Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_27 | Pages 19 - 19
1 Jul 2013
Rashid M Butt U Birch A Crank S Temperley D Freemont A Trail I
Full Access

Our aim was to accurately determine whether muscle atrophy and fatty infiltration are reversible following cuff repair. Patients with a repairable cuff-tear were recruited and assessed clinically and radiologically (Magnetic Resonance Imaging). At surgery, supraspinatus was biopsied. Post-operatively, patients underwent clinical evaluation at standardised intervals, with further MRI and an ultrasound guided biopsy of supraspinatus at 12 months.

MRI was used to characterize cuff-tears and determine the degree of muscle atrophy and fatty infiltration. Biopsy samples were fixed on-site and transported for processing. Morphometric assessments of myofibres were made and mean cross-sectional areas calculated using validated techniques. The pathologist was blinded to sample details. Statistical analysis was performed to assess differences in mean myofibre area following cuff repair and correlated with radiological findings.

Eight patients were available for completed histological and radiological analysis. Six (two re-tears) demonstrated sizeable and highly statistically significant improvements in mean myofibre cross-sectional area (P=0.000–0.0253). Of the two not showing any increase in myofibre area, neither result was statistically significant (P=0.06, 0.2); one was a re-tear and one was a repair of a partial-thickness tear. Radiologically, the muscle and fatty changes had not demonstrably changed.

Our finding that myofibre cross-sectional area increases following cuff repair suggests muscle atrophy is a potentially reversible process. Even with re-tears, improvements were seen. MRI features of fatty infiltration and muscle atrophy were not seen to improve however. It is likely that radiological assessment is not sensitive enough to demonstrate the reversibility of muscle atrophy seen on histological analysis at one year.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 190 - 190
1 Jan 2013
Alazzawi S Bardakos N Hadfield G Butt U Beer Z Field R
Full Access

Using general practitioner records, hospital medical notes and through direct telephone conversation with patients, we investigated the accuracy of nine patient-reported complications after elective joint replacement surgery of the hip and knee. A total of 402 post-discharge complications were reported after 8546 elective operations that were undertaken within a three-year period. These were reported by 136 men and 240 women with an overall mean age of 71.8 years (34.3–93.2). A total of 319 (79.4%; 95% confidence interval, 75.4%–83.3%) reported complications were confirmed to be correct. Very high rates of correct reporting were demonstrated for infection (94.5%) and further surgery (100%), whereas the rates of reporting deep venous thrombosis (DVT), pulmonary embolism, myocardial infarct and stroke were lower (75%–84.2%). Dislocation, periprosthetic fractures and nerve palsy were associated with modest rates of correct reporting (36%–57.1%). More patients who had had knee surgery delivered incorrect reports of dislocation (p = 0.001) and DVT (p = 0.013). Despite these variations in accuracy, it appears that post-operative complications may form part of a larger patient-reported outcome programme for monitoring outcome after elective joint replacement surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIX | Pages 3 - 3
1 May 2012
Butt U Ahmad R Aspros D Bannister G
Full Access

Wound ooze is common following Total Knee Arthroplasty and persistent wound ooze is a risk factor for infection, increased length and cost of hospitalisation. We undertook a prospective study to assess the effect of tourniquet time, periarticular local anaesthesia and surgical approach on wound oozing after TKA. The medial parapatellar approach was used in 59 patients (77%) and subvastus in 18 patients (23%). Periarticular local anaesthesia (0.25% Bupivacaine with 1:1000000 adrenalin) was used in 34 patients (44%). The mean tourniquet time was 83 minutes (range 38 to 125 minutes). We found a significant association between cessation of oozing and periarticular local anaesthesia (P = 0.003), length of the tourniquet time (P = 0.03) and the subvastus approach (P = 0.01). Periarticular local anaesthesia, the subvastus approach and shorter tourniquet time were all associated with less wound oozing after total knee arthroplasty.