The aim of the study was to characterise gait in patients with achondroplasia post lengthening. Full kinematic and kinetic lower limb gait analysis was performed at the Sheffield Children's Hospital gait laboratory, Sheffield, using a Vicon system (6 cameras working at 50Hz) and processed using Plug In Gait modelling software. The lengthened Achondroplasia group (n=11, mean age = 24.5 ± 6.1) had previously undergone surgical lengthening of the legs. The lengthened Achondroplasia group was compared to a control group of 11 adult normal subjects.Aim
Patients/Materials and Methods
To examine the effect of limb lengthening on the quality of life of people who have disproportionate short stature (DSS). Thirteen previous patients, completed the SF-36, the Derriford Appearance Scale and participated in face to face semi structured interviews to establish the impact on their physical and social functioning, their present situation including employment, education, housing and leisure activities and their thoughts about whether they felt the treatment had been worthwhile. To increase understanding about the patient and family experience of limb lengthening, participants were asked about their memories of the procedure and the treatment period.Purpose
Method
. There is less information on normal foetal hip . Magnetic resonance imaging (MRI) allows development to be followed in the healthy baby.
To establish normal patterns of hip development. To obtain charts that could be used to detect abnormality earlier. There are three aspects to this study:
Validation – analysing MRI scans of babies hips prior to post mortem (the gold standard) would verify MRI as a valid tool for such studies. Measurements will be gained for foetus in utero Similarly for pre and term babies.
For the initial validation process, parents who had consented to post mortem were asked to consider additionally an MR scan of their neonate’s hips, a total of 30 cases.
Measurements were made, by two independent observers, of the width and depth of the acetabulum and the radius &
diameter of the femoral head, volume and area were calculated. Inter-observer variation was assessed.
With the exception of the acetabular width each dimension showed little development until week 20 when the line of growth rose exponentially. The acetabular width showed only a slow rate of growth despite the changes seen in the femoral head. Levels of observer agreement were high (ICCs = 0.98) for all but depth (ICCs = 0.86). The measurements for all dimensions were in line with previous post mortem studies.
To establish normal patterns of hip development. To obtain charts that could be used to detect abnormality earlier. There are three aspects to this study:
Validation – analysing MRI scans of babies hips prior to post mortem (the gold standard) would verify MRI as a valid tool for such studies. Similarly for a) fetuses in utero b) pre and term babies.
For the initial validation process, parents who had consented to post mortem were asked to consider additionally an MR scan of their neonate’s hips, a total of 30 cases.
Measurements were made, by two independent observers, of the width and depth of the acetabulum and the radius &
diameter of the femoral head, volume and area were calculated. Inter-observer variation was assessed.
With the exception of the acetabular width each dimension showed little development until week 20 when the line of growth rose exponentially. The acetabular width showed only a slow rate of growth despite the changes seen in the femoral head. Levels of observer agreement were high (ICCs 95% = 0.98) for all but depth (ICCs 95% = 0.86). The measurements for all dimensions were in line with previous post mortem studies.
HHS:Mean pre-arthroplasty score 47 (range 10–73), 1 yr score 99 (n=38), 2yr 97.3 (n=30) at 3yr 100 (n=26) &
4th yr 100 (n=4), this shows a statistically signiþcant improvement (P=0.001). WOMAC: Pain: pre-op score 18.8, at 1 year 5.6 &
2nd year 5.7. Stiffness: pre-op 8.5, 1 year 2.7 &
2nd year 2.7. Physical: 49.3, 1 year 23.4 &
2nd year 22.6. This shows a statistically signiþcant improvement in score (p=0.025) SF-36 Analysed against an age/sex match control group of normal values using a 2 tailed Ôtñ Test, seven of the eight domains showed no statistical signiþcant difference.
Fine-wire accepted as a minimally external fixation is invasive technique, which can provide better outcomes than traditional open methods in the management of complex fractures of the tibial plateau. Available fixators vary in their biomechanical stability, and we believe that a stable beam-loading system is essential for consistently good outcomes. We assessed, prospectively, the clinical, radiological and general health status of 20 of 21 consecutive patients with complex fractures of the tibial plateau who had been treated using a standard protocol, with percutaneous screw fixation and a neutralisation concept with a fine wire beam-loading fixator allowing early weight-bearing. Bony union was achieved in all patients, with 85% having good or excellent results. Full weight-bearing started during the first six weeks in 60% of patients. The general health status assessment correlated well with the knee scores and reflected a satisfactory outcome.
To review the early functional results of Birmingham hip resurfacing. First 116 hips (98 patients), a cohort of consecutive patients prospectively underwent BHR in a single arthroplasty Surgeon’s practice in a University Hospital outside Birmingham. Inclusion criteria fit and active patients. 98 patients mean age 50 years (range 19–67). Pathology OA 85%, Perthes 7%, DDH 4.7% &
SUFE 2%. Mean follow-up 30 months (range 12–45). Scoring systems used were Harris hip score (HHS), WOMAC &
SF36. HHS: mean pre-arthroplasty 47 (range 10–73), one year 99 (n=57), at 2 years 97.3 (n=26) and at third year 100 (n=3), statistically significant improvement (P=0.001). WOMAC: pain: pre-op score 18.8, at 1 year 5.6 and second year 5.7. Stiffness: pre-op 8.5, 1 year 2.7 &
2nd year 2.7. Physical: 49.3, 1 year 23.4 &
2nd year 22.6. This shows a statistically significant improvement in pain score (p=0.025) and physical function score (p=0.025).
One fracture following a fall (patient had deep cysts in proximal head now such patients are not offered BHR), one dislocation following RTA and one AVN in a 50 years old post menopausal lady. Birmingham hip resurfacing can provide excellent level of activity and patient satisfaction. A long-term study is needed to evaluate the long-term benefit and survivorship.
To assess the outcome of bicondylar tibial fractures, treated prospectively with fine wire fixation in the Limb Reconstruction Service. Twenty patients with mean age 56 years with bicondylar tibial plateau fractures, were treated at the author’s institution with fine wire fixation over a three-year period. Ten followed road traffic accidents and four followed high-energy falls; The remainder mainly in the elderly resulted from a simple fall. There were four Schatzeker type V, and sixteen type VI. Four were open fractures (Gustilo grade III); Seven patients sustained associated fractures at the same time. They were treated according to a prospective protocol and were followed up for an average of thirty months, (11 – 51). The protocol included CT Scan Guided planning, closed reduction if possible and percutaneous interfragmentary screw fixation to reconstruct the articular surface, under image intensifier control; The external fixator was applied in neutralization. Mobilization and full weight bearing was encouraged as early as possible Ten patients started full weight bearing between four and six weeks post operatively, in nine cases with other injuries weight bearing was delayed. All patients healed with an average time in the fixator of eighteen weeks, (9–25). Fifteen patients had a range of movement from Zero to at least 120 degrees flexion. Using Rasmussen’s functional and radiological scoring system, fifteen out of twenty scored good or excellent. Complications included deep vein thrombosis in one patient, loss of fracture reduction in three, superficial pin tract infection which resolved with local pin care and a short courses of antibiotic in five patients, there was no deep infection. The Sheffield hybrid external fixator is strong, permits early fracture recovery and weight bearing and may have significantly contributed to the high rate of good results in this group, of which more than 50% were over sixty years old. This technique is recommended for treatment of this difficult fracture.