access

Abstract

Skeletal kinematics are traditionally measured by motion analysis methods such as optical motion capture (OMC). While easy to carry out and clinically relevant for certain applications, it is not suitable for analysing the ankle joint due to its anatomical complexity. A greater understanding of the function of healthy ankle joints could lead to an improvement in the success of ankle-replacement surgeries. Biplane video X-ray (BVX) is a technique that allows direct measurement of individual bones using highspeed, dynamic X-Rays.

Objective

To develop a protocol to quantify in-vivo foot and ankle kinematics using a bespoke High-speed Dynamic Biplane X-ray system combined with OMC.

Methods

Two healthy volunteers performed five level walks and step-down trials while simultaneous capturing BVX and synchronised OMC. participants undertook MR imaging (Magnetom 3T Prisma, Siemens) which was manually segmented into 3D bone models (Simpleware Scan IP, Synopsis). Bone position and orientation for the Talus, Tibia and Calcaneus were calculated by manual matching of 3D Bone models to X-Rays (DSX Suite, C-Motion, Inc.). OMC markers were tracked (QTM, Qualisys) and processed using Visual 3D (C-motion, Inc.).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 52 - 52
1 Oct 2020
Dalury DF Chapman DM
Full Access

Introduction

One of the main considerations in the revision TKR setting is deciding on the level of constraint to be utilized once the bone defects have been reconstructed. There is a fear that employing a maximally constrained insert could compromise long term results. We report on a consecutive series of full tibial and femoral component revisions all treated with a maximally conforming insert and followed for a minimum of 5 years.

Materials and Methods

The study group consisted of 76 consecutive revision TKR in 76 patients where both the femur and the tibia were revised. 4 patients died and 6 were lost to follow up. Final cohort had an average age of 70 years, average BMI of 31 and there were 39 males in the group. Average time to revision was 7 years (range 1–10 years) and the reasons for revision included infection in 28, aseptic loosening 26, osteolysis and poly wear in 9 and 13 other. All were treated with the same revision system and an identical maximally conforming tibial rotating platform insert and followed for an average of 7 years (range 5–14 years).


Aims

Enhanced perioperative protocols have significantly improved patient recovery following primary total knee arthroplasty (TKA). Little has been investigated the effectiveness of these protocols for revision TKA (RTKA). We report on a matched group of aseptic revision and primary TKA patients treated with an identical pain and rehabilitation programmes.

Methods

Overall, 40 aseptic full-component RTKA patients were matched (surgical date, age, sex, and body mass index (BMI)) to a group of primary cemented TKA patients. All RTKAs had new uncemented stemmed femoral and tibial components with metaphyseal sleeves. Both groups were treated with an identical postoperative pain protocol. Patients were followed for at least two years. Knee Society Scores (KSS) at six weeks and at final follow-up were recorded for both groups.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 64 - 64
1 Feb 2020
Hopwood J Redmond A Chapman G Richards L Collins S Brockett C
Full Access

Background

Total ankle arthroplasty (TAA) is an alternative to ankle arthrodesis, replacing the degenerated joint with a mechanical motion-preserving alternative. Implant loosening remains a primary cause of TAA revision, and has been associated with wear-mediated osteolysis. Differing implant designs have a major influence on the wear performance of joint replacements. Providing a range of implant sizes allows surgeons a greater intra-operative choice for varying patient anatomy and potential to minimise wear. Minimal pre-clinical testing exists in the literature that investigates the effect of implant size on the wear behaviour. The aim of this study therefore was to investigate the effect of two different implant sizes on the wear performance of a TAA.

Materials & Methods

Six ‘medium’ and six ‘extra small’ BOX® (MatOrtho Ltd, UK) TAA implants, of the same conceptual design and polyethylene insert thickness, were tested in a modified 6 station pneumatic knee simulator. 5 million cycles (Mc) of wear simulation were completed for each implant size, under kinematics aiming to replicate an ankle gait cycle (Figure 1) [1]. The simulator used had six degrees of freedom, of which four were controlled. The maximum axial load was 3150N, equivalent to 4.5 times body weight of a 70kg individual. The flexion profile ranged from −15° plantarflexion to 15° dorsiflexion. Rotation about the tibial component ranged from −2.3° of internal rotation to 8° external rotation, and anterior/posterior (AP) displacement ranged from 3.1 mm anterior to −0.9 mm posterior displacement. The lubricant used was 25% bovine serum supplemented with 0.04% sodium azide to prevent bacterial degradation. The wear of the TAA polyethylene inserts were determined gravimetrically after each Mc, with unloaded soak controls used to compensate for the uptake of moisture by the polyethylene.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 51 - 51
1 Feb 2020
Chapman R Moschetti W Van Citters D
Full Access

Introduction

Total knee arthroplasty (TKA) is highly successful due to pain reduction, patient satisfaction, and increased range of motion (ROM) during activities of daily living (ADL). ROM recovery is critical for successful outcomes, however ROM values are typically captured during routine physical therapy (PT) appointments via simplified measures (e.g. goniometric maximum passive ROM). These measures are imprecise, potentially neglecting patients’ home experiences. Accordingly, improved measurement methods are necessary to realistically represent ROM recovery. A validated inertial measurement unit (IMU) method continuously capturing knee ROM was deployed assessing knee ROM recovery during PT appointments and during patients’ routine daily experiences. Our objectives were to 1) continuously capture knee ROM pre-/post-TKA via IMUs and 2) divide each day's data to PT/non-PT segments comparing ‘gold standard’ ROM measurements (PT periods) with non-invasive home measurements (non-PT periods). Given patients are verbally/physically encouraged during PT, we hypothesized PT and non-PT metrics would be significantly different including 1) greater kinematics, 2) shorter times, and 3) greater activity level during PT compared to non-PT.

Methods

Following IRB approval, IMUs captured long duration, continuous (8–12 hours/day, ∼50 days) knee ROM pre-/post-TKA. Post-TKA metrics were subdivided to PT/non-PT time periods including maximum ROM, gait phase ROMs (stance/swing), gait times (stride/stance/swing), and activity level. Clinical ROM and patient reported outcome measures (PROMs) were also captured before/after TKA. Statistical comparisons were completed between pre-TKA, post-TKA PT, and post-TKA non-PT metrics. Correlation analyses were completed between IMU, clinical ROM, and PROMs.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 49 - 49
1 Feb 2020
Chapman R Moschetti W Van Citters D
Full Access

Introduction

With many stakeholders, healthcare decisions are complex. However, patient interests should be prioritized. This maximizes healthcare value (quality divided by cost), simultaneously minimizing costs (objective) and maximizing quality (subjective). Unfortunately, even ‘high value’ procedures like total knee arthroplasty (TKA) suffer from recovery assessment subjectivity (i.e. high assessment variability) and increasing costs. High TKA costs and utilization yield high annual expenditures (∼$22B), including postoperative physical therapy (PT) accounting for ∼10% of total costs (∼$2.3B annually). Post-TKA PT is typically homogenous across subjects ensuring most recover, however recent work shows outcomes unimpacted by PT. Accordingly, opportunities exist improving healthcare value by simultaneously reducing unnecessary PT expenditures and improving outcomes. However, discerning recovery completion relies on discrete ROM measures captured clinically and subjective clinician experience (i.e. intuition about recovery). Accordingly, our goal was developing objective post-TKA performance assessment methods utilizing gait knee ROM and statistical analyses to categorize patient recovery (‘accelerated,’ ‘delayed,’ or ‘normal’).

Methods

We first established statistical reasons for current post-TKA rehabilitation including risk-reward tradeoffs between incorrectly ascribing ‘poor recovery’ to well-recovering patients (T1 error) or ‘good recovery’ to poorly-recovering patients (T2 error) using methods described by Mudge et al. and known TKA volumes/rehabilitation costs. Next, previously captured gait ROM data from well-healed patients was utilized establishing standard recovery curves. These were then utilized to assess newly captured patient recovery. Following IRB approval, we prospectively captured gait ROM from 10 TKA patients (3M, 69±13 years) 1-week pre-TKA and 6-weeks immediately post-TKA. Performance was compared to recovery curves via control charts/Shewhart rules (daily performance) as well as standard deviation thresholds (weekly performance) establishing recovery as ‘accelerated,’ ‘delayed,’ or ‘normal.’ The categorization was extrapolated to US TKA population and savings/expenses quantified. Statistical analyses were performed in Minitab with statistical significance set to α<0.05.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 26 - 26
1 Oct 2019
Dalury DF Chapman DM Miller MJ
Full Access

Introduction

Enhanced pain and rehabilitation protocols have significantly improved patient recovery following primary TKR. Little has been written on how the protocols have affected the revision TKR patient. We report on a matched group of revision and primary TKR patients treated with the identical pain and rehab program.

Materials and Methods

40 aseptic RTKR patients who underwent a full femoral and tibial revision were matched by age, sex, and BMI to a group of patients who underwent a cemented tri-compartmental primary TKR. All revision knees had uncemented stemmed femurs and tibias. All 40 patients had either a metaphyseal sleeve on either the femur or tibia or both. Patients in both groups were treated with an identical post op pain protocol (Spinal anesthetic, local infiltrative analgesia and multimodal oral pain management along with rapid rehabilitation). All patients were mobilized on POD1 and allowed weight bearing as tolerated. Patients were followed for a minimum of 1 year. KSS at 6 weeks and 1 year were recorded for both groups.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 104 - 107
1 Jul 2019
Greenwell PH Shield WP Chapman DM Dalury DF

Aims

The aim of this study was to establish the results of isolated exchange of the tibial polyethylene insert in revision total knee arthroplasty (RTKA) in patients with well-fixed femoral or tibial components. We report on a series of RTKAs where only the polyethylene was replaced, and the patients were followed for a mean of 13.2 years (10.0 to 19.1).

Patients and Methods

Our study group consisted of 64 non-infected, grossly stable TKA patients revised over an eight-year period (1998 to 2006). The mean age of the patients at time of revision was 72.2 years (48 to 88). There were 36 females (56%) and 28 males (44%) in the cohort. All patients had received the same cemented, cruciate-retaining patella resurfaced primary TKA. All subsequently underwent an isolated polyethylene insert exchange. The mean time from the primary TKA to RTKA was 9.1 years (2.2 to 16.1).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 75 - 75
1 Apr 2019
Lunn D Chapman G Redmond A
Full Access

Introduction

Total hip replacement (THR) patients are often considered a homogenous group whereas in reality, patients are heterogeneous. Variation in revision rates between patient groups suggest that implants are exposed to different environmental conditions in different patients [1]. Previous reports suggest that for every unit increase of BMI, there is a 2% increased risk of revision of a THR [2]. The aim of this study was to better understand the effect of patient-specific characteristics such as BMI on hip motions and to explore the possible impact on wear.

Methods

137 THR patients, at least 12 months post-surgery, underwent 3D kinematic (Vicon, Oxford, UK) and kinetic (AMTI, USA) analysis whilst walking at self-selected walking speed. 3D kinematic data were then mapped onto a modelled femoral cup at 20 pre-determined points to create pathways for femoral head contact, which were then quantified by deriving the aspect ratio (AR). Patients were stratified into three groups determined by BMI scores; healthy weight (BMI ≤25 kg/m2) (n=34); overweight (BMI >25kg/m2 to ≤ 30 kg/m2) (n=66) and obese patients (BMI > 30 kg/m2) (n=37). Comparisons were made using 95% confidence intervals (CI) and one way ANOVAs.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 76 - 76
1 Apr 2019
Vasiljeva K Al-Hajjar M Lunn D Chapman G Redmond A Flatters I Thompson J Jones A
Full Access

Introduction

One of the known mechanisms which could contribute to the failure of total hip replacements (THR) is edge contact. Failures associated with edge contact include rim damage and lysis due to altered loading and torques. Recent study on four THR patients showed that the inclusion of pelvic motions in a contact model increased the risk of edge contact in some patients. The aim of current study was to determine whether pelvic motions have the same effect on contact location for a larger patient cohort and determine the contribution of each of the pelvic rotations to this effect.

Methods

Gait data was acquired from five male and five female unilateral THR patients using a ten camera Vicon system (Oxford Metrics, UK) interfaced with twin force plates (AMTI) and using a CAST marker set. All patients had good surgical outcomes, confirmed by patient-reported outcomes and were considered well-functioning, based on elective walking speed. Joint contact forces and pelvic motions were obtained from the AnyBody modelling system (AnyBody Technologies, DK). Only gait cycle regions with available force plate data were considered. A finite element model of a 32mm head on a featureless hemispherical polyethylene cup, 0.5mm radial clearance, was used to obtain the contact area from the contact force. A bespoke computational tool was used to analyse patients' gait profiles with and without pelvic motions. The risk of edge contact was measured as a “centre proximity angle” between the cup pole and centre of the contact area, and “edge proximity angle” between the cup pole and the furthest contact area point away from the pole. Pelvic tilt, drop and internal-external rotation were considered one at a time and in combinations.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 15 - 15
1 Jan 2019
Rochelle D Herbert A Ktistakis I Redmond AC Chapman G Brockett CL
Full Access

Whilst lateral ankle sprain is often considered a benign injury it represents between 3–5% of all A&E visits in the UK. The mechanical characteristics of ankle ligaments under sprain-like conditions are scarcely reported.

The lateral collateral ankle ligaments were dissected from n=6 human cadaveric specimens to produce individual bone-ligament-bone specimens. An Instron Electropuls E10000 was used to uni-axially load the ankle ligaments in tension. The ligaments were first preconditioned between 2 N and a load value corresponding to 3.5% strain for 15 cycles and then strained to failure at a rate of 100%/s.

The mean ultimate failure loads and their standard deviations for the anterior talofibular (ATFL), calcaneofibular (CFL) and posterior talofibular (PTFL) ligaments are 351.4±105.6 N, 367.8±76.1 N and 263.6±156.6 N, respectively. Whilst the standard deviation values are high they align with those previously reported for ankle ligament characterisation. The large standard deviations are partly due to the inherent variability of human cadaveric tissue but could also be due to varying previous activity levels of participants or a prior unreported ankle sprain. Although the sample size is relatively small the results were stratified to identify any potential correlations of age, BMI and weight with ultimate load. A strong Pearson correlation (r=0.919) was found between BMI and ultimate load of the CFL but a larger sample size is required to confirm a link. The ligament failure modes were observed and categorised as avulsion or intra-ligamentous failure. The ATFL avulsed from the fibula in five instances and intra-ligamentous failure occurred once. The CFL avulsed from the fibula twice and failed four times through intra-ligamentous failure. Finally, the PTFL avulsed from the fibula once, avulsed from the talus once and failed through intra-ligamentous failure in four instances.

The results identify the forces required to severely sprain the lateral collateral ankle ligaments and their failure modes.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 33 - 33
1 Jan 2019
Hopwood J Chapman G Redmond A Richards L Brockett C
Full Access

Total ankle replacement (TAR) is a substitute to ankle fusion, replacing the degenerated joint with a mechanical motion-conserving alternative. Compared with hip and knee replacements, TARs remain to be implanted in much smaller numbers, due to the surgical complexity and low mid-to-long term survival rates. TAR manufacturers have recently explored the use of varying implant sizes to improve TAR performance. This would allow surgeons a wider scope for implanting devices for varying patient demographics. Minimal pre-clinical testing has been demonstrated to date, while existing wear simulation standards lack definition. Clinical failure of TARs and limited research into wear testing defined a need for further investigation into the wear performance of TARs to understand the effects of the kinematics on varying implant sizes.

Six medium and six extra small BOX® (MatOrtho) TARs will be tested in a modified knee simulator for 5 million cycles (Mc). The combinations of simulator inputs that mimic natural gait conditions were extracted from ankle kinematic profiles defined in previous literature. The peak axial load will be 3.15 kN, which is equivalent to 4.5 times body weight of a 70kg individual. The flexion profile ranges from 15° plantarflexion to 15° dorsiflexion. Rotation about the tibial component will range from −2.3° of internal rotation to 8° external rotation, while the anterior/posterior displacement will be 7mm anterior to −2mm posterior throughout the gait cycle. The components will be rotated through the simulation stations every Mc to account for inter-station variability. Gravimetric measurements of polyethylene wear will be taken at every Mc stage. A contact profilometer will also be used to measure average surface roughness of each articulating surface pre-and-post simulation.

The development of such methods will be crucial in the ongoing improvement of TARs, and in enhancing clinical functionality, through understanding the envelope of TAR performance.