header advert
Results 1 - 1 of 1
Results per page:
Applied filters
Foot & Ankle

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_21 | Pages 1 - 1
1 Apr 2013
Hossain N Budgen M
Full Access

Minimally invasive chevron and akin osteotomy are being used in a few centres in the UK. The purpose of our study was to analyse our early results and present our early experience of minimally invasive chevron and akin osteotomy (MICA) for the correction of mild to moderate hallux valgus.

This study assessed the radiological and clinical measurements, American Orthopaedic Foot and Ankle Society (AOFAS) scores, pain scores and patient satisfaction associated with performance of the MICA, for the treatment of hallux valgus.

Between September 2010 and April 2012, 96 consecutive patients (122 feet) who underwent MICA were assessed. The overall satisfaction rate was over 90%. The mean total AOFAS score was 89.7 points. VAS for pain reduced from a mean of 7.4 to less than 1 point. On weight bearing anterior-posterior foot radiographs there was a significant improvement in the mean IMA and HVA.

Complications included 2 episodes of superficial infection (1.6%), 1 fracture (0.8%), 4 incidence of nerve injury (3.3%) (Numbness) and 9 patients requiring removal of screw (7.4%). However, these screw removals occurred early on in the study and diminished after a slight modification in surgical technique.

Based on our findings we concluded that MICA is an effective procedure with good patient satisfaction in the treatment of mild to moderate hallux valgus.