Hip fractures cause significant morbidity and mortality, affecting 70,000 people in the UK each year. The dynamic hip screw (DHS) is used for the osteosynthesis of extracapsular neck of femur fractures, a procedure that requires complex psychomotor skills to achieve optimal lag screw positioning. The tip-apex distance (TAD) is a measure of the position of the lag screw from the apex of the femoral head, and is the most comprehensive predictor of cut-out (failure of the DHS construct). To develop these skills, trainees need exposure to the procedure, however with the European Working Time Directive, this is becoming harder to achieve. Simulation can be used as an adjunct to theatre learning, however it is limited. FluoroSim is a digital fluoroscopy simulator that can be used in conjunction with workshop bones to simulate the first step of the DHS procedure (guide-wire insertion) using image guidance. This study assessed the construct validity of FluoroSim. The null hypothesis stated that there would be no difference in the objective metrics recorded from FluoroSim between users with different exposure to the DHS procedure. This multicentre study recruited twenty-six orthopaedic doctors. They were categorised into three groups based on the number of DHS procedures they had completed as the primary surgeon (novice <10, intermediate 10≤x<40 and experienced ≥40). Twenty-six participants completed a single DHS guide-wire attempt into a workshop bone using FluoroSim. The TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR) were recorded for each attempt.Background
Methods
Training within surgery is changing from the traditional Halstedian apprenticeship model. There is need for objective assessment of trainees, especially their technical skills, to ensure they are safe to practice and to highlight areas for development. In addition, due to working time restrictions in both the UK and the US, theatre time is being limited for trainees, reducing their opportunities to learn such technical skills. Simulation is one adjunct to training that can be utilised to both assess trainees objectively, and provide a platform for trainees to develop their skills in a safe and controlled environment. The insertion of a dynamic hip screw (DHS) relies on complex psychomotor skills to obtain an optimal implant position. The tip-apex distance (TAD) is a measurement of this positioning, used to predict failure of the implant. These skills can be obtained away from theatre using workshop bone simulation, however this method does not utilise fluoroscopy due to the associated radiation risks. FluoroSim is a novel digital fluoroscopy simulator that can recreate digital radiographs with workshop bone simulation for the insertion of a DHS guide-wire. In this study, we present the training effect demonstrated on FluoroSim. The null hypothesis states that no difference will be present between users with different amounts of exposure to FluoroSim. Medical students were recruited from three London universities and randomised into a training (n=23) and a control (n=22) cohort. All participants watched a video explanation of the simulator and task and were blinded to their allocation. Training participants completed 10 attempts in total, 5 attempts in week one, followed by a one week wash out period, followed by 5 attempts in week 2. The control group completed a single attempt each week. For each attempt, 5 metrics were recorded; TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR).Background
Methods
Hip fractures affect 1.6 million people globally per annum, associated with significant morbidity and mortality. A large proportion are extracapsular neck of femur fractures, treated with the dynamic hip screw (DHS). Mechanical failure due to cut-out is seen in up to 7% of DHS implants. The most important predictor of cut-out is the tip-apex distance (TAD), a numerical value of the lag screw”s position in the femoral head. This distance is determined by the psychomotor skills of the surgeon guided by fluoroscopic imaging in theatre. With the current state of surgical training, it is harder for junior trainees to gain exposure to these operations, resulting in reduced practice. Additionally, methods of simulation using workshop bones do not utilise the imaging component due to the associated radiation risks. We present a digital fluoroscopy software, FluoroSim, a realistic, affordable, and accessible fluoroscopic simulation tool that can be used with workshop bones to simulate the first step of the DHS procedure. Additionally, we present the first round of accuracy tests with this software. The software was developed at the Royal National Orthopaedic Hospital, London, England. Two orthogonally placed cameras were used to track two coloured markers attached to a DHS guide-wire. Affine transformation matrices were used in both the anterior-posterior (AP) and cross table lateral (CTL) planes to match three points from the camera image of the workshop bone to three points on a pre-loaded hip radiograph. The two centre points of each marker were identified with image processing algorithms and utilised to digitally produce a line representing the guide-wire on the two radiographs. To test the accuracy of the system, the software generated 3D guide-wire apex distance (GAD) (from the tip of the guide-wire to a marker at the centre of calibration) was compared to the same distance measured with a digital calliper (MGAD). In addition, the same accuracy value was determined in a simulation scenario, from 406 attempts by 67 medical students.Background
Methods
The Royal National Orthopaedic Hospital has completed an extensive trial of ACI versus MACI in the treatment of symptomatic osteochondral defects of the knee. A new technique has now been proposed which is quicker and easier to perform. This is the Gel-Type Autologous Chondrocyte Transplantation, CHONDRONTM. At Stanmore CHONDRON has been used for the past 17 months. Our aim was to assess the short term functional outcome of patients who have undergone CHONDRONTM using validated outcome scoring questionnaires. We retrospectively reviewed the notes of 43 patients that had undergone CHONDRONTM over one year ago and scored them using the Modified Cincinnati Score, the Visual Analogue Score and the Benltey Stanmore Functional Rating Score. The mean pre-operative Modified Cincinnati Score was 39.9, which improved to a mean of 59.8 post-operatively. The mean Visual Analogue Score improved from 6.7 to 5.1 post-operatively. The median Bentley Functional Rating Score was 3 pre-operatively and 2 post-operatively. These early results show that 76% of the patients who were treated with CHONDRONTM experienced a reduction in pain and improvement in post-operative function. In the patients in whom the symptoms were worse, the deterioration in score could be partly explained by numerous previous procedures on the same site, presence of early osteoarthritis or the presence of multiple osteochondral lesions. This highlights the importance of careful patient selection in order to gain maximum benefit from the procedure.RESULTS
CONCLUSIONS
The aim of this study was to determine whether the clinical outcome of autologous chondrocyte transplantation was dependent on the timing of a high tibial osteotomy in tibio-femoral mal-aligned knees. Between 2000 and 2005, forty-eight patients underwent autologous chondrocyte implantation with HTO performed at varying times relative to the second stage autologous chondrocyte implantation procedure. 24 patients had HTO performed simultaneously with their second stage cartilage transplantation, (the HTO Simultaneous Group). 5 patients had HTO prior to their cartilage procedure, (the HTO pre-ACI Group) and 19 had HTO performed between 1 to 4 years after their second stage cartilage implantation, (the HTO post-ACI Group). There were 29 men and 19 women with a mean age of 37 years (Range 28 to 50) at the time of their second stage procedure. With average follow-up of 72 months we have demonstrated a significant functional benefit in performing the HTO either prior to or simultaneously with the ACI procedure in the mal-aligned knee. The failure rate in the Post-ACI group was 45% compared to the Pre-ACI and Simultaneous group, with failure rates of 20% and 25%, respectively. An HTO performed prior to or simultaneously with an autologous chondrocyte implantation procedure in the mal-aligned knee, provides a significant protective effect by reducing the failure rate by approximately 50%.
The aim of this study is to investigate whether MoM implants result in more chromosome aberrations and increased blood metal ions postoperatively whe compared to MoP implants. MoM arthroplasties are being inserted in increasing numbers of younger patients due to the increased durability and reduced requirements for revision in these implants. Recent studies have raised many concerns over possible genotoxicity of MoM implants. This is a prospective study of patients who have undergone elective total hip replacement, they were selected and then randomised into two groups. Group A received a MoP implant and group B received a MoM implant. Patients are reviewed pre-operatively (control group), at 3 months, 6 months, 1 year and 2 years post-operatively. On each occasion blood tests are taken to quantify metal ion levels (chromium, cobalt, titanium, nickel and vanadium) using HR-ICPMS method and chromosome aberrations in T lymphocytes using 24 colour fluorescent in situ hydridisation (FISH). 51 patients have been recruited to date, 23 of whom had MoP prosthesis and 28 a MoM. 47 of these had their 1 year follow-up with blood analysis and 38 have had 2 year follow up. There appeared to be a bedding period for both MoM and MoP groups, with an increase in metal ion release. The blood concentration of chromium, cobalt and titanium rise significantly in the MoM group at the 2 year stage. Chromosome aberrations occurred in both groups. Both the MoM and MoP groups showed increase frequency of aneuploidy aberrations and structural damage. The greatest increase in metal ion levels occurred at the 1 to 2 year interval corresponding to significant rise in chromosome aberrations. Preliminary results of this study show that the levels of chromium, cobalt and titanium are significantly higher in the MoM group compared to the MoP group. This corresponds to increases in chromosome aberrations in the groups with increases in structural chromosome damage after two years.
The position of the hip-joint centre of rotation (HJC) within the pelvis is known to influence functional outcome of total hip replacement (THR). Superior, lateral and posterior relocations of the HJC from anatomical position have been shown to be associated with greater joint reaction forces and a higher incidence of aseptic loosening. In biomechanical models, the maximum force, moment-generating capacity and the range of motion of the major hip muscle groups have been shown to be sensitive to HJC displacement. This clinical study investigated the effect of HJC displacement and acetabular cup inclination angle on functional performance in patients undergoing primary THR. Retrospective study of primary THR patients at the RNOH. HJC displacement from anatomical position in horizontal and vertical planes was measured relative to radiological landmarks using post-operative, calibrated, anterior-posterior pelvic radiographs. Acetabular cup inclination angle was measured relative to the inter-teardrop line. Maximum range of passive hip flexion, abduction, adduction, external and internal rotation were measured in clinic. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model.Background
Methods
Autologous chondrocyte implantation (ACI) is contra-indicated in a joint rendered unstable by a ruptured anterior cruciate ligament (ACL). We present our experience of ACI repair with ACL reconstruction Patients underwent arthroscopic examination and cartilage harvesting of the knee. A second operation was undertaken approximately six weeks later to repair the ruptured ACL with hamstring graft or Bone patella-Bone (BPB) and to implant the chondrocytes via formal arthrotomy. Three groups were assessed: Group 1: Simultaneous ACL Reconstruction and ACI; Group 2: Previous ACL Reconstruction with subsequent ACI repair; Group 3: Previously proven partial or complete ACL rupture, deemed stable and not treated with reconstruction with ACI procedure subsequently. Patients then underwent a graduated rehabilitation program and were reviewed using three functional measurements: Bentley functional scale, the modified Cincinnati rating system, and pain measured on a visual analogue scale. All patients also underwent formal clinical examination at review.Introduction
Methods
It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome. Retrospective study of primary THR patients at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant musculoskeletal radiologist in both coronal and sagittal planes using post-operative anterior-posterior and lateral pelvic radiographs. Each THR was grouped into valgus, minor-valgus, neutral, minor-varus or varus coronal plane alignment and posterior, minor-posterior, neutral, minor-anterior or anterior sagittal plane alignment. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model. 90 THRs were studied in 87 patients (55 Female). Mean age at THR=62 (22-86). Mean follow-up=17 months (11-39 months). Median OHS=16, WOMAC=8. Coronal plane alignment of the femoral stem was not associated with any change in OHS (p>0.05) or WOMAC score (p>0.05). Sagittal plane alignment of the femoral stem was not associated with any change in OHS (p>0.05) or WOMAC score (p>0.05).Methods
Results
Articular cartilage implantation (ACI) and associated procedures (MACI = Matrix-assisted cartilage implantation) are now established treatments for osteochondral defects in the knee. The quality of repair in terms of histological appearance is frequently not known, whilst the correlation of histology results with functional outcomes remains undefined. Histological data of the quality of the repair tissue is sparse and a precise classification proved difficult. This was a single-centre, prospective study. Over 12 years (1998-2010) 406 patients that underwent articular cartilage implantation procedures at our institution (ACI = 170, MACI = 205) had biopsies taken at the 1-2 year interval, in order to assess whether these contained ‘hyaline-like’ cartilage, ‘mixed hyaline-like with fibrocartilage’, fibrocartilage or fibrous tissue alone. Histological sections of the biopsies were prepared and stained with haematoxylin, eosin and proteoglycan stains and viewed under polarised light. All biopsies were studied by a single histopathologist in a specialist, dedicated musculoskeletal laboratory. All patients were assessed by the Cincinnati, Bentley and Visual Analogue scores both pre-operatively and at the time of the review. The findings revealed that 56 patients healed with ‘hyaline-like’ cartilage (14.9%), 103 with ‘mixed’ (27.5%), 179 with fibrocartilage (47.7%) and 37 with fibrous tissue (9.9%). These findings showed that 42.4% of defects were filled with ‘hyaline-like’ or ‘mixed’ cartilage, with 70% of these achieving a ‘fair’ to ‘excellent’ functional outcome. This was also observed in the fibrocartilage group, where 72% achieved similar results. Predictably 89% of the patients that healed by fibrous tissue had a poor functional outcome. This study shows that 71% of patients whose osteochondral defects healed by either ‘hyaline-like’, ‘mixed’ or fibrocartilage experienced an improvement in the function. In contrast, only 11% of the patients whose defects filled with fibrous tissue, showed some functional improvement. Additionally, this data indicates the advantage of biopsies in assessing the overall results of cartilage implantation procedures.