Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 13 - 13
1 Mar 2021
Chambers S Padmore C Fan S Grewal R Johnson J Suh N
Full Access

To determine the biomechanical effect of increasing scaphoid malunion and scaphoid non-union on carpal kinematics during dynamic wrist motion using an active wrist motion simulator.

Seven cadaveric upper extremities underwent active wrist flexion and extension in a custom motion wrist simulator with scaphoid kinematics being captured with respect to the distal radius. A three-stage protocol of progressive simulated malunion severity was performed (intact, 10° malunion, 20° malunion) with data analyzed from 45° wrist flexion to 45° wrist extension. Scaphoid malunions were modelled by creating successive volar wedge osteotomies and fixating the resultant scaphoid fragments with 0.062 Kirshner wires. At the completion of malunion motion trials, a scaphoid non-union trial was carried out by removing surgical fixation to observe motion differences from the malunion trials. Motion of the scaphoid, lunate, capitate, and trapezium-trapezoid was recorded and analyzed using active optical trackers.

Increasing scaphoid malunion severity did not significantly affect scaphoid or trapezium-trapezoid motion (p>0.05); however, it did significantly alter lunate motion (p<0.001). Increasing malunion severity resulted in progressive lunate extension across wrist motion (Intact – Mal 10: mean dif. = 7.1° ± 1.6, p<0.05; Intact – Mal 20: mean dif. = 10.2° ± 2.0, p<0.05;) although this change was not as great as the difference seen during non-union trials (native – non-union: mean dif. = 13.8° ± 3.7, p<0.05).

In this in-vitro model, increasing scaphoid malunion severity was associated with progressive extension of the lunate in all wrist positions. The clinical significance of this motion change is yet to be elucidated, but this model serves as a basis for understanding the kinematic consequences of scaphoid malunion deformities.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 204 - 204
1 Jan 2013
Chambers S Dowen D Muthumayandi K Mchutchon A Kramer D
Full Access

Introduction

Surgical spacesuits are in widespread use. Only one previous study (JBJS 1998) has assessed the quality of the environment within the space suit. They demonstrated that surgical spacesuits could allow re-breathing of carbon dioxide (CO2). However, they had no control group and performed a vigorous exercise protocol which may have been an unfair test. The design of helmet systems has also evolved in the last decade. We have conducted the first investigation into CO2 levels inside the modern space suit. There is a Workplace Exposure Limit for inspired CO2 as determined by the Health and Safety Executive (UK), which is 0.506kPa. We wondered whether re-breathing of CO2 in space suits would lead to inspired CO2 which breaches this level.

Methods

We used an anaesthetic room gas analyzer via nasal cannulae to measure inspired (ICO2) levels in 12 healthy volunteers. Readings were taken while wearing a surgical space suit with the fan on high and low settings. These were compared with a normal surgical facemask. Readings were repeated on mild exertion to simulate the effort of performing arthroplasty surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 81 - 81
1 Sep 2012
Locker J Hooper G Chambers S
Full Access

Determine if debridement, rather than staged revision is a more effective strategy in some patient subgroups with infected arthroplasty

We compiled a database comprising 154 proven infected knee replacements and 144 infected hip replacements in Christchurch over the last 10 years. This has given us the largest series in the literature. Cross referencing this database with the joint registry enabled us to compare the treatment of both acute and chronic infection in hip and knee arthroplasty with regard to both functional outcome and re-revision rate.

Patients treated with debridement had no statistically significant difference in re-revision rate or functional score when compared with patients undergoing staged revision.

Orthopaedic surgeons justifiably aim to eradicate infection in arthroplasty patients. A prosthesis retaining management strategy may be justifiable, especially in certain patient groups in whom multiple operations are best avoided.