We report the clinical and radiological outcomes
of a series of contemporary cementless ceramic-on-ceramic total hip
replacements (THRs) at ten years in patients aged ≤ 55 years of
age. Pre- and post-operative activity levels are described. A total
of 120 consecutive ceramic cementless THRs were performed at a single
centre in 110 patients from 1997 to 1999. The mean age of the patients
at operation was 45 years (20 to 55). At ten years, four patients
had died and six were lost to follow-up, comprising ten hips. The
mean post-operative Harris hip score was 94.7 (55 to 100). Radiological
analysis was undertaken in 90 available THRs of the surviving 106
hips at final review: all had evidence of stable bony ingrowth,
with no cases of osteolysis. Wear was undetectable. There were four
revisions. The survival for both components with revision for any
cause as an endpoint was 96.5% (95% confidence interval 94.5 to
98.7). The mean modified University of California, Los Angeles activity
level rose from a mean of 6.4 (4 to 10) pre-operatively to 9.0 (6
to 10) at the ten-year post-operative period. Alumina ceramic-on-ceramic bearings in cementless primary THR
in this series have resulted in good clinical and radiological outcomes
with undetectable rates of wear and excellent function in the demanding
younger patient group at ten years. Cite this article:
The success of total hip arthroplasty has meant its indications have been extended to the younger more active patient. Due to the higher activity levels and increased demands of these patients, revision rates have been traditionally higher than when compared to older patients [1]. Ceramic on ceramic bearings may offer a viable long term solution as manufacturing methods have evolved resulting in improved mechanical properties, particularly of third and fourth generation ceramics. We report the outcome of primary cementless, alumina-on-alumina hip arthroplasty with a minimum 10 year follow up in 110 patients under the age of 55 years of age at time of surgery. A series of 120 consecutive total hip arthroplasties in 110 patients were performed between June 1997 and February 1999 by the two senior authors. All patients had an Osteonics ABC acetabular component and SecurFit or SecurFit Plus femoral component (Stryker Orthopaedics, Mahwah, NJ) with an alumina C-taper ceramic head (Biolox Forte, Ceramtec, Plochingen, Germany).Introduction
Methods
Alumina ceramic on ceramic bearings in total hip arthroplasty (THA) may reduce the prevalence of osteolysis due to its properties of low wear and chemical inertness. This is critical in the younger patient population as they place increased demands over a longer period. This study reports on the clinical and radiographic outcomes of a series of modern cementless ceramic on ceramic THA at a minimum of 10 years in this younger group. A series of 120 consecutive third generation ceramic cementless THA were performed at a single centre in 110 patients from 1997 to 1999. The average age of the patients at the time of surgery was 45 years (20 to 55 years). All procedures were carried out via the posterior approach using the same implant by the two senior authors.Aim
Method
The Oxford Total Meniscal Knee (TMK by Biomet), is a total knee replacement with a multidirectional mobile bearing. As part of the evaluation of the TMK we compared our group of TMK knee replacements with an equivalent cohort of AGC total knee replacements. Patients recruited to AGC trial from 1994 to 2001. 254 AGC knee replacements sequentially recruited in 210 patients. Patients recruited to TMK trial from 2001 to 2007. 221 TMK knee replacements sequentially recruited in 193 patients. Patients prospectively randomised to having uncemented HA coated (HAC) or cemented versions in both groups. Each patient was reviewed pre-operatively, at 6 weeks, 6 months, 1 year and then annually. All AGC & TMK TKR's were assessed clinically using HSS scores and radiographically. TMK group also assessed using AKSS and OKQ scores.Introduction
Methods
Pseudotumours have been associated with metal-on-metal (MoM) hip replacements. We define it as a solid mass which may have cystic components that is neither neoplastic nor infectious in aetiology. The cause of a pseudotumour is not fully understood but could be due to excessive wear, metal hypersensitivity or due to an as-yet unknown cause. We present the retrieval analysis of early failure MoM hips revised for pain, loosening or a symptomatic mass. Tissues and implants were examined for the possible causes of failure and pseudotumour formation. Corrosion as a potential new cause for pseudotumour formation will be presented.Background
Aim
To evaluate safety and efficacy of performing a total knee arthroplasty (TKA) on patients receiving continuous Warfarin therapy We identified 24 consecutive patients receiving long term warfarin therapy who underwent total knee arthroplasty between 2006 and 2008. As a control, we collected the same data from a group of age and sex matched patients not on warfarin. Primary observations were changes in haemoglobin, transfusion rates and complications. Secondary observations were fluctuations in the INR and post operative range of motion (ROM). All procedures were performed by the senior author in a single centre using the same TKA technique.Aim
Methods
We report a case of a male patient presenting
with bilateral painful but apparently well-positioned and -fixed
large-diameter metal-on-metal hip replacements four years post-operatively.
Multiple imaging modes revealed a thick-walled, cystic expansile
mass in communication with the hip joint (a pseudotumour). Implant
retrieval analysis and tissue culture eliminated high bearing wear
or infection as causes for the soft-tissue reaction, but noted marked corrosion
of the modular neck taper adaptor and corrosion products in the
tissues. Therefore, we believe corrosion products from the taper
caused by mismatch of the implant components led to pseudotumour
formation requiring revision.
We evaluated the safety and efficacy of total
knee replacement in patients receiving continuous warfarin therapy. We identified 24 consecutive patients receiving long-term warfarin
therapy who underwent total knee replacement between 2006 and 2008
and compared them with a group of age- and gender-matched patients
not on long-term anticoagulation. Primary observations were changes
in haemoglobin, transfusion rates and complications. Secondary observations
were fluctuations in the international normalised ratio (INR) and
post-operative range of movement. There was no significant difference between the two groups in
pre- or post-operative haemoglobin, incidence of transfusion or
incidence of post-operative complications. There were no surgical
delays due to a high INR level. The mean change in INR during the
peri-operative phase was minimal (mean 0.4; Current American College of Chest Physicians guidelines recommend
bridging therapy for high-risk patients receiving oral anticoagulation
and undergoing major orthopaedic procedures. We have shown that
a safe alternative is to continue the steady-state warfarin peri-operatively
in patients on long-term anticoagulation requiring total knee replacement.
Development of a multidisciplinary care pathway and proforma following BOA Standards for Trauma (BOAST) and National Hip Fracture Database (NHFD) guidelines Re-audit of care following implementation of the proforma Identification of areas for development to implement in the NHS (Institute for Innovation and Improvement) Rapid Improvement Program – Focus on Fractured Neck of Femur
In June 2008 the proforma was implemented and data collected for reaudit (n=48). Direct comparison and statistical analysis was performed for the two groups of patients
A strong recommendation for gold standard care is the provision of an orthogeriatric service with regular medical review both pre- and post-operatively. Currently no such dedicated service exists at Maidstone and this affects both the treatment of acute medical problems and the provision of falls investigation and treatment. The introduction of the pathway has clearly benefitted the management of this difficult problem. With the support of the Rapid Improvement Program, further beneficial changes can be made to the care of patients following fractured NOF.
Clinical outcomes and radiographic analysis was performed. The Vancouver Classification was used to classify periprosthetic fracture. The MDI score was calculated using radiographs, as a control (gold standard), Yeung’s CBR score was calculated [4]. See Figure 1. A receiver operating characteristic (ROC) curve was formulated for both and area under the curve (AUC) compared. Intra and inter-observer correlations were determined. Cost analysis was also worked out.
62 periprosthetic fractures occurred in the uncemented group (15.2%), 9 in the cemented group (5.9%), p<
0.001. The revision rate for sustaining a periprosthetic fracture (uncemented group) was 17.7%, p<
0.001 and 90 day mortality 19.7%, p<
0.03. MDI’s AUC was 0.985 compared to CBR’s 0.948, p<
0.001. See Figure 2. The MDI score cut-off to predict fracture was 21, sensitivity 98.3%, specificity 99.8%, PPV 90.5%, NPV 98%. ANCOVA ruled out any other confounding factors as being significant. The intra and inter-observer Pearson correlation scores were r=0.99, p<
0.001. The total extra cost due to the intra-operative fractures was £93,780.
Various scoring systems are in use to assess the outcome of total hip replacement. Since its introduction in 1996, Oxford hip score (OHS) has been validated in several studies. Total hip replacement has been shown to improve the OHS in several studies but we could not find any studies on effect of the surgical approach on OHS.
We report the clinical and radiographic outcome of a consecutive series of 219 hydroxyapatite-coated total knee replacements with a follow-up of 5 to 8 years. Patients who fulfilled the entry criteria were included in a prospective study from early 1997 to late 1999. Regular clinical &
functional assessment was subsequently performed using the Knee Society Score, WOMAC &
SF-12 self-assessment questionnaires. Analysis of fluoroscopically controlled radiographs was performed using the American Knee Society Score. All living patients (186 knees) were followed-up. Exhaustive efforts were made to ensure that no patient was lost to follow-up. 28 patients (30 knees) were deceased. There have been 3 revisions. The mean pre-operative Knee Score of 43.8 increased to 77.1 and the mean pre-operative Function Score of 20.3 increased to 63.4 at 5 years. The WOMAC scores also showed marked improvement from pre-operative status after 5 years minimum follow-up: pain 250 pre-op to 157, stiffness 115 pre-op to 56 and function 910 pre-op to 588. There was no radiographic evidence of loosening or migration. The average American Knee Society Score for each component was 4. Small gaps between the bone-implant interface were observed to heal over the first year. A separate phenomenon of focal osteopenia is also described in a small number of well-fixed femoral components (12 of 219). To date, 3 prostheses have been revised, 2 due to deep infection and 1 due to tibial tray subsidence. A survivor-ship of 98.6% has been achieved at 8 years. We believe this to be the first medium term study for the Duracon HA coated knee arthroplasty system, showing excellent clinical and radiographic outcome, with 100% follow-up at 5 to 8 years.
Since 1986 the JRI Furlong hydroxyapatite coated femoral stem has been in use at our institution. We present the results of the first 100 hips performed on 86 patients by or under the direct supervision of one surgeon (JANS). The Furlong stem was used in conjunction with a ceramic head and CCI cemented UHDP cup. AT the time of surgery the mean age of the patients was 69 (range 45–94 years). One patient has undergone excision arthroplasty for suspected infection at which time the femoral component was found to be well bonded. At latest review, all patients were accounted for. 48 patients had died with no death directly related to surgery and no revisions or planned revision of the femoral component at the time of death. Of the 38 surviving patients (44 hips), the mean Merle d’Aubigné &
Postel score was 5.8 for pain, 5.7 for movement and 4.9 for function at 13 to 16.5 years follow up (mean 14.0). No femoral component showed radiological evidence of loosening. Five acetabular components have been revised for aseptic loosening with the femoral component found to be well bonded at the time of revision and therefore left in situ. In this series of hydroxyapatite coated femoral stems the overall revision rate is 1% with no cases of aseptic loosening. This hydroxyapatite coated prosthesis, at long term follow up has superior survival figures to other types of femoral components.
MRI is a well-tolerated, short procedure that would provide an early, accurate and cost effective diagnosis in elderly patients with negative plain films and persistent post-traumatic hip pain, thereby facilitating their correct management. It is 100% sensitive and specific to occult hip fractures and does not involve ionising radiation. Fractured necks of femur in the elderly population are common. This group of patients are responsible for a significant proportion of health care costs and efforts today. The diagnosis of hip fractures is not always clear-cut and plain radiographs may not show an undisplaced fracture. The management of this patient group is dependant upon the correct diagnosis via imaging and treatment decisions are based on these findings. If these fractures are missed, there is a significant chance of displacement and avascular necrosis presenting at a later date. This would complicate matters and result in more complex surgery. This also increases health care costs due to an extra admission, more expensive and difficult surgery with longer rehabilitation and after care. In our study, the management of the patients reviewed was significantly altered due to the imaging process used. We performed MRI scans on thirty-six patients who had post-traumatic hip pain and negative plain radiographs (reported as normal or equivocal). Twenty-three (64%) of the patients sustained a fracture, of which sixteen (44%) involved the neck of the femur, all of whom were above the age of 71 years. 100% of the elderly age group scanned were positive for a femoral neck fracture and eleven (31%) received operative intervention. The five patients who did not undergo operative management were deemed too unwell for surgery. Only three patients’ scans were negative. These results confirm that MRI (in the 71 years and above age group), is indicated in order to diagnose an undisplaced fractured neck of femur not recognised on plain radiographs, which requires operative intervention in the form of dynamic hip screw or cannulated hip screws to prevent further deterioration or displacement.